The Arcus Soft X-ray Grating Spectrometer Explorer

被引:8
|
作者
Smith, Randall [1 ]
机构
[1] Ctr Astrophys Harvard & Smithsonian, 60 Garden St, Cambridge, MA 02138 USA
来源
SPACE TELESCOPES AND INSTRUMENTATION 2020: ULTRAVIOLET TO GAMMA RAY | 2021年 / 11444卷
关键词
X-ray gratings; X-rays: Spectroscopy; Missing baryons; Explorer missions;
D O I
10.1117/12.2576047
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Arcus will provide high-resolution soft X-ray spectroscopy in the 12-50 angstrom bandpass with sensitivity orders of magnitude higher than any previous astronomical observatory. The three top science goals for Arcus are to (1) measure the effects of structure formation imprinted upon the hot baryons that are predicted to lie in extended halos around galaxies, groups, and clusters, (2) trace the propagation of outflowing mass, energy, and momentum from the vicinity of the black hole to extragalactic scales as a measure of their feedback and (3) explore how stars form and evolve. Arcus uses 12m focal length grazing-incidence silicon pore X-ray optics (SPO) identical to those developed for the Athena mission, including focal length and radius of curvature. The focused X-rays from these optics are diffracted by high-efficiency Critical-Angle Transmission (CAT) gratings, and the results are imaged with flight-proven CCD detectors and electronics.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Critical-angle transmission grating technology development for high resolving power soft x-ray spectrometers on Arcus and Lynx
    Heilmann, Ralf K.
    Bruccoleri, Alexander R.
    Song, Jungki
    Kolodziejczak, Jeffery
    Gaskin, Jessica A.
    O'Dell, Stephen L.
    Cheimetz, Peter
    Hertz, Edward
    Smith, Randall K.
    Burwitz, Vadim
    Hartner, Gisela
    La Caria, Marlis-Madeleine
    Schattenburg, Mark L.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY VIII, 2017, 10399
  • [42] Pinhole transmission grating spectrometer of X-ray picosecond frame
    Jinxiu Cheng
    Tianshu Wen
    Cunbang Yang
    Zhijian Zheng
    Jiabin Chen
    Shuping Liu
    Shaojun Fu
    Yiling Hong
    Science in China Series A: Mathematics, 1998, 41 : 546 - 550
  • [43] Pinhole transmission grating spectrometer of X-ray picosecond frame
    成金秀
    温天舒
    杨存榜
    郑志坚
    陈家斌
    刘淑萍
    付绍军
    洪义麟
    Science China Mathematics, 1998, (05) : 546 - 550
  • [44] Pinhole transmission grating spectrometer of X-ray picosecond frame
    成金秀
    温天舒
    杨存榜
    郑志坚
    陈家斌
    刘淑萍
    付绍军
    洪义麟
    ScienceinChina,SerA., 1998, Ser.A.1998 (05) : 546 - 550
  • [45] Pinhole transmission grating spectrometer of X-ray picosecond frame
    Cheng, JX
    Wen, TS
    Yang, CB
    Zheng, ZJ
    Chen, JB
    Liu, SP
    Fu, SJ
    Hong, YL
    SCIENCE IN CHINA SERIES A-MATHEMATICS PHYSICS ASTRONOMY, 1998, 41 (05): : 546 - 550
  • [46] High resolution solar soft X-ray spectrometer
    张飞
    王焕玉
    彭文溪
    梁晓华
    张春雷
    曹学蕾
    姜维春
    张家宇
    崔兴柱
    中国物理C, 2012, 36 (02) : 146 - 150
  • [47] Laboratory vacuum spectrometer for the soft x-ray region
    Yuryev, Yu. N.
    Lee, Hwack-Joo
    Kim, Ju-Hwang
    Cho, Yang-Koo
    Lee, Min-Kyu
    Pogrebitsky, K. Ju.
    X-RAY SPECTROMETRY, 2008, 37 (05) : 476 - 481
  • [48] Spectrometer for polarized soft X-ray Raman scattering
    Synchrotron Radiation Laboratory, Institute for Solid State Physics, University of Tokyo, Tanashi, Tokyo 188, Japan
    不详
    J. Synchrotron Radiat., 3 (1013-1015):
  • [49] A DOUBLE-CRYSTAL SOFT X-RAY SPECTROMETER
    SUONINEN, E
    KARRAS, M
    LEVOSKA, J
    ACTA POLYTECHNICA SCANDINAVICA-PHYSICS INCLUDING NUCLEONICS SERIES, 1970, (71): : 1 - &
  • [50] Calibration of a High Resolution Soft X-Ray Spectrometer
    Dunn, J.
    Beiersdorfer, P.
    Brown, G. V.
    Magee, E. W.
    X-RAY LASERS 2008, PROCEEDINGS, 2009, 130 : 461 - 467