Measurement of the characteristics of the ventilation pipe of the filtration system for the steam-gas medium of a nuclear power plant

被引:0
|
作者
Kalyakin, SG [1 ]
Tsyganok, AA [1 ]
Taranov, GS [1 ]
Grigor'ev, MM [1 ]
机构
[1] State Sci Ctr Russian Federat, AI Leipunksii Phys & Power Engn Inst, Moscow, Russia
关键词
Filtration; Power Plant; Heat Exchanger; Temperature Field; Nuclear Power Plant;
D O I
10.1023/B:ATEN.0000047686.31470.41
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The dependence of the heat power of a pipe (air-air heat exchanger) on the flow rate and tire temperature of the heating air is investigated experimentally. The temperature fields along the height of tire pipe are measured. In the experimental velocity range 1.2-9.5 m/sec and heating-air temperature range 120-280degreesC. the heat power depends strongly on the temperature and negligibly on the flow rate of the hearing air. Increasing the cold-air flow rate increases the thermal power in direct proportion.
引用
收藏
页码:583 / 586
页数:4
相关论文
共 50 条
  • [41] Special features of steam–gas flow through a crack in the protective envelope of a nuclear power plant
    S. G. Kalyakin
    A. A. Tsyganok
    G. S. Taranov
    M. M. Grigor’ev
    Atomic Energy, 2004, 97 (5) : 744 - 749
  • [42] Analysis of Dynamic Characteristics and Parameter Influence of High Energy Pipe Whip in a Nuclear Power Plant
    Zhao W.
    Luo X.
    Wang P.
    Jiang J.
    Shang Y.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2019, 47 (06): : 80 - 86
  • [43] A study on steam cycle optimization for integrating energy storage system to nuclear power plant
    Lee, Ju Yeon
    Lee, Jeong Ik
    ANNALS OF NUCLEAR ENERGY, 2021, 160
  • [44] Performance Assessment for the Water Level Control System in Steam Generator of the Nuclear Power Plant
    Zhang Zhi
    Hu Lisheng
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 5842 - 5847
  • [45] Performance assessment for the water level control system in steam generator of the nuclear power plant
    Zhang, Zhi
    Hu, Li-Sheng
    ANNALS OF NUCLEAR ENERGY, 2012, 45 : 94 - 105
  • [46] Characteristics Testing of the ECT Bobbin Probe for Steam Generator Tube Inspection of Nuclear Power Plant
    Nam, Minwoo
    Lee, Heejong
    Cho, Chanhee
    Yoo, Hyunjoo
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2010, 30 (04) : 386 - 395
  • [47] Study on Nuclear Island Modeling and Parameter Measurement of Medium Pressure PWR Nuclear Power Plant in Power Grid Stability Calculation
    Yu Da-Hai
    Yu Xiu-Yue
    Nian Ming
    Su Yi
    Tao Xiang-Yu
    Xu Zhen-Hua
    Huo Cheng-Xiang
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 4720 - 4728
  • [48] Real-time displacement monitoring system for high temperature steam pipe of fossil power plant
    Hyun, JS
    Song, GW
    Cho, SY
    Lee, YS
    ADVANCES IN FRACTURE AND STRENGTH, PTS 1- 4, 2005, 297-300 : 2164 - 2168
  • [49] Development of on-line displacement monitoring system for high temperature steam pipe of fossil power plant
    Wook, Song Gee
    Seob, Hyun Jung
    Young, Cho Sun
    VTT Symposium (Valtion Teknillinen Tutkimuskeskus), 2004, (234): : 635 - 646
  • [50] Development of on-line displacement monitoring system for high temperature steam pipe of fossil power plant
    Wook, SG
    Seob, HJ
    Young, CS
    BALTICA VI: LIFE MANAGEMENT AND MAINTENANCE FOR POWER PLANTS, VOL 1 AND 2, 2004, 233-234 : 635 - 646