Structural and material mechanical properties of human vertebral cancellous bone

被引:81
|
作者
Nicholson, PHF
Cheng, XG
Lowet, G
Boonen, S
Davie, MWJ
Dequeker, J
Van der Perre, G
机构
[1] Katholieke Univ Leuven, Div Biomech & Engn Design, B-3001 Louvain, Belgium
[2] Katholieke Univ Leuven, Arthrit & Metab Bone Dis Res Unit, B-3001 Louvain, Belgium
[3] Robert Jones & Agnes Hunt Orthopaed Hosp, Charles Salt Res Ctr, Oswestry SY10 7AG, Shrops, England
关键词
cancellous bone; vertebra; mechanical properties; anisotropy; ultrasound;
D O I
10.1016/S1350-4533(97)00030-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The structural Young's modulus (i.e. that of the cancellous framework) was determined by non-destructive compressive mechanical testing in the the ee orthogonal ax es of 48 vertebral bone cubes. In addition, the material Young's modulus (i.e. of the trabeculae themselves) was estimated using an ultrasonic technique. Apparent and true density were determined by direct physical measurements. Significant mechanical anisotropy was observed: mean structural Young's modulus varied from 165 MPa in the supero-inferior direction to 43 MPa in the lateral direction. Structural Young's modulus correlated with apparent density, with power-law regression models giving the best correlations (r(2) = 0.52-0.88). Mechanical anisotropy increased as a function of decreasing apparent density (p < 0.001). Material Young's modulus was 10.0 +/- 1.3 GPa, and was negatively correlated with apparent density (p < 0.001). In multiple regression models, material Young's modulus was a significant independent predictor of structural Young's modulus only in the supero-inferior direction. The data suggest the presence of two effects in vertebral bone associated with decreasing apparent density and, by implication, bone loss in general: (a) increased mechanical anisotropy such that there is relative conservation of stiffness in the axial direction compared with the transverse directions; and (b) increased stiffness of the trabeculae themselves. (C) 1997 IPEM Published by Elsevier Science Ltd.
引用
收藏
页码:729 / 737
页数:9
相关论文
共 50 条
  • [1] Relationships Among Bone Morphological Parameters and Mechanical Properties of Cadaveric Human Vertebral Cancellous Bone
    Al-Barghouthi, Abeer
    Lee, Seokgi
    Solitro, Giovanni Francesco
    Latta, Loren
    Travascio, Francesco
    JBMR PLUS, 2020, 4 (05)
  • [2] Mechanical and structural anisotropy of human cancellous femur bone
    Nikodem, A.
    Bedzinski, R.
    Scigala, K.
    Dragan, S.
    JOURNAL OF VIBROENGINEERING, 2009, 11 (03) : 571 - 576
  • [3] DYNAMIC MECHANICAL-PROPERTIES OF HUMAN CANCELLOUS BONE
    FITZGERALD, ER
    HUNGERFORD, DS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (03): : 190 - 190
  • [4] MECHANICAL-PROPERTIES OF MICROCALLUS IN HUMAN CANCELLOUS BONE
    BLACKBURN, J
    HODGSKINSON, R
    CURREY, JD
    MASON, JE
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (02) : 237 - 246
  • [5] FAILURE MECHANISMS IN HUMAN VERTEBRAL CANCELLOUS BONE
    FYHRIE, DP
    SCHAFFLER, MB
    BONE, 1994, 15 (01) : 105 - 109
  • [6] PROPORTION OF HUMAN VERTEBRAL BODY BONE THAT IS CANCELLOUS
    EASTELL, R
    MOSEKILDE, L
    HODGSON, SF
    RIGGS, BL
    JOURNAL OF BONE AND MINERAL RESEARCH, 1990, 5 (12) : 1237 - 1241
  • [7] HUMAN VERTEBRAL CANCELLOUS BONE SURFACE DISTRIBUTION
    FYHRIE, DP
    LANG, SM
    HOSHAW, SJ
    SCHAFFLER, MB
    KUO, RF
    BONE, 1995, 17 (03) : 287 - 291
  • [8] Anatomical variation of human cancellous bone mechanical properties in vitro
    Hobatho, MC
    Rho, JY
    Ashman, RB
    BONE RESEARCH IN BIOMECHANICS, 1997, 40 : 157 - 173
  • [9] Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic
    Wang, SJ
    JOURNAL OF BIOMECHANICS, 2002, 35 (04) : 549 - 549
  • [10] Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic
    Giesen, EBW
    Ding, M
    Dalstra, M
    van Eijden, TMGJ
    JOURNAL OF BIOMECHANICS, 2001, 34 (06) : 799 - 803