Polymer scaffold layers of screen-printed electrodes for homogeneous deposition of silver nanoparticles: application to the amperometric detection of hydrogen peroxide

被引:13
|
作者
Goud, K. . Yugender [1 ,2 ,3 ]
Kumar, V. Sunil [1 ,2 ]
Hayat, Akhtar [4 ]
Catanante, Gaelle [1 ]
Gobi, K. Vengatajalabathy [2 ]
Marty, Jean Louis [1 ]
机构
[1] Univ Perpignan, BAE Lab, Via Domitia,52 Ave Paul Alduy, F-66860 Perpignan, France
[2] Natl Inst Technol, Dept Chem, Warangal 506004, Telangana, India
[3] Univ Calif San Diego, Dept NanoEngn, La Jolla, CA 92093 USA
[4] COMSATS Univ Islamabad, IRCBM, Lahore Campus, Islamabad 54000, Pakistan
关键词
Electrodeposition; PEG; Hexamethylenediamine; H2O2; Electrochemical sensor; Scaffold layer; Amperometry; Voltammetry; Toothpaste analysis; ELECTROCHEMICAL SENSORS; GRAPHENE; NANOSTRUCTURES; H2O2;
D O I
10.1007/s00604-019-3963-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for electrochemical oxidation of polymers on the surface of screen-printed electrodes (SPCE). These act as scaffold layers for homogeneous deposition of silver nanoparticles (AgNPs). Hexamethylenediamine (HMDA) and poly(ethylene glycol) were immobilized on the SPCE surface via electrochemical oxidation. AgNPs were then electrodeposited on the scaffolds on the SPCE. This type of different carbon chain containing materials like PEG and HMDA act as big tunnels for electron mobility and are useful for the homogenous deposition of AgNPs on the SPCE surface without agglomeration. The resulting sensor was applied to the determination of hydrogen peroxide (H2O2) as a model analyte. It is found to display favorable catalytic and conductive properties towards the reduction of H2O2. Cyclic voltammetry and amperometry revealed that the modified electrode performs better than other modified SPCEs. Best operated at a potential of around -0.61 V (vs Ag|AgCl), the amperometric response is linear in the 10-180 mu M H2O2 concentration range and the detection limit is 1.5 mu M. The sensor is stable and reproducible. The resultant sensor was appplied to toothpaste analysis, and good recovery values were gained.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Polymer scaffold layers of screen-printed electrodes for homogeneous deposition of silver nanoparticles: application to the amperometric detection of hydrogen peroxide
    K . Yugender Goud
    V. Sunil Kumar
    Akhtar Hayat
    Gaelle Catanante
    K. Vengatajalabathy Gobi
    Jean Louis Marty
    Microchimica Acta, 2019, 186
  • [2] Screen-Printed Soft-Nitrided Carbon Electrodes for Detection of Hydrogen Peroxide
    Ogbu, Chidiebere I.
    Feng, Xu
    Dada, Samson N.
    Bishop, Gregory W.
    SENSORS, 2019, 19 (17)
  • [3] Modulating the Assembly of Sputtered Silver Nanoparticles on Screen-Printed Carbon Electrodes for Hydrogen Peroxide Electroreduction: Effect of the Surface Coverage
    Niu, Xiangheng
    Shi, Libo
    Pan, Jianming
    Qiu, Fengxian
    Yan, Yongsheng
    Zhao, Hongli
    Lan, Minbo
    ELECTROCHIMICA ACTA, 2016, 199 : 187 - 193
  • [4] Application of an ELISA-type amperometric assay to the detection of Vibrio species with screen-printed electrodes
    Laczka, Olivier
    Labbate, Maurizio
    Doblin, Martina
    ANALYTICAL METHODS, 2014, 6 (07) : 2020 - 2023
  • [5] Amperometric determination of sulfite using screen-printed electrodes modified with metallic nanoparticles
    Begoña Molinero-Abad
    María Asunción Alonso-Lomillo
    Olga Domínguez-Renedo
    María Julia Arcos-Martínez
    Microchimica Acta, 2013, 180 : 1351 - 1355
  • [6] Amperometric determination of sulfite using screen-printed electrodes modified with metallic nanoparticles
    Molinero-Abad, Begona
    Asuncion Alonso-Lomillo, Maria
    Dominguez-Renedo, Olga
    Julia Arcos-Martinez, Maria
    MICROCHIMICA ACTA, 2013, 180 (13-14) : 1351 - 1355
  • [7] Fabrication and characterisation of novel screen-printed tubular microband electrodes, and their application to the measurement of hydrogen peroxide
    Rawson, F. J.
    Purcell, W. M.
    Xu, J.
    Cowell, D. C.
    Fielden, P. R.
    Biddle, N.
    Hart, J. P.
    ELECTROCHIMICA ACTA, 2007, 52 (25) : 7248 - 7253
  • [8] Improving the detection of hydrogen peroxide of screen-printed carbon paste electrodes by modifying with nonionic surfactants
    Yuan, Chiun-Jye
    Wang, Yen-Chi
    Reiko, Ohara
    ANALYTICA CHIMICA ACTA, 2009, 653 (01) : 71 - 76
  • [9] An amperometric bacterial biosensor based on gold screen-printed electrodes for the detection of benzene
    Lanyon, Yvonne H.
    Tothill, Ibtisam E.
    Mascini, Marco
    ANALYTICAL LETTERS, 2006, 39 (08) : 1669 - 1681
  • [10] Indirect Amperometric Detection of Glucose in Simulated Urine Using Screen-Printed Electrodes
    Huseinov, Artur
    Alvarez, Noe T.
    JOURNAL OF CHEMICAL EDUCATION, 2024, 101 (03) : 1139 - 1145