A numerical study on the oil retention of R410A and PVE oil mixture in multi heat pump system

被引:2
|
作者
Kim, Hak Soo [1 ]
Kim, Min Soo [1 ]
机构
[1] Seoul Natl Univ, Dept Mech & Aerosp Engn, Seoul 151744, South Korea
基金
新加坡国家研究基金会;
关键词
Flow pattern; Lubricant; Multi heat pump system; Oil retention; PVE oil; R410A; FRICTION CHARACTERISTICS; GENERAL CORRELATION; FLOW; EXCHANGERS; PIPE;
D O I
10.1007/s12206-016-0348-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Predicting an amount of discharged oil from a compressor is necessary to charge the compressor with proper amount of oil. The amount of discharged oil can be predicted by calculating the oil retention amount in each component of a heat pump system. This study suggests a method for calculating the oil retention amount in a heat pump system. In addition, flow pattern of refrigerant and oil mixture in horizontal gas line of refrigerant was ascertained by flow visualization. The oil retention amounts in each component of multi heat pump system were calculated with respect to mass flux of refrigerant, Oil circulation ratio (OCR), length of horizontal and vertical lines. Oil retention amounts in horizontal and vertical gas lines of refrigerant were significant. To validate the model for gas lines of refrigerant, comparison between predicted and experimental oil retention amounts was conducted, and mean absolute percentage error was 15.0%.
引用
收藏
页码:1891 / 1901
页数:11
相关论文
共 50 条
  • [31] Life cycle climate performance of R410A and its environmentally friendly alternative working fluids in a heat pump system
    Zhang, Yong
    Yang, Zhao
    Chen, Yubo
    He, Hongxia
    Zhao, Yanfeng
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2024, 71
  • [32] Numerical simulation of heat transfer performance of R410A in condensing-superheated zone
    Zhang, Lu
    Liu, Jinping
    Xu, Xiongwen
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 128 : 206 - 217
  • [33] Experimental analysis on heat exchanger's condensation and evaporation characteristics of R410A heat pump in winter condition
    Wang, F.
    Wu, Z. M.
    Liu, Y.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 922 - 927
  • [34] COMPARATIVE EXPERIMENTAL RESEARCHES OF AIR-TO-WATER HEAT PUMP WITH R32 AND R410A FOR HOUSEHOLD
    Huang, Y.
    Yin, Q.
    Yu, J.
    Wang, J.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 796 - +
  • [35] Performance comparison of evaporator with circuit number change in heat pump using R22 and R410A
    Huang, Dong
    Li, Quanxu
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2009, 43 (07): : 58 - 62
  • [36] PERFORMANCE CHARACTERISTICS OF AIR SOURCE GAS ENGINE-DRIVEN HEAT PUMP SYSTEM WITH R410A REFRIGERANT FOR COOLING APPLICATION
    Hu Y.
    Lyu J.
    Han T.
    Tian J.
    Song W.
    Feng Z.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (03): : 401 - 408
  • [37] Effects of component performance on overall performance of R410A air conditioner with oil flooding and regeneration
    Luo, Baojun
    ENERGY CONVERSION AND MANAGEMENT, 2016, 110 : 192 - 199
  • [38] Heat transfer characteristics of flow boiling of R410A-oil mixture in a 7 mm enhanced tube
    Institute of Refrigeration and Cryogenics Engineering, Shanghai Jiaotong University, Shanghai 200240, China
    不详
    Huagong Xuebao, 2008, 1 (32-37):
  • [39] Numerical and experimental investigation on nozzle parameters for R410A ejector air conditioning system
    Hu, Jichao
    Shi, Junye
    Liang, Yuanyuan
    Yang, Zijiang
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 40 : 338 - 346
  • [40] Optimal temperature between high and low stage cycles for R134a/R410A cascade heat pump based water heater system
    Kim, Dong Ho
    Park, Han Saem
    Kim, Min Soo
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 47 : 172 - 179