Comprehensive overview of the Point-by-Point model of prompt emission in fission

被引:27
|
作者
Tudora, A. [1 ]
Hambsch, F. -J. [2 ]
机构
[1] Univ Bucharest, Fac Phys, 405 Atomistilor Str,POB MG 11, Bucharest RO-77125, Romania
[2] European Commiss, Joint Res Ctr, Directorate Nucl Safety & Secur G, Unit G2, Retieseweg 111, B-2440 Geel, Belgium
来源
EUROPEAN PHYSICAL JOURNAL A | 2017年 / 53卷 / 08期
关键词
NEUTRON-INDUCED FISSION; NUCLEAR-DATA; ENERGY; MULTIPLICITY; FRAGMENTS; CF-252; U-235; SPECTRUM; PU-239; YIELDS;
D O I
10.1140/epja/i2017-12347-9
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The investigation of prompt emission in fission is very important in understanding the fission process and to improve the quality of evaluated nuclear data required for new applications. In the last decade remarkable efforts were done for both the development of prompt emission models and the experimental investigation of the properties of fission fragments and the prompt neutrons and.-ray emission. The accurate experimental data concerning the prompt neutron multiplicity as a function of fragment mass and total kinetic energy for Cf-252(SF) and U-235(n, f) recently measured at JRC-Geel (as well as other various prompt emission data) allow a consistent and very detailed validation of the Point-by-Point (PbP) deterministic model of prompt emission. The PbP model results describe very well a large variety of experimental data starting from the multi-parametric matrices of prompt neutron multiplicity nu(A, TKE) and gamma-ray energy E-gamma(A, TKE) which validate the model itself, passing through different average prompt emission quantities as a function of A (e.g.,nu(A), E-gamma(A), <epsilon > (A) etc.), as a function of TKE (e.g., nu(TKE), E-gamma(TKE)) up to the prompt neutron distribution P(nu) and the total average prompt neutron spectrum. The PbP model does not use free or adjustable parameters. To calculate the multi-parametric matrices it needs only data included in the reference input parameter library RIPL of IAEA. To provide average prompt emission quantities as a function of A, of TKE and total average quantities the multi-parametric matrices are averaged over reliable experimental fragment distributions. The PbP results are also in agreement with the results of the Monte Carlo prompt emission codes FIFRELIN, CGMF and FREYA. The good description of a large variety of experimental data proves the capability of the PbP model to be used in nuclear data evaluations and its reliability to predict prompt emission data for fissioning nuclei and incident energies for which the experimental information is completely missing. The PbP treatment can also provide input parameters of the improved Los Alamos model with non-equal residual temperature distributions recently reported by Madland and Kahler, especially for fissioning nuclei without any experimental information concerning the prompt emission.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] THE MINISTERS REPLY EXAMINED A POINT-BY-POINT COMMENTARY
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1948, 1 (4541): : 109 - 112
  • [22] CLEVELAND TERMINAL TOWER - POINT-BY-POINT ILLUMINATION
    不详
    LIGHTING DESIGN & APPLICATION, 1983, 13 (03): : 20 - 23
  • [23] Prompt fission neutron data calculation using experimental fission fragment charge distributions in the frame of the Point by Point treatment
    Tudora, Anabella
    ANNALS OF NUCLEAR ENERGY, 2010, 37 (01) : 43 - 51
  • [24] Rapid Point-by-Point Pulmonary Vein Isolation
    Michaud, Gregory F.
    Narayan, Sanjiv M.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (07) : 787 - 788
  • [25] Design of an IRFPA Point-by-Point Bias Calibration
    He, Wei
    Lv, Jian
    Zhou, Yun
    Du, Yiying
    Yu, Caideng
    Xie, Guangzhong
    Yuan, Kai
    6TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTOELECTRONIC MATERIALS AND DEVICES FOR SENSING, IMAGING, AND SOLAR ENERGY, 2012, 8419
  • [26] Combined Circular Multielectrode Catheter and Point-by-Point Ablation. is Superior to Point-by-Point Ablation Alone in Eliminating Atrial Fibrillation
    Richter, Bernhard
    Gwechenberger, Marianne
    Kriegisch, Michael
    Albinni, Sulaima
    Marx, Manfred
    Goessinger, Heinz D.
    CIRCULATION, 2012, 126 (21)
  • [27] A POINT-BY-POINT REBUKE OF REVISION EFFORTS ON COBOL STANDARDS
    DUBNOW, AE
    DATA MANAGEMENT, 1981, 19 (12): : A32 - L32
  • [28] How to improve the efficacy of point-by-point radiofrequency ablation
    Bertaglia, Emanuele
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (03) : 451 - 452
  • [29] Improved point-by-point algorithm for generating nonparametric curves
    Wang, Pengjie
    Song, Haiyu
    Li, Wei
    Journal of Computational Information Systems, 2007, 3 (02): : 781 - 787
  • [30] DETERMINATION OF TRUE POINT-BY-POINT HEART WALL STIFFNESS
    RIVERS, DB
    RANSON, WF
    CAULFIELD, JB
    BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1981, 9 (04): : 299 - 299