On the long-term stability of terrestrial reference frame solutions based on Kalman filtering

被引:3
|
作者
Soja, Benedikt [1 ]
Gross, Richard S. [1 ]
Abbondanza, Claudio [1 ]
Chin, Toshio M. [1 ]
Heflin, Michael B. [1 ]
Parker, Jay W. [1 ]
Wu, Xiaoping [1 ]
Nilsson, Tobias [2 ]
Glaser, Susanne [2 ]
Balidakis, Kyriakos [2 ]
Heinkelmann, Robert [2 ]
Schuh, Harald [2 ,3 ]
机构
[1] CALTECH, Jet Prop Lab, Pasadena, CA 91125 USA
[2] GFZ German Res Ctr Geosci, Potsdam, Germany
[3] Tech Univ Berlin, Inst Geodesy & Geoinformat Sci, Berlin, Germany
基金
美国国家航空航天局;
关键词
Terrestrial reference frame; Kalman filter; VLBI; NONLINEAR STATION MOTIONS; LINE INTERFEROMETRY; REALIZATION; ITRF2014;
D O I
10.1007/s00190-018-1160-0
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The Global Geodetic Observing System requirement for the long-term stability of the International Terrestrial Reference Frame is 0.1 mm/year, motivated by rigorous sea level studies. Furthermore, high-quality station velocities are of great importance for the prediction of future station coordinates, which are fundamental for several geodetic applications. In this study, we investigate the performance of predictions from very long baseline interferometry (VLBI) terrestrial reference frames (TRFs) based on Kalman filtering. The predictions are computed by extrapolating the deterministic part of the coordinate model. As observational data, we used over 4000 VLBI sessions between 1980 and the middle of 2016. In order to study the predictions, we computed VLBI TRF solutions only from the data until the end of 2013. The period of 2014 until 2016.5 was used to validate the predictions of the TRF solutions against the measured VLBI station coordinates. To assess the quality, we computed average WRMS values from the coordinate differences as well as from estimated Helmert transformation parameters, in particular, the scale. We found that the results significantly depend on the level of process noise used in the filter. While larger values of process noise allow the TRF station coordinates to more closely follow the input data (decrease in WRMS of about 45%), the TRF predictions exhibit larger deviations from the VLBI station coordinates after 2014 (WRMS increase of about 15%). On the other hand, lower levels of process noise improve the predictions, making them more similar to those of solutions without process noise. Furthermore, our investigations show that additionally estimating annual signals in the coordinates does not significantly impact the results. Finally, we computed TRF solutions mimicking a potential real-time TRF and found significant improvements over the other investigated solutions, all of which rely on extrapolating the coordinate model for their predictions, with WRMS reductions of almost 50%.
引用
收藏
页码:1063 / 1077
页数:15
相关论文
共 50 条
  • [31] Frame-based subband Kalman filtering for speech enhancement
    Wu, Wen-Rong
    Chen, Po-Chen
    Chang, Hwai-Tsu
    Kuo, Chun-Hung
    International Conference on Signal Processing Proceedings, ICSP, 1998, 1 : 682 - 685
  • [32] On the stability of a geodetic no-net-rotation frame and its implication for the International Terrestrial Reference Frame
    Kreemer, Corne
    Lavallee, David A.
    Blewitt, Geoffrey
    Holt, William E.
    GEOPHYSICAL RESEARCH LETTERS, 2006, 33 (17)
  • [33] Long-term stability of diluted solutions of the monoclonal antibody rituximab
    Paul, Muriel
    Vieillard, Victoire
    Jaccoulet, Emmanuel
    Astier, Alain
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2012, 436 (1-2) : 282 - 290
  • [34] LONG-TERM STABILITY STUDY OF HISTAMINE IN STERILE BRONCHOPROVOCATION SOLUTIONS
    MARWAHA, RK
    JOHNSON, BF
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1986, 43 (02): : 380 - 383
  • [35] pH, conductivity and long-term stability in the Crystal Screen solutions
    Bukrinsky, JT
    Poulsen, JCN
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2001, 34 : 533 - 534
  • [36] LONG-TERM SOLUTIONS
    IVEY, SK
    SOUTH DAKOTA FARM & HOME RESEARCH, 1981, 32 (01): : 17 - 19
  • [38] LONG-TERM STABILITY
    GOLDEMBERG, RL
    DRUG & COSMETIC INDUSTRY, 1988, 143 (05): : 26 - 26
  • [39] Long-Term Stability of Reference Measuring System for Impulse High Voltage
    Miyazaki, Satoru
    Goshima, Hisashi
    Wakimoto, Takayuki
    Ishii, Masaru
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2022, 17 (03) : 369 - 377
  • [40] Frame of reference for the elaboration of policies for long-term care .1. constituent elements
    Beland, F
    Arweiler, D
    CANADIAN JOURNAL ON AGING-REVUE CANADIENNE DU VIEILLISSEMENT, 1996, 15 (04): : 597 - 631