Seismic performance of semi-precast composite columns with bolted end-plate connections to footing

被引:2
|
作者
Kim, Chang-Soo [1 ]
Jo, Woo-Bin [1 ]
Baek, Seon-Woo [1 ]
Hwang, Hyeon-Jong [2 ]
机构
[1] Seoul Natl Univ Sci & Technol, Sch Architecture, 232 Gongreung Ro, Seoul 01811, South Korea
[2] Konkuk Univ, Sch Architecture, 120 Neungdong Ro, Seoul 05029, South Korea
基金
新加坡国家研究基金会;
关键词
Semi-precast; Composite column; Quasi-static; Bolted end-plate connection; Perforated shear connector;
D O I
10.1016/j.engstruct.2022.114174
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To improve manufacturability in factories, constructability on-site, and structural performance at ultimate states, a new method for semi-precast composite columns was developed using corner steel angles and internal moulds. To verify the proposed method, full-scale mockup testing and quasi-static testing were performed for five column specimens with bolted end-plate connections to the footing. Test parameters included joint details and shear connectors. The test results showed that, although a monolithic column specimen exhibited better performance, overall, the semi-precast composite columns with the connections also showed satisfactory behavior in terms of lateral strength, stiffness, displacement capacity, and energy dissipation. The test results were compared with the predictions by numerical analysis and current design codes assuming a fully rigid joint and full composite action. The numerical analysis results and calculated design strength agreed well with the test results, which implies that current design methods are applicable to the design of the proposed column method.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A study on semi-continuous composite beams with realistic modelling of end-plate connections
    Wang, A.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2012, 13 (03) : 259 - 277
  • [42] Seismic performance of precast RC and RC/ECC composite columns with grouted sleeve connections
    Xu, Li
    Pan, Jinlong
    Cai, Jingming
    ENGINEERING STRUCTURES, 2019, 188 : 104 - 110
  • [43] Seismic performance experiments on semi-precast shear wall-frame structures
    Ma, Junwei
    Pan, Jinlong
    Mo, Chuang
    Yin, Wanyun
    Liu, Shoucheng
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2017, 47 (02): : 313 - 319
  • [44] Seismic performance of semi-precast high-strength recycled aggregate concrete columns with high-strength reinforcement
    Zhang, Jianwei
    Tao, Xinyi
    Liu, Juan
    Dong, Hongying
    Cao, Wanlin
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [45] 'Heavy' moment end-plate connections subjected to seismic loading
    Sumner, EA
    Mays, TW
    Murray, TM
    BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2000, : 735 - 740
  • [46] Calibration of a finite element model for isolated bolted end-plate steel connections
    Bursi, OS
    Jaspart, JP
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1997, 44 (03) : 225 - 262
  • [47] Behavior of extended end-plate bolted connections subjected to monotonic and cyclic loads
    ElSabbagh, Ashraf
    Sharaf, Tarek
    Nagy, Salah
    ElGhandour, Mohammed
    ENGINEERING STRUCTURES, 2019, 190 : 142 - 159
  • [48] SEISMIC SIMULATION ON STEEL BEAM TO CONCRETE FILLED DOUBLE-SKINNED STEEL TUBULAR COLUMN COMPOSITE FRAME WITH BOLTED END-PLATE CONNECTIONS
    He, Wen-Hui
    Wang, Zhan
    Wu, Qi-Peng
    Huang, Jia-Pu
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 439 - 444
  • [49] Structural performance evaluation of bolted end-plate connections in a half-through railway inclined girder
    Kim, Jung Hyun
    Shim, Chang Su
    STEEL AND COMPOSITE STRUCTURES, 2023, 49 (05): : 473 - 486
  • [50] Behavior of I-beam bolted extended end-plate moment connections
    Dessouki, Abdelrahim Khalil
    Youssef, Ahmed Hassan
    Ibrahim, Mohamed Mostafa
    AIN SHAMS ENGINEERING JOURNAL, 2013, 4 (04) : 685 - 699