Comparison of real-time tracking & 4D inverse planning for managing patient respiratory motion

被引:0
|
作者
Zhang, P. [1 ]
Yan, D. [1 ]
Hugo, G. [1 ]
机构
[1] William Beaumont Hosp, Royal Oak, MI 48072 USA
关键词
D O I
10.1118/1.2760367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Real‐time tracking and 4D‐planning at the mean target position have been two potential methodologies to manage respiratory target motion. In this study, we evaluated each method based on dose‐volume criteria of organs in lung cancer radiotherapy. Method and Materials: Four patients with respiratory target excursions 1.5cm to 3.0cm were included. Each patient had 4D‐CT scans at 10 breathing phases. Deformable organ registration was applied to obtain subvolume displacement mapping for each phase of CT image. First, an idealized real‐time tracking technique was evaluated assuming perfect estimation of target motion and beam tracking. Inverse planning was performed on each breathing phase CT image without using margins for target and normal structures. Treatment dose was accumulated from does of each breathing phase. Secondly, a 4D‐inverse planning was performed on the mean 4D‐CT image using the corresponding pdf of respiratory motion created from the 4D‐CTs. Same beams and prescription dose (70Gy), as well as same objective and constraints, were applied in the planning optimization, and the cumulative dose was constructed accordingly. DVH and EUD in the GTV, lung, heart and cord were used for the evaluation. Results: Cumulative doses in target are similar for both techniques. The beam intensity modulation in the 4D inverse planning is much higher than the one in the real‐time tracking, but it can be delivered using beam compensator. Lung, heart and cord DVHs are similar with the corresponding EUDs, 4.6±2.2Gy, 8.3±4.6Gy and 11±4.35Gy for the tracking technique, and 5.3±2.3Gy, 8.8±5.1Gy and 11.9±5.0Gy for the 4D inverse planning. Conclusion: Treatment technique with the 4D‐inverse planning and online mean target position control is clinically practical. Compared to the idealized real‐time tracking, 4D‐inverse planning achieves slightly degraded, but similar. However, this degradation could be vanished when practical tracking error was considered. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2335 / 2336
页数:2
相关论文
共 50 条
  • [41] Comparison of Respiratory Motion Suppression Techniques for 4D Flow MRI
    Dyverfeldt, Petter
    Ebbers, Tino
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1877 - 1882
  • [42] 4D treatment planning: Calculation of voxel doses in the presence of respiratory motion
    Rietzel, E
    Chen, GTY
    Choi, NC
    Willett, CG
    MEDICAL PHYSICS, 2004, 31 (06) : 1751 - 1751
  • [43] Radar Tracking of Respiratory Motion in Real Time
    Fung, A.
    Li, C.
    Torres, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3858 - 3858
  • [44] Real-time crowd motion planning
    Yersin, Barbara
    Maiem, Jonathan
    Morini, Fiorenzo
    Thalmann, Daniel
    VISUAL COMPUTER, 2008, 24 (10): : 859 - 870
  • [45] Quick Low Dose 4D CBCT: Real Patient Results of Respiratory Motion Guided Imaging and Motion Compensated Reconstruction
    Dillon, O.
    Lau, B.
    Alnaghy, S.
    Keall, P.
    Vinod, S.
    Wallis, A.
    Smith, S.
    George, A.
    Sonke, J.
    O'Brien, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E312 - E312
  • [46] Real-time tracking for managing suburban intersections
    Veeraraghavan, H
    Masoud, O
    Papanikolopoulos, N
    DSP 2002: 14TH INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING PROCEEDINGS, VOLS 1 AND 2, 2002, : 1023 - 1026
  • [47] Method of real-time tracking for respiratory motion based on SIFT feature matching
    Feng, Dong
    Sun, Li-Ning
    Ru, Chang-Hai
    Information Technology Journal, 2013, 12 (16) : 3897 - 3902
  • [48] Real-time respiratory motion tracking: Roadmap correction for hepatic artery catheterizations
    Atasoy, Selen
    Groher, Martin
    Zikic, Darko
    Glocker, Ben
    Waggershauser, Tobias
    Pfister, Marcus
    Navab, Nassir
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [49] The comparative performance of four respiratory motion predictors for real-time tumour tracking
    Krauss, A.
    Nill, S.
    Oelfke, U.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5303 - 5317
  • [50] Real-Time Target Tracking Prostate SBRT and the Real-Time Tracking System 4D Localization System: 5-Year Quality of Life and Disease Outcomes
    Mantz, C. A.
    Fernandez, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S393 - S393