Evaluation of a Dengue IgG Indirect Enzyme-Linked Immunosorbent Assay and a Japanese Encephalitis IgG Indirect Enzyme-Linked Immunosorbent Assay for Diagnosis of Secondary Dengue Virus Infection

被引:39
|
作者
Inoue, Shingo [1 ,8 ]
Alonzo, Maria T. G. [2 ]
Kurosawa, Yae [3 ]
Mapua, Cynthia A. [4 ]
Reyes, Joyce D. [4 ]
Dimaano, Efren M. [5 ]
Alera, Maria Theresa P. [6 ]
Saito, Mariko [7 ]
Oishi, Kazunori [2 ]
Hasebe, Futoshi [1 ,8 ]
Matias, Ronald R. [4 ]
Natividad, Filipinas F. [4 ]
Morita, Kouichi [1 ,8 ]
机构
[1] Nagasaki Univ, Dept Virol, Inst Trop Med, Nagasaki 8528523, Japan
[2] Osaka Univ, Microbial Dis Res Inst, Int Res Ctr Infect Dis, Dept Special Pathogens, Osaka, Japan
[3] Pentax Co Ltd, Tokyo, Japan
[4] St Lukes Med Ctr, Res & Biotechnol Div, Quezon City, Philippines
[5] San Lazaro Hosp, Blood Borne Dis Ward, Manila, Philippines
[6] Vicente Sotto Mem Med Ctr, Philippines AFRIMS Virol Res Unit, Cebu, Philippines
[7] Tohoku Univ, Grad Sch Med, Dept Virol, Sendai, Miyagi 980, Japan
[8] MEXT, 21st Century COE Program, Global COE Program, Tokyo, Japan
关键词
Dengue; HI test; IgG indirect ELISA; Japanese encephalitis; Secondary dengue infection; RAPID IMMUNOCHROMATOGRAPHIC TEST; IMMUNOGLOBULIN-M IGM; HEMAGGLUTINATION-INHIBITION; CROSS-REACTIVITY; ANTIBODIES; ELISA; FEVER; DIFFERENTIATION;
D O I
10.1089/vbz.2008.0153
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
To establish a new method for the diagnosis of dengue secondary infection, 187 serum samples from the patients with dengue secondary infection, 40 serum samples from the patients with dengue primary infection, and 44 serum samples from the healthy volunteers were tested using the dengue IgG indirect enzyme-linked immunosorbent assay (DEN IgG ELISA). The results of the test were compared with those from the dengue hemagglutination inhibition (DEN HI) test, which has been recommended as the gold standard by the World Health Organization (WHO, 1997). Japanese encephalitis IgG indirect ELISA (JE IgG ELISA) was also performed to measure anti-flavivirus IgG, which cross-reacts with the Japanese encephalitis virus, to test the possibility of an alternative to DEN IgG ELISA. The results of DEN IgG and JE IgG ELISAs were highly correlated with those of the DEN HI test. In the DEN IgG ELISA, a titer of 1:29,000 was the cut-off value for the diagnosis of dengue secondary infection (91.5% accuracy [95% confidence interval, CI], 90.9% sensitivity [95%CI], and 92.9% specificity [95%CI]). A titer of 1:52,000 was the cut-off value for dengue secondary infection using JE IgG ELISA (95.6% accuracy [95%CI], 98.9% sensitivity [95%CI], and 88.1% specificity [95%CI]). In conclusion, this study confirmed that the results of both DEN IgG and JE IgG ELISAs were highly correlated with the results of DEN HI test. Thus, these ELISAs are simple, rapid, sensitive, and quantitative tests that can be used in the determination of dengue secondary infection.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [21] Evaluation of a New Commercially Available Immunoglobulin M Capture Enzyme-Linked Immunosorbent Assay for Diagnosis of Dengue Virus Infection
    Namekar, Madhuri
    Ellis, Esther M.
    O'Connell, Maile
    Elm, Joe
    Gurary, Alexandra
    Park, Sarah Y.
    Imrie, Allison
    Nerurkar, Vivek R.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (09) : 3102 - 3106
  • [22] Early detection of Fasciola gigantica infection in buffaloes by enzyme-linked immunosorbent assay and dot enzyme-linked immunosorbent assay
    Niranjan Kumar
    S. Ghosh
    S. C. Gupta
    Parasitology Research, 2008, 103 : 141 - 150
  • [23] Early detection of Fasciola gigantica infection in buffaloes by enzyme-linked immunosorbent assay and dot enzyme-linked immunosorbent assay
    Kumar, Niranjan
    Ghosh, S.
    Gupta, S. C.
    PARASITOLOGY RESEARCH, 2008, 103 (01) : 141 - 150
  • [24] Diagnostic sensitivity of enzyme-linked immunosorbent assay for IgG in hydatid disease
    Sandhu, Pushpinder Singh
    Attri, A. K.
    Chandra, M.
    INDIAN JOURNAL OF SURGERY, 2009, 71 (04) : 202 - 205
  • [25] Diagnostic sensitivity of enzyme-linked immunosorbent assay for IgG in hydatid disease
    Pushpinder Singh Sandhu
    A. K. Attri
    M. Chandra
    Indian Journal of Surgery, 2009, 71 : 202 - 205
  • [26] Validation of the indirect TaSP enzyme-linked immunosorbent assay for diagnosis of Theileria annulata infection in cattle
    Dia Eldin A. Salih
    Jabbar S. Ahmed
    Mohammed A. Bakheit
    Elzein B. Ali
    Abdelrahim M. El. Hussein
    Shawgi M. Hassan
    Omer E. Shariff
    M. Fadl
    Frans Jongejan
    Parasitology Research, 2005, 97 : 302 - 308
  • [27] Enzyme-linked immunosorbent assay for detection of IgG against penicillins in children
    Zhang, L
    Wang, YM
    Shen, G
    Chen, BY
    ACTA PHARMACOLOGICA SINICA, 1996, 17 (03): : 274 - 277
  • [28] Validation of the indirect TaSP enzyme-linked immunosorbent assay for diagnosis of Theileria annulata infection in cattle
    Salih, DEA
    Ahmed, JS
    Bakheit, MA
    Ali, EB
    El Hussein, AM
    Hassan, SM
    Shariff, OE
    Fadl, M
    Jongejan, F
    PARASITOLOGY RESEARCH, 2005, 97 (04) : 302 - 308
  • [29] Diagnosis of Acute Dengue Virus Infection Using Enzyme-Linked Immunosorbent Assay and Real-Time PCR
    Iqbal, Gohar
    Javed, Hasnain
    Raza, Faiz Ahmed
    Gohar, Umar Farooq
    Fatima, Warda
    Khurshid, Mohsin
    CANADIAN JOURNAL OF INFECTIOUS DISEASES & MEDICAL MICROBIOLOGY, 2023, 2023
  • [30] Evaluation of musk by enzyme-linked immunosorbent assay
    Ahn, KS
    Hahn, BS
    Lee, JP
    Chang, SY
    Lee, HK
    Jeong, CS
    Kim, YS
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2002, 25 (04) : 418 - 421