VIRTUAL ENTEROSCOPY USING AIR AS THE CONTRAST MATERIAL: A PRELIMINARY FEASIBILITY STUDY

被引:7
|
作者
Endo, Kazuhiro [2 ]
Utano, Kenichi [1 ,3 ]
Togashi, Kazutomo [1 ,2 ]
Yano, Tomonori [1 ]
Lefor, Alan T. [2 ]
Yamamoto, Hironori [1 ]
Yasuda, Yoshikazu [2 ]
Sugimoto, Hideharu [3 ]
机构
[1] Jichi Med Univ, Dept Endoscopy, Shimotsuke, Tochigi 3290498, Japan
[2] Jichi Med Univ, Dept Surg, Shimotsuke, Tochigi 3290498, Japan
[3] Jichi Med Univ, Dept Radiol, Shimotsuke, Tochigi 3290498, Japan
关键词
computed tomography enteroclysis; intestinal neoplasms; three-dimensional image; virtual endoscopy; virtual enteroscopy; MULTIDETECTOR CT ENTEROCLYSIS; CROHNS-DISEASE; ENTEROGRAPHY;
D O I
10.1111/j.1443-1661.2010.00986.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: There are no studies to date using air as an enteral contrast medium for small bowel expansion in virtual enteroscopy. We examine the feasibility of air as an enteral contrast medium for virtual enteroscopy to achieve small bowel expansion. Patients and Methods: Two volunteers and six patients were examined. The six patients included three with small bowel tumors, one with small bowel hemorrhage and two with suspected cases of post-operative small bowel stenosis. A duodenal tube was inserted under fluoroscopy and approximately 2000 ml air was administered prior to scanning. A 16-detector row computed tomography apparatus was used with 2-mm thick slices. Intravenous contrast material was administered to the patients, but not to the volunteers. Computed tomography scanning was performed two to three times until the air reached the colon. Two examiners reconstructed multi-planar reformation, volume rendering and virtual endoscopy. These images were compared with double balloon enteroscopic findings and/or resected specimens. Results: There were no complications associated with this examination. In the volunteers the difference between the circular folds of the jejunum and those of the ileum was clearly visualized on virtual endoscopy. Angiodysplasia (9 mm), gastrointestinal stromal tumor (15 mm) and arteriovenous malformation were clearly detected by virtual endoscopy. In contrast, one tumor could not be detected because of inadequate intestinal distension. In the two suspected cases of the stenosis, the lesion was not identified because stenotic lesions were not differentiated from normal peristalsis of the small bowel. Conclusions: Air is a feasible enteral contrast material for virtual enteroscopy.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [31] Colorectal neoplasm detection using virtual colonoscopy: a feasibility study
    Fenlon, HM
    Nunes, DP
    Clarke, PD
    Ferrucci, JT
    GUT, 1998, 43 (06) : 806 - 811
  • [32] Preliminary feasibility study of an in-line phase contrast X-ray imaging prototype
    Zhang, Da
    Donovan, Molly
    Fajardo, Laurie L.
    Archer, Ann
    Wu, Xizeng
    Liu, Hong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (09) : 2249 - 2257
  • [33] The Feasibility Study of Dual -Energy CT Virtual Non Contrast instead of True Non -Contrast in Proton Radiotherapy Dose Calculation
    Qu, G.
    Zhu, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E781 - E781
  • [34] Feasibility study of using porous metal as practical shielding material
    See, K. Y.
    Ling, Y.
    Koh, W. J.
    Ma, J.
    Ho, S. F.
    2008 ASIA-PACIFIC SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND 19TH INTERNATIONAL ZURICH SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, 2008, : 451 - +
  • [35] FEASIBILITY STUDY AND PRELIMINARY DESIGN
    MORTIMER, JM
    CANADIAN MINING AND METALLURGICAL BULLETIN, 1968, 61 (672): : 489 - &
  • [36] Preliminary Feasibility Study of Quantum Key Distribution for Future Air Traffic Management Systems
    Kanada, Naoki
    Lu, Xiaodong
    2023 IEEE 15TH INTERNATIONAL SYMPOSIUM ON AUTONOMOUS DECENTRALIZED SYSTEM, ISADS, 2023, : 167 - 170
  • [37] Using Virtual Reality for Industrial Robot Programming: A Preliminary Study
    Chang, Yi-hsiang
    Devine, Kevin
    Klitzing, Gunnar
    JOURNAL OF ENGINEERING TECHNOLOGY, 2021, 38 (01) : 34 - 44
  • [38] Feasibility of spiral enteroscopy in Japanese patients: Study in two tertiary hospitals
    Yamada, Atsuo
    Watabe, Hirotsugu
    Oka, Shiro
    Kogure, Hirofumi
    Imagawa, Hiroki
    Kobayashi, Yuka
    Suzuki, Hirobumi
    Watari, Ikue
    Aoyama, Taiki
    Isayama, Hiroyuki
    Yamaji, Yutaka
    Fujishiro, Mitsuhiro
    Tanaka, Shinji
    Koike, Kazuhiko
    DIGESTIVE ENDOSCOPY, 2013, 25 (04) : 406 - 411
  • [39] First multicenter clinical study on feasibility of spiral enteroscopy for japanese patients
    Yamada, Atsuo
    Watabe, Hirotsugu
    Oka, Shiro
    Kogure, Hirofumi
    Imagawa, Hiroki
    Koabayashi, Yuka
    Suzuki, Hirobumi
    Watari, Ikue
    Aoyama, Taiki
    Isayama, Hiroyuki
    Yamaji, Yutaka
    Fujishiro, Mitsuhiro
    Tanaka, Shinji
    Koike, Kazuhiko
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 395 - 395
  • [40] MR virtual colonography using hyperpolarized 3He as an endoluminal contrast agent:: Demonstration of feasibility
    Hagspiel, KD
    Altes, TA
    Mugler, JP
    Spellman, MJ
    Mata, JF
    Tustison, NJ
    Brookeman, JR
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (05) : 813 - 816