VIRTUAL ENTEROSCOPY USING AIR AS THE CONTRAST MATERIAL: A PRELIMINARY FEASIBILITY STUDY

被引:7
|
作者
Endo, Kazuhiro [2 ]
Utano, Kenichi [1 ,3 ]
Togashi, Kazutomo [1 ,2 ]
Yano, Tomonori [1 ]
Lefor, Alan T. [2 ]
Yamamoto, Hironori [1 ]
Yasuda, Yoshikazu [2 ]
Sugimoto, Hideharu [3 ]
机构
[1] Jichi Med Univ, Dept Endoscopy, Shimotsuke, Tochigi 3290498, Japan
[2] Jichi Med Univ, Dept Surg, Shimotsuke, Tochigi 3290498, Japan
[3] Jichi Med Univ, Dept Radiol, Shimotsuke, Tochigi 3290498, Japan
关键词
computed tomography enteroclysis; intestinal neoplasms; three-dimensional image; virtual endoscopy; virtual enteroscopy; MULTIDETECTOR CT ENTEROCLYSIS; CROHNS-DISEASE; ENTEROGRAPHY;
D O I
10.1111/j.1443-1661.2010.00986.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: There are no studies to date using air as an enteral contrast medium for small bowel expansion in virtual enteroscopy. We examine the feasibility of air as an enteral contrast medium for virtual enteroscopy to achieve small bowel expansion. Patients and Methods: Two volunteers and six patients were examined. The six patients included three with small bowel tumors, one with small bowel hemorrhage and two with suspected cases of post-operative small bowel stenosis. A duodenal tube was inserted under fluoroscopy and approximately 2000 ml air was administered prior to scanning. A 16-detector row computed tomography apparatus was used with 2-mm thick slices. Intravenous contrast material was administered to the patients, but not to the volunteers. Computed tomography scanning was performed two to three times until the air reached the colon. Two examiners reconstructed multi-planar reformation, volume rendering and virtual endoscopy. These images were compared with double balloon enteroscopic findings and/or resected specimens. Results: There were no complications associated with this examination. In the volunteers the difference between the circular folds of the jejunum and those of the ileum was clearly visualized on virtual endoscopy. Angiodysplasia (9 mm), gastrointestinal stromal tumor (15 mm) and arteriovenous malformation were clearly detected by virtual endoscopy. In contrast, one tumor could not be detected because of inadequate intestinal distension. In the two suspected cases of the stenosis, the lesion was not identified because stenotic lesions were not differentiated from normal peristalsis of the small bowel. Conclusions: Air is a feasible enteral contrast material for virtual enteroscopy.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [1] Feasibility study of using air as a contrast medium in MR colonography
    So, NMC
    Lam, WWM
    Mann, D
    Leung, KL
    Metreweli, C
    CLINICAL RADIOLOGY, 2003, 58 (07) : 555 - 559
  • [2] Computed tomographic enteroclysis with air and virtual enteroscopy: Protocol and feasibility for small bowel evaluation
    Yoshikawa, Toshiyuki
    Takehara, Yasuo
    Kikuyama, Masataka
    Takeuchi, Ken
    Hanai, Hiroyuki
    DIGESTIVE AND LIVER DISEASE, 2012, 44 (04) : 297 - 302
  • [3] Targeting of ultrasound contrast material - An in vitro feasibility study
    Klibanov, AL
    Hughes, MS
    Marsh, JN
    Hall, CS
    Miller, JG
    Wible, JH
    Brandenburger, GH
    ACTA RADIOLOGICA, 1997, 38 : 113 - 120
  • [4] Detection of small-bowel tumours with CT enteroclysis using carbon dioxide and virtual enteroscopy: A preliminary study
    Dohan, Anthony
    Boudiaf, Mourad
    Dray, Xavier
    Samaha, Elia
    Cellier, Christophe
    Camus, Marine
    Eveno, Clarisse
    Dautry, Raphael
    Soyer, Philippe
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 206 - 213
  • [5] Detection of small-bowel tumours with CT enteroclysis using carbon dioxide and virtual enteroscopy: A preliminary study
    Anthony Dohan
    Mourad Boudiaf
    Xavier Dray
    Elia Samaha
    Christophe Cellier
    Marine Camus
    Clarisse Eveno
    Raphael Dautry
    Philippe Soyer
    European Radiology, 2018, 28 : 206 - 213
  • [6] Simulation of aortic peak enhancement on MDCT using a contrast material flow phantom: Feasibility study
    Awai, K
    Hatcho, A
    Nakayama, Y
    Kusunoki, S
    Liu, D
    Hatemura, M
    Funama, Y
    Denbo, M
    Sato, N
    Yamashita, Y
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) : 379 - 385
  • [7] Development of contrast-enhanced virtual MR cholangioscopy: a feasibility study
    P. Prassopoulos
    N. Papanikolaou
    T. Maris
    C. Gogas
    J. Mouzas
    N. Gourtsoyiannis
    European Radiology, 2002, 12 : 1438 - 1441
  • [8] Development of contrast-enhanced virtual MR cholangioscopy: a feasibility study
    Prassopoulos, P
    Papanikolaou, N
    Maris, T
    Gogas, C
    Mouzas, J
    Gourtsoyiannis, N
    EUROPEAN RADIOLOGY, 2002, 12 (06) : 1438 - 1441
  • [9] PRELIMINARY STUDY OF THE FEASIBILITY OF AN AIR CUSHION VEHICLE SIMULATOR.
    Band, D.
    UTIAS Technical Note (University of Toronto, Institute for Aerospace Studies), 1974, (189):
  • [10] DOUBLE CONTRAST PYLORIC RADIOLOGY BY AIR INSUFFLATION . PRELIMINARY STUDY
    NIKOLOV, PN
    BARLIJEV, BG
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1968, 109 (05): : 623 - &