Construction of graphene oxide sheets based modified glassy carbon electrode (GO/GCE) for the highly sensitive detection of nitrobenzene

被引:32
|
作者
Ahmad, Khursheed [1 ]
Mohammad, Akbar [1 ]
Ansari, Shagufi Naz [1 ]
Mobin, Shaikh M. [1 ,2 ,3 ]
机构
[1] Indian Inst Technol Indore, Discipline Chem, Khandwa Rd, Indore 453552, Madhya Pradesh, India
[2] Indian Inst Technol Indore, Discipline Biosci & Biomed Engn, Khandwa Rd, Indore 453552, Madhya Pradesh, India
[3] Indian Inst Technol Indore, Discipline Met Engn & Mat Sci, Khandwa Rd, Indore 453552, Madhya Pradesh, India
来源
MATERIALS RESEARCH EXPRESS | 2018年 / 5卷 / 07期
关键词
graphene oxide; glassy carbon electrode; nitrobenzene sensor; cyclic voltammetry; METAL-ORGANIC FRAMEWORK; ELECTROCHEMICAL SENSOR; REDUCTION; PERFORMANCE; STORAGE; FACILE;
D O I
10.1088/2053-1591/aacd98
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Herein, we have demonstrated the role of simple graphene oxide (GO) sheets as electrocatalyst for the voltammetric detection of nitrobenzene (NBz). GO was synthesized from natural graphite flakes and characterized by PXRD, FE-SEM, FTIR and UV-vis spectroscopy. A binder free electrochemical sensor by modifying active surface area of glassy carbon electrode (GO/GCE) was developed using simple drop casting method. The electrochemical behavior of the developed sensor towards NBz was examined extensively using cyclic voltammetry (CV), linear sweep voltammetry (LSV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV). The modified GO/GCE sensor showed a limit of detection (LOD) of 66 nM by CV, 79 nM by LSV, 146 nM SWV and 135 nM and corresponding sensitivity of 157.14 mu A mu M-1 cm(-2),297.21 mu A mu M-1 cm(-2),677.14 mu A mu(-1) cm(-2) and 1216.71 mu A mu M-1 cm(-2) were observed by CV, LSV, DPV and SWV respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Fabrication of Sulfur-Doped Reduced Graphene Oxide Modified Glassy Carbon Electrode (S@rGO/GCE) Based Acetaminophen Sensor
    Khan, Mohd Quasim
    Kumar, Praveen
    Khan, Rais Ahmad
    Ahmad, Khursheed
    Kim, Haekyoung
    INORGANICS, 2022, 10 (12)
  • [42] Application of graphene oxide sheets incorporated in the porous calcium alginate films on the glassy carbon electrode for biosensor construction based on myoglobin
    Ma, Qianqian
    Sun, Hong
    Hou, Shifeng
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2013, 43 (10) : 975 - 984
  • [43] Sensitive Electrochemical Detection of Dopamine With a Nitrogen-doped Graphene Modified Glassy Carbon Electrode
    Wang, Wencheng
    Gong, Shixing
    Sun, Wei
    Li, Guangjiu
    Lu, Yaping
    Yu, Jianhua
    Dong, Lifeng
    CROATICA CHEMICA ACTA, 2016, 89 (03) : 323 - 330
  • [44] Application of graphene oxide sheets incorporated in the porous calcium alginate films on the glassy carbon electrode for biosensor construction based on myoglobin
    Qianqian Ma
    Hong Sun
    Shifeng Hou
    Journal of Applied Electrochemistry, 2013, 43 : 975 - 984
  • [45] Sensitive detection of hydroquinone using exfoliated graphene-Au/glassy carbon modified electrode
    Pogacean, Florina
    Coros, Maria
    Magerusan, Lidia
    Rosu, Marcela-Corina
    Socaci, Crina
    Gergely, Stefan
    van Staden, Raluca-Ioana Stefan
    Moldovan, Marioara
    Sarosi, Codruta
    Pruneanu, Stela
    NANOTECHNOLOGY, 2018, 29 (09)
  • [46] Ferrocene/graphene modified glassy carbon electrode for Chloromycetin detection
    Hu, Lin
    Zhou, Xiaoqin
    Li, Jinqing
    Bai, Tongtong
    Tang, Juan
    Zhou, Tao
    Cui, Qujin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (01): : 396 - 409
  • [47] Construction of Au nanoparticles on choline chloride modified glassy carbon electrode for sensitive detection of nitrite
    Wang, Po
    Mai, Zhibin
    Dai, Zong
    Li, Yongxin
    Zou, Xiaoyong
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (11): : 3242 - 3247
  • [48] Sensitive warfarin sensor based on cobalt oxide nanoparticles electrodeposited at multi-walled carbon nanotubes modified glassy carbon electrode (CoxOyNPs/MWCNTs/GCE)
    Gholivand, Mohammad Bagher
    Solgi, Mohammad
    ELECTROCHIMICA ACTA, 2017, 246 : 689 - 698
  • [49] A sensitive sensor based on molecularly imprinted polypyrrole on reduced graphene oxide modified glassy carbon electrode for nevirapine analysis
    Hassan Pour, Bayazid
    Haghnazari, Nahid
    Keshavarzi, Fatemeh
    Ahmadi, Elahe
    Zarif, Bahareh Rahimian
    ANALYTICAL METHODS, 2021, 13 (40) : 4767 - 4777
  • [50] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390