Real-world experience with a novel biodegradable polymer sirolimus-eluting stent: twelve-month results of the BIOFLOW-III registry

被引:37
|
作者
Waltenberger, Johannes [1 ]
Brachmann, Johannes [2 ]
van der Heyden, Jan [3 ]
Richardt, Gert [4 ]
Froebert, Ole [5 ]
Seige, Markus [6 ]
Erglis, Andrejs [7 ]
Dewilde, Willem [8 ]
Winkens, Mark [8 ]
Hegeler-Molkewehrum, Christian [9 ]
Klein, Norbert [10 ]
Hoffmannn, Stefan [11 ]
机构
[1] Univ Klinikum Munster, Dept Cardiovasc Med, Albert Schweitzer Campus 1,Gebeiude A1, D-48149 Munster, Germany
[2] Klinikum Coburg, Med Klin 2, Coburg, Germany
[3] St Antonius Hosp, Dept Cardiol, Nieuwegein, Netherlands
[4] Herzzentrum Segeberger Kliniken GmbH, Dept Cardiol & Angiol, Bad Segeberg, Germany
[5] Univ Sjukhuset Orebro, Dept Cardiol, Orebro, Sweden
[6] Krankenhaus Martha Maria gGmbH, Med Klin 1, Halle, Germany
[7] Univ Latvia, Paul Stradins Clin Univ Hosp, Latvian Ctr Cardiol, Riga, Latvia
[8] Twee Steden Hosp Tilburg, Dept Cardiol, Tilburg, Netherlands
[9] Kardiol Angiol Praxis Hegeler, Bremen, Germany
[10] Univ Leipzig, Dept Cardiol, D-04109 Leipzig, Germany
[11] Vivantes Klinikum Friedrichshain, Dept Internal Med & Cardiol, Berlin, Germany
关键词
biodegradable polymer; bioresorbable stent; coronary artery disease; drug-eluting stent; PLLA; sirolimus; NON-INFERIORITY TRIAL;
D O I
10.4244/EIJY15M03_08
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: We aimed to assess the safety and performance of a novel sirolimus-eluting stent with biodegradable polymer under real-world conditions. Methods and results: This prospective, multicentre, observational, all-corners registry enrolled 1,356 patients. The primary endpoint was target lesion failure at 12 months: it occurred in 5.1% (95% CI: 4.0-6.4) of patients in the overall population and in 7.7% (95% CI: 5.5-10.9), 5.8% (95% CI: 4.2-8.1), 1.8% (95% CI: 0.2-11.8) and 7.2% (95% CI: 5.1-10.0) of patients with diabetes mellitus, small vessels, chronic total occlusion and acute myocardial infarction, respectively. Conclusions: This novel stent platform demonstrated good clinical outcomes in an all-corners population, even in predefined high-risk groups. ClinialTrials.gov identifier: NCT01553526
引用
收藏
页码:1106 / 1110
页数:5
相关论文
共 50 条
  • [21] Real-World Clinical Performance of a Novolimus-Eluting Stent Versus a Sirolimus-Eluting Stent
    Chang, Chun-Chin
    Sung, Wei-Ting
    Lu, Ya-Wen
    Chuang, Ming-Ju
    Lee, Yin-Hao
    Tsai, Yi-Lin
    Chou, Ruey-Hsing
    Huang, Shao-Sung
    Huang, Po-Hsun
    CLINICAL CARDIOLOGY, 2024, 47 (07)
  • [22] Real world use of ultra-thin sirolimus-eluting stent with biodegradable polymers. 9-month results from the FLEX-registry.
    Lemos, Pedro A.
    Chandwani, Prakash
    Saxena, Sudheer
    Ramachandran, Padma Kumar
    Marchini, Julio F.
    Galon, Micheli Z.
    Abhyankar, Atul
    Verma, Puneet
    Sandhu, Manjinder Singh
    Parikh, Nikhil
    Bhupali, Ashok N.
    Jain, Sharad
    Prajapati, Jayesh
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B197 - B198
  • [23] Comparison of the Ultrathin Strut, Biodegradable Polymer Sirolimus-eluting Stent With a Durable Polymer Everolimus-eluting Stent in a Chinese Population: The Randomized BIOFLOW VI Trial
    Li, Chongjian
    Yang, Yuejin
    Han, Yaling
    Song, Dan
    Xu, Jing
    Guan, Changdong
    Gao, Runlin
    Garcia-Garcia, Hector M.
    Waksman, Ron
    Xu, Bo
    CLINICAL THERAPEUTICS, 2020, 42 (04) : 649 - +
  • [24] Subacute stent thrombosis after successful placement of sirolimus-eluting coronary stents: Real-world experience
    Jeremias, A
    Bridges, J
    Bigelow, B
    Sylvia, B
    Ho, KK
    Pinto, DS
    Cohen, DJ
    Cutlip, DE
    Carrozza, JP
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 98A - 98A
  • [25] Effectiveness of a novel biodegradable polymer, sirolimus-eluting stent platform in percutaneous coronary intervention
    Dominici, Marcello
    Arrivi, Alessio
    Bazzucchi, Marco
    De Paolis, Marcella
    Milici, Caterina
    Bock, Carlo
    Placanica, Attilio
    Lazzari, Ludovico
    Diletti, Roberto
    Boschetti, Enrico
    MINERVA CARDIOANGIOLOGICA, 2016, 64 (01): : 1 - 8
  • [26] Real-world registry of the durable Angiolite fluoroacrylate polymer-based sirolimus-eluting stent: the EPIC02 RANGO study
    Perez de Prado, Armando
    Ocaranza-Sanchez, Raymundo
    Lozano Ruiz-Poveda, Fernando
    Moreu Burgos, Jose
    Alvarez Ramos, Raquel
    Rodrigues, Alberto
    Fernandez Gonzalez, Luis
    Aguar, Pablo
    Garcia del Blanco, Bruno
    Pinar, Eduardo
    Peral, Vicente
    Sainz Laso, Fermin
    Ramon Rumoroso, Jose
    Torres, Alfonso
    Sabate, Manel
    Trillo Nouche, Ramiro
    REC-INTERVENTIONAL CARDIOLOGY, 2021, 3 (04): : 258 - 266
  • [27] The Firehawk Stent: A Review of a Novel Abluminal Groove-Filled Biodegradable Polymer Sirolimus-Eluting Stent
    Saito, Yuichi
    Grubman, Daniel
    Cristea, Ecaterina
    Lansky, Alexandra
    CARDIOLOGY IN REVIEW, 2020, 28 (04) : 208 - 212
  • [28] Predictors of Clinical Outcomes After Implantation of Novel Sirolimus-Eluting Stent in Real-World Patient Population
    Dani, Sameer
    Desai, Devang
    Pandya, Rashmit
    Parekh, Pritesh
    Vasavada, Apurva
    Bhalani, Nirav
    Sharma, Arvind
    Sheth, Chirag
    Shah, Dinesh
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B281 - B281
  • [29] Twelve-Month Clinical Outcomes After Implantation of Long Ultrathin Sirolimus-Eluting Stents With Biodegradable Polymers in Atherosclerotic Coronary Lesions
    Ajmera, Prakash
    Babu, Pothineni Ramesh
    Chawla, Kamal Kumar
    Mantravadi, Sai Sudhakar
    Jariwala, Pankaj
    Vijan, Vinod
    Vijan, Vikrant
    Potdar, Anil
    Inamdar, M. K.
    Pathak, Abhijit
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B115 - B115
  • [30] Real-World Experience with Bigfoot Unity-A Twelve-Month Retrospective Analysis
    Tillman, John
    Olson, Byron P.
    Malone, James K.
    DIABETES, 2024, 73