Improving the detection of hydrogen peroxide of screen-printed carbon paste electrodes by modifying with nonionic surfactants

被引:6
|
作者
Yuan, Chiun-Jye [1 ]
Wang, Yen-Chi [1 ]
Reiko, Ohara [2 ]
机构
[1] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu 300, Taiwan
[2] Ind Technol Res Inst, Energy & Resources Labs, Hsinchu 310, Taiwan
关键词
Nomonic surfactant; Screen-printed carbon paste electrode; Triton X-100; Tween-20 Electrocatalytic activity; ELECTROCHEMICAL-BEHAVIOR; BIOSENSORS;
D O I
10.1016/j.aca.2009.08.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nonionic surfactants, such as Triton X-100 and Tween-20, were shown in this study to improve the electroatalytic activity of screen-printed carbon paste electrodes (SPCE) The electrochemical response of SPCE to hydrogen peroxide increased 8-10-fold with the modification of nonionic surfactants. In addition, the glucose biosensors fabricated from nonionic surfactant-modified SPCE exhibited 64-8 6-fold higher response to glucose than that fabricated from unmodified SPCE A concentration effect is proposed for nonionic surfactant to bring neutral reactants to the surface of electrode. Moreover, nonionic surfactant-modified SPCE exhibits a capability of repetitive usage and good reproducibility (R S D < 5%) in the measurement of H2O2 Interestingly, the nonionic surfactant-modified SPCE exhibited an opposite effect to ascorbic acid, a common electroactive agent, which causes interference during clinical diagnosis The differential responses of nonionic surfactant-modified SPCE to H2O2 and ascorbic acid Suggest its potential in the development of biosensors for clinical diagnosis (C) 2009 Elsevier B.V. All rights reserved
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [1] Disposal screen-printed carbon paste electrodes for the potentiometric titration of surfactants
    Khaled, Elmorsy
    Mohamed, Gehad G.
    Awad, T.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) : 74 - 80
  • [2] Screen-Printed Soft-Nitrided Carbon Electrodes for Detection of Hydrogen Peroxide
    Ogbu, Chidiebere I.
    Feng, Xu
    Dada, Samson N.
    Bishop, Gregory W.
    SENSORS, 2019, 19 (17)
  • [3] A hydrogen peroxide sensor prepared by electropolymerization of pyrrole based on screen-printed carbon paste electrodes
    Li, Guang
    Wang, You
    Xu, Hui
    SENSORS, 2007, 7 (03): : 239 - 250
  • [4] Highly activated screen-printed carbon electrodes by electrochemical treatment with hydrogen peroxide
    Gonzalez-Sanchez, I.
    Gomez-Monedero, B.
    Agrisuelas, J.
    Iniesta, J.
    Valero, E.
    ELECTROCHEMISTRY COMMUNICATIONS, 2018, 91 : 36 - 40
  • [5] Modification of Screen-printed Carbon Electrodes with Gold Particles to Enhance Luminol Electrochemiluminescence for Hydrogen Peroxide Detection
    Syukur, Junjunan M.
    Rahmawati, Isnaini
    Sanjaya, Afiten R.
    Ridwan, Muhammad
    Fiorani, Andrea
    Einaga, Yasuaki
    Ivandini, Tribidasari A.
    SENSORS AND MATERIALS, 2023, 35 (05) : 1785 - 1799
  • [6] Screen-Printed Carbon Electrodes for the Detection of Boldenone
    Kaur, Rameeta
    Khan, Aamir Amanat Ali
    Dennis, John Ojur
    Abdullah, Mohd Azmuddin
    PROCESS AND ADVANCED MATERIALS ENGINEERING, 2014, 625 : 809 - +
  • [7] Electrochemical characterization of screen-printed and conventional carbon paste electrodes
    Fanjul-Bolado, Pablo
    Hernandez-Santos, David
    Lamas-Ardisana, Pedro Jos
    Martin-Pernia, Alberto
    Costa-Garcia, Agustin
    ELECTROCHIMICA ACTA, 2008, 53 (10) : 3635 - 3642
  • [8] Flow injection analysis of hydrogen peroxide on copper-plated screen-printed carbon electrodes
    Zen, JM
    Chung, HH
    Kumar, AS
    ANALYST, 2000, 125 (09) : 1633 - 1637
  • [9] Electrochemical characterisation of novel screen-printed carbon paste electrodes for voltammetric measurements
    Sys, Milan
    Khaled, Elmorsy
    Metelka, Radovan
    Vytras, Karel
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2017, 82 (7-8) : 865 - 877
  • [10] Stripping Voltammetric Measurement of Trace Metal Ions at Screen-printed Carbon and Carbon Paste Electrodes
    Somerset, Vernon
    Iwuoha, Emmanuel
    Hernandez, Lucas
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 1279 - +