Comparison of radiographic and functional results of die-punch fracture of distal radius between volar locking plating (VLP) and external fixation (EF)

被引:15
|
作者
Zhou, Yanqing [1 ,2 ]
Zhu, Yanbin [3 ]
Zhang, Xiong [1 ,2 ]
Tian, Dehu [1 ,2 ]
Zhang, Bing [1 ,2 ]
机构
[1] Hebei Med Univ, Dept Hand Surg, Hosp 3, Shijiazhuang 050051, Hebei, Peoples R China
[2] Key Lab Biomech Hebei Prov, Shijiazhuang 050051, Hebei, Peoples R China
[3] Hebei Med Univ, Dept Orthopaed Trauma Ctr, Hosp 3, Shijiazhuang 050051, Hebei, Peoples R China
关键词
Die-punch fracture; Distal radius; Radiographic and functional outcome; Volar plate fixation; External fixation; INTERNAL-FIXATION; COMPLICATIONS; DORSAL; EPIDEMIOLOGY; LUNATE;
D O I
10.1186/s13018-019-1442-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of this study is to investigate the radiographic and functional results of die-punch fracture of distal radius treated by volar locking plate (VLP) or external fixation (EF). Methods Between January 2015 and June 2018, 87 patients who were treated with EF or VLP were included in this study. At postoperative 6 months and at least 12 months, radiographic and functional outcomes were evaluated, and compared between two groups using SPSS 21.0. Results The follow-up period was 15.6 months in average, and at the mean 8.5 weeks bony union was achieved in all patients. At 6-month visit, patients in VLP group had significantly better wrist flexion (79.2 degrees vs. 71.8 degrees) and pronation (79.5 degrees vs. 75.2 degrees) than those in EF group, but the difference was non-significant at the last visit (> 12 months); as for other parameters, no significant differences were observed. No significant difference was found between both groups in term of volar tilt, radial inclination, radial height, ulnar variance, or Gartland-Werley score and DASH. The articular step-off was significantly greater in EF than VLP group (0.6 mm vs. 0.3 mm, p < 0.001). The overall incidence of complications seemed higher in EF group (25% vs. 14%), but not approaching to the statistical significance level. Conclusions Patients with VLP fixation of die-punch fractures had better wrist flexion and pronation at 6-month visit and more favorable wrist joint congruence at the last visit, but ultimately their outcome was comparable with those treated by EF.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Evaluation of radiographic fracture position 1 year after variable angle locking volar distal radius plating: a prospective multicentre case series
    Teunis, T.
    Jupiter, J.
    Schaser, K. D.
    Fronhoefer, G.
    Babst, R.
    Langer, M.
    Platz, A.
    Schierz, A.
    Joeris, A.
    Rikli, D.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2017, 42 (05) : 493 - 500
  • [22] Comparison between Volar Locking Plate and Kirschner Wire Fixation for Unstable Distal Radius Fracture: A Meta-Analysis of Randomized Controlled Trials
    Tariq, Muhammad A.
    Ali, Uzair
    Uddin, Qazi S.
    Altaf, Zahabia
    Mohiuddin, Ashar
    JOURNAL OF WRIST SURGERY, 2024, 13 (05) : 469 - 480
  • [23] Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a meta-analysis
    Walenkamp, Monique M. J.
    Bentohami, Abdelali
    Beerekamp, M. Suzan H.
    Peters, Rolf W.
    van der Heiden, Remy
    Goslings, J. Carel
    Schep, Niels W. L.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2013, 8 (02) : 67 - 75
  • [24] Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
    Kumbaraci M.
    Kucuk L.
    Karapinar L.
    Kurt C.
    Coskunol E.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 173 - 178
  • [25] Comparison Between External Fixators and Fixed-Angle Volar-Locking Plates in the Treatment of Distal Radius Fractures
    Agustin Jorge-Mora, Alberto
    Cecilia-Lopez, David
    Rodriguez-Vega, Victor
    Suarez-Arias, Laura
    Andres-Esteban, Eva
    Porras-Moreno, Miguel Angel
    Resines-Erasun, Carlos
    JOURNAL OF HAND AND MICROSURGERY, 2012, 4 (02) : 50 - 54
  • [26] Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
    Yin-Ming Huang
    Chun-Yu Chen
    Kai-Cheng Lin
    Yih-Wen Tarng
    Ching-Yi Liao
    Wei-Ning Chang
    BMC Musculoskeletal Disorders, 23
  • [27] Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
    Huang, Yin-Ming
    Chen, Chun-Yu
    Lin, Kai-Cheng
    Tarng, Yih-Wen
    Liao, Ching-Yi
    Chang, Wei-Ning
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [28] Comparison of volar locking plates with external fixation and K-wires in arthroscopically assisted intra-articular distal radial fracture fixation
    Krustins, Uldis
    Krustins, Janis
    Bringina, Diana
    Laurane, Kristine
    Jumtins, Andris
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (04) : 333 - 338
  • [29] A Volar Locking Plate With Fossa Specific Fixation Provides Comparable Stability Between Articular and Nonarticular Cadaveric Models of Distal Radius Fracture
    Heifner, John J.
    McIver, Natalia D.
    Salas, Christina
    Mercer, Deana M.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024, 19 (03): : 464 - 470
  • [30] COMPARISON BETWEEN CAST IMMOBILIZATION VERSUS VOLAR LOCKING PLATE FIXATION OF DISTAL RADIUS FRACTURES IN ACTIVE ELDERLY PATIENTS, THE ASIAN PERSPECTIVE
    Chan, Ying-Ho
    Foo, Tun-Lin
    Yeo, Chong-Jin
    Chew, Winston Yoon-Chong
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2014, 19 (01): : 19 - 23