Shock tube/time-of-flight mass spectrometer for high temperature kinetic studies

被引:41
|
作者
Tranter, Robert S.
Giri, Binod R.
Kiefer, John H.
机构
[1] Argonne Natl Lab, Div Chem, Argonne, IL 60439 USA
[2] Univ Illinois, Dept Chem Engn, Chicago, IL 60607 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2007年 / 78卷 / 03期
关键词
D O I
10.1063/1.2437150
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A shock tube (ST) with online, time-of-flight mass spectrometric (TOF-MS) detection has been constructed for the study of elementary reactions at high temperature. The ST and TOF-MS are coupled by a differentially pumped molecular beam sampling interface, which ensures that the samples entering the TOF-MS are not contaminated by gases drawn from the cold end wall thermal boundary layer in the ST. Additionally, the interface allows a large range of postshock pressures to be used in the shock tube while maintaining high vacuum in the TOF-MS. The apparatus and the details of the sampling system are described along with an analysis in which cooling of the sampled gases and minimization of thermal boundary layer effects are discussed. The accuracy of kinetic measurements made with the apparatus has been tested by investigating the thermal unimolecular dissociation of cyclohexene to ethylene and 1,3-butadiene, a well characterized reaction for which considerable literature data that are in good agreement exist. The experiments were performed at nominal reflected shock wave pressures of 600 and 1300 Torr, and temperatures ranging from 1260 to 1430 K. The rate coefficients obtained are compared with the earlier shock tube studies and are found to be in very good agreement. As expected no significant difference is observed in the rate constant between pressures of 600 and 1300 Torr. (c) 2007 American Institute of Physics.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] A time-of-flight mass spectrometer to resolve isobars
    Ishida, Y
    Wada, M
    Matsuo, Y
    Tanihata, I
    Casares, A
    Wollnik, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 219 : 468 - 472
  • [32] A NEW TIME-OF-FLIGHT MASS-SPECTROMETER
    SU, CS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 220 (2-3): : 431 - 432
  • [33] NEW CAPABILITY FOR TIME-OF-FLIGHT MASS SPECTROMETER
    不详
    ANALYTICAL CHEMISTRY, 1965, 37 (8P1) : A95 - &
  • [34] SHOCK-TUBE COUPLED TO THE TIME-OF-FLIGHT MASS-SPECTROMETER VIA A MOLECULAR-BEAM SAMPLING SYSTEM
    KRIZANCIC, I
    HALUK, M
    CHO, SH
    TRASS, O
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1979, 50 (07): : 909 - 915
  • [36] Computer optimization for high-resolution time-of-flight mass spectrometer
    Even, U
    Dick, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (12): : 4415 - 4420
  • [37] Coupling of a High-Resolution Ambient Pressure Drift Tube Ion Mobility Spectrometer to a Commercial Time-of-flight Mass Spectrometer
    Allers, Maria
    Timoumi, Laila
    Kirk, Ansgar T.
    Schlottmann, Florian
    Zimmermann, Stefan
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (11) : 2208 - 2217
  • [38] A diaphragmless shock tube for high temperature kinetic studies
    Tranter, Robert S.
    Giri, Binod R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (09):
  • [39] Adaptation and operation of a quadrupole/time-of-flight tandem mass spectrometer for high mass ion/ion reaction studies
    Bhanot, Jay S.
    Fabijanczuk, Kimberly C.
    Abdillahi, Abdirahman M.
    Chao, Hsi-Chun
    Pizzala, Nicolas J.
    Londry, Frank A.
    Dziekonski, Eric T.
    Hager, James W.
    McLuckey, Scott A.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 478
  • [40] A COMPACT TIME-OF-FLIGHT SPECTROMETER FOR ELECTROFISSION STUDIES
    HEIL, RD
    DREXLER, J
    HUBER, K
    KNEISSL, U
    MANK, G
    RIES, H
    STROHER, H
    WEBER, T
    WILKE, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 239 (03): : 545 - 550