A comparison of Monte Carlo fission models for safeguards neutron coincidence counters

被引:3
|
作者
Weinmann-Smith, R. K. [1 ,2 ]
Swinhoe, M. T. [2 ]
Trahan, A. [2 ]
Andrews, M. T. [2 ]
Menlove, H. O. [2 ]
Enqvist, A. [1 ]
机构
[1] Los Alamos Natl Lab, POB 1663,MS E540, Los Alamos, NM 87545 USA
[2] Univ Florida, Gainesville, FL 32611 USA
关键词
FREYA; CGMF; MCNP; Safeguards; Neutron coincidence and multiplicity counting; SPECTRA; PERFORMANCE; POLIMI;
D O I
10.1016/j.nima.2018.06.055
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monte Carlo simulation is a powerful tool used to model neutron coincidence detectors for international safeguards. The simulation has typically sampled properties such as the fission neutron multiplicity, energy, and direction, from independent probability density functions. However, multiplicity counters detect event-based neutron correlations and thus more accurate fission event modeling is needed. To respond to this need, the Fission Reaction Event Yield Algorithm (FREYA) and the Cascading Gamma-ray Multiplicity with Fission (CGMF) models were added in the newest version of MCNP, MCNP6.2. The models simulate individual fission events conserving momentum, energy, and angular momentum such that correlated particles are emitted. The effects of the new models on simulations of safeguards neutron coincidence counters were studied and compared to standard MCNP simulations. The MCNPX-PoliMi model was also included in the comparison. The properties of fission neutrons from safeguards relevant isotopes were compared to literature references. Then a hypothetical simplified detector was modeled to isolate the effects of specific differences between models. Experimental measurements from previous work were modeled and agreements were compared. Finally, the probabilities of correlated events occurring in the experimental measurements were calculated with the different models. For example, the probability was calculated of detecting neutrons from both induced fission in uranium and spontaneous fission of Cf-252 in the same fission chain.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 50 条
  • [31] Monte Carlo simulation of fast neutron-induced fission of 237Np
    Liu, Chang-Qi
    Wei, Zheng
    Han, Chao
    Huang, Chang
    Huang, Zhi-Wu
    Ma, Zhan-Wen
    Zhang, Shuang-Jiao
    Peng, Shao-Hua
    Li, Wei-Min
    Bai, Xiao-Hou
    Wang, Jun-Run
    Lu, Xiao-Long
    Zhang, Yu
    Xu, Da-Peng
    Su, Xiao-Dong
    Yao, Ze-En
    CHINESE PHYSICS C, 2019, 43 (06)
  • [32] Spatial distribution of thorium fission rate in a fast spallation and fission neutron field: An experimental and Monte Carlo study
    Borger, J. J.
    Hashemi-Nezhad, S. R.
    Alexiev, D.
    Brandt, R.
    Westmeier, W.
    Thomauske, B.
    Adam, J.
    Kadykov, M.
    Tiutiunnikov, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 664 (01): : 103 - 110
  • [33] Determination of natural uranium fission rate in fast spallation and fission neutron field: An experimental and Monte Carlo study
    Hashemi-Nezhad, S. R.
    Zhuk, Igor
    Kievets, A.
    Krivopustov, M. I.
    Sosnin, A. N.
    Westmeier, W.
    Brandt, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (03): : 517 - 529
  • [34] Reliability of Monte Carlo simulations in modeling neutron yields from a shielded fission source
    McArthur, Matthew S.
    Rees, Lawrence B.
    Czirr, J. Bart
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 827 : 46 - 51
  • [35] Analytic and Monte Carlo random walk assessments of neutron fission chains and the probability of extinction
    Durkee, Joe W., Jr.
    PROGRESS IN NUCLEAR ENERGY, 2021, 142
  • [36] Monte Carlo simulation of fast neutron-induced fission of 237Np
    刘昌奇
    韦峥
    韩超
    黄畅
    黄智武
    马占文
    张双佼
    彭少华
    李卫敏
    白晓厚
    王俊润
    卢小龙
    张宇
    徐大鹏
    苏小东
    姚泽恩
    Chinese Physics C, 2019, 43 (06) : 18 - 24
  • [37] Uncertainty Quantification of Prompt Fission Neutron Spectra Using the Unified Monte Carlo Method
    Rising, M. E.
    Talou, P.
    Prinja, A. K.
    NUCLEAR DATA SHEETS, 2014, 118 : 360 - 363
  • [38] Unified Monte Carlo: Evaluation, Uncertainty Quantification and Propagation of the Prompt Fission Neutron Spectrum
    Rising, Michael E.
    Talou, Patrick
    Prinja, Anil K.
    White, Morgan C.
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [39] Monte Carlo investigation and optimization of coincidence prompt gamma-ray neutron activation analysis
    Wang, Jiaxin
    Calderon, Adan
    Peeples, Cody R.
    Ai, Xianyun
    Gardner, Robin P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 572 - 577
  • [40] Neutron Coincidence Measurements and Monte Carlo Modelling of Waste Drums Containing Reference Nuclear Material
    Borella, A.
    Rossa, R.
    Boden, S.
    Bruggeman, C.
    Rogiers, B.
    Smets, S.
    Valcke, E.
    ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253