Seismic performance of semi-precast composite columns with bolted end-plate connections to footing

被引:2
|
作者
Kim, Chang-Soo [1 ]
Jo, Woo-Bin [1 ]
Baek, Seon-Woo [1 ]
Hwang, Hyeon-Jong [2 ]
机构
[1] Seoul Natl Univ Sci & Technol, Sch Architecture, 232 Gongreung Ro, Seoul 01811, South Korea
[2] Konkuk Univ, Sch Architecture, 120 Neungdong Ro, Seoul 05029, South Korea
基金
新加坡国家研究基金会;
关键词
Semi-precast; Composite column; Quasi-static; Bolted end-plate connection; Perforated shear connector;
D O I
10.1016/j.engstruct.2022.114174
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To improve manufacturability in factories, constructability on-site, and structural performance at ultimate states, a new method for semi-precast composite columns was developed using corner steel angles and internal moulds. To verify the proposed method, full-scale mockup testing and quasi-static testing were performed for five column specimens with bolted end-plate connections to the footing. Test parameters included joint details and shear connectors. The test results showed that, although a monolithic column specimen exhibited better performance, overall, the semi-precast composite columns with the connections also showed satisfactory behavior in terms of lateral strength, stiffness, displacement capacity, and energy dissipation. The test results were compared with the predictions by numerical analysis and current design codes assuming a fully rigid joint and full composite action. The numerical analysis results and calculated design strength agreed well with the test results, which implies that current design methods are applicable to the design of the proposed column method.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Structural behavior of end-plate bolted connections to stiffened columns
    Bahaari, MR
    Sherbourne, AN
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (08): : 926 - 935
  • [2] Structural behavior of end-plate bolted connections to stiffened columns
    Univ of Waterloo, Canada
    J Struct Eng, 8 (926-935):
  • [3] Seismic performance of prefabricated composite frame beam-column joints with grouted end-plate bolted connections
    Zhang X.
    Ma X.
    Zhang S.
    Li Q.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 101 - 111
  • [4] Behaviour of bolted end-plate connections to concrete-filled steel columns
    Tao, Zhong
    Li, Wei
    Shi, Bo-Lin
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 134 : 194 - 208
  • [5] Seismic Performance of Precast Columns with Mechanically Spliced Column-Footing Connections
    Haber, Zachary B.
    Saiidi, M. Saiid
    Sanders, David H.
    ACI STRUCTURAL JOURNAL, 2014, 111 (03) : 639 - 650
  • [6] Seismic behavior of concrete shear walls with bolted end-plate DfD connections
    Ding, Tao
    Xiao, Jianzhuang
    Wei, Kaihua
    Lu, Yujie
    ENGINEERING STRUCTURES, 2020, 214
  • [7] Experimental investigation of bolted end-plate angle splice in encased composite columns
    Eom, Tae-Sung
    Yang, Jong-Min
    Kim, Dae-Kyeong
    Lim, Jong-Jin
    Lee, Seung-Hwan
    ENGINEERING STRUCTURES, 2019, 190 : 31 - 40
  • [8] Fire resistance of axially loaded semi-precast composite columns
    Truong, Gia Toai
    Baek, Seon-Woo
    Im, Ho
    Kim, Chang-Soo
    STRUCTURES, 2024, 59
  • [9] Nonlinear response of bolted end-plate steel connections
    Amiri, GG
    Jamalzadeh, M
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 77 - 82
  • [10] Seismic behaviour of high-strength steel bolted extended end-plate connections
    Hu, Fangxin
    Wang, Zhan
    ce/papers, 2023, 6 (3-4) : 639 - 644