Bacterial Contamination of Ultrasound Probes at a Tertiary Referral University Medical Center

被引:11
|
作者
Chu, Kelly [1 ]
Obaid, Haron [1 ]
Babyn, Paul [1 ]
Blondeau, Joseph [2 ,3 ,4 ,5 ]
机构
[1] Univ Saskatchewan, Royal Univ Hosp, Dept Med Imaging, Saskatoon, SK S7N 0W8, Canada
[2] Royal Univ Hosp, Dept Clin Microbiol, Saskatoon, SK S7N 0W8, Canada
[3] Univ Saskatchewan, Dept Microbiol & Immunol, Saskatoon, SK S7N 0W8, Canada
[4] Univ Saskatchewan, Dept Pathol, Saskatoon, SK S7N 0W8, Canada
[5] Univ Saskatchewan, Dept Ophthalmol, Saskatoon, SK S7N 0W8, Canada
关键词
bacteria; contamination; infection; probe; ultrasound; GEL; OUTBREAK; REDUCE; RISK;
D O I
10.2214/AJR.13.12407
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the adequacy of our institution's ultrasound probe-disinfecting protocols, determine compliance with the guidelines, and then implement changes if needed. MATERIALS AND METHODS. We first assessed the prevalence of bacterial contamination (and thus the potential for bacterial transmission) by swabbing all ultrasound probes (n = 31) in the radiology department and culturing the samples. Next, in conditions simulating the typical work environment, we determined the efficacy of our probe-disinfecting protocols by seeding probes with 10(4)-10(9) CFU/mL of methicillin-resistant Staphylococcus aureus (MRSA), disinfecting the seeded probes with 0.5% accelerated hydrogen peroxide, and then swabbing the disinfected probes to assess for bacterial growth. RESULTS. Seven of 31 (22.6%) probes were positive for bacterial growth-none of which were endocavity probes (0/4). Four of 14 visibly soiled probes (28.6%) showed bacterial growth, and four of seven probes positive for bacteria (57.1%) were visibly soiled. No MRSA grew after seeding probes with MRSA and then disinfecting with 0.5% accelerated hydrogen peroxide. Sonography guidelines and general disinfecting guidelines were reviewed. CONCLUSION. Our protocols for disinfecting nonendocavity and endocavity probes are compliant with sonography guidelines and general disinfecting guidelines. Although limited by a small sample size, our study showed that our protocol for disinfecting endocavity probes seems adequate. With a 25.9% bacterial contamination rate for nonendocavity probes, the adequacy of our protocol for disinfecting nonendocavity probes is more debatable; however, this bacterial contamination rate is at the lower end of the values reported in the literature. With the use of an effective disinfectant, education of sonographers, and implemented changes, we hope to decrease bacterial contamination rates and thus decrease the potential for bacterial transmission.
引用
收藏
页码:928 / 932
页数:5
相关论文
共 50 条
  • [31] Study of bacterial contamination of keyboard and mouse in a medical school computer center
    Mehdinejad, Manijeh
    Khosravi, Azar Dokht
    Afzali, Marjan
    Mahmoudabadi, Ali Zarei
    HEALTHMED, 2012, 6 (03): : 889 - 892
  • [32] Experience with DaTscan at a tertiary referral center
    Sadasivan, Suja
    Friedman, Joseph H.
    PARKINSONISM & RELATED DISORDERS, 2015, 21 (01) : 42 - 45
  • [33] Esophageal dilation at a tertiary referral center
    Joyce, AM
    Ginsberg, G
    Katzka, DA
    Long, WB
    Metz, DC
    Kochman, ML
    GASTROINTESTINAL ENDOSCOPY, 2005, 61 (05) : AB133 - AB133
  • [34] Bacterial contamination on the white coats of medical laboratory students at a tertiary care hospital
    Nayak, Kusumakshi
    Shetty, Seema
    Poojary, Akshaya
    Prabhu, Thejaswini
    REVIEWS AND RESEARCH IN MEDICAL MICROBIOLOGY, 2023, 34 (04): : 201 - 206
  • [35] 2 METHODS OF IMPROVING REFERRAL INFORMATION - COMPARATIVE STUDY IN A UNIVERSITY MEDICAL CENTER
    BATES, B
    TORKELSON, LO
    MEDICAL CARE, 1967, 5 (06) : 418 - 422
  • [36] Retrospective analysis of PSMA PET/CT thyroid incidental uptake in adults: incidence, diagnosis, and treatment/outcome in a tertiary cancer referral center and University Medical Center
    Marceline W. Piek
    Lisa H. de Vries
    Maarten L. Donswijk
    Bart de Keizer
    Jan Paul de Boer
    Lutske Lodewijk
    Rachel S. van Leeuwaarde
    Menno R. Vriens
    Koen J. Hartemink
    Iris M. C. van der Ploeg
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 2392 - 2400
  • [37] Retrospective analysis of PSMA PET/CT thyroid incidental uptake in adults: incidence, diagnosis, and treatment/outcome in a tertiary cancer referral center and University Medical Center
    Piek, Marceline W.
    de Vries, Lisa H.
    Donswijk, Maarten L.
    de Keizer, Bart
    de Boer, Jan Paul
    Lodewijk, Lutske
    van Leeuwaarde, Rachel S.
    Vriens, Menno R.
    Hartemink, Koen J.
    van der Ploeg, Iris M. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (07) : 2392 - 2400
  • [38] The epidemiology of severe sepsis at a German tertiary care university medical center
    Audebert, F
    Straub, RH
    Salzberger, B
    Schölmerich, J
    Glück, T
    SHOCK, 2004, 21 : 106 - 106
  • [39] Health resource utilization and multidisciplinary impact of endoscopic ultrasonography in a tertiary referral medical center
    Sodikoff, Jamie B.
    Garud, Sagar S.
    Keilin, Steven A.
    Bharmal, Sheila J.
    Lewis, Melinda M.
    Cai, Qiang
    Willingham, Field F.
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2013, 6 (03): : 199 - 203
  • [40] Detailed Fetal Anatomic Ultrasound Examination: Effect of the 2014 Consensus Report on a Tertiary Referral Center
    Fratto, Victoria M.
    Chang, Aileen
    Anton, Tracy
    Sun, Heather Y.
    Lamale-Smith, Leah M.
    Pretorius, Dolores H.
    ULTRASOUND QUARTERLY, 2019, 35 (01) : 21 - 29