Current evidence for the use of C-MAC videolaryngoscope in adult airway management: a review of the literature

被引:27
|
作者
Xue, Fu-Shan [1 ,2 ]
Li, Hui-Xian
Liu, Ya-Yang
Yang, Gui-Zhen
机构
[1] Chinese Acad Med Sci, Plast Surg Hosp, Dept Anesthesiol, 33 Ba Da Chu Rd, Beijing 100144, Peoples R China
[2] Peking Union Med Coll, 33 Ba Da Chu Rd, Beijing 100144, Peoples R China
关键词
videolaryngoscopy; direct laryngoscopy; airway management; tracheal intubation; patient safety; RANDOMIZED CONTROLLED-TRIAL; CERVICAL-SPINE IMMOBILIZATION; C-MAC(R) VIDEO LARYNGOSCOPE; PREDICTED DIFFICULT AIRWAY; RAPID-SEQUENCE INTUBATION; NATIONAL AUDIT PROJECT; INTENSIVE-CARE-UNIT; EMERGENCY-DEPARTMENT; TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE;
D O I
10.2147/TCRM.S136221
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The C-MAC videolaryngoscope is the first Macintosh-typed videolaryngoscope. Since the advent of its original version video Macintosh system in 1999, this device has been modified several times. A unique feature of C-MAC device is its ability to provide the 2 options of direct and video laryngoscopy with the same device. The available evidence shows that in patients with normal airways, C-MAC videolaryngoscope compared with direct laryngoscopy can provide comparable or better laryngeal views and exerts less force on maxillary incisors, but does not offer conclusive benefits with regard to intubation time, intubation success, number of intubation attempts, the use of adjuncts, and hemodynamic responses to intubation. In patients with predicted or known difficult airways, C-MAC videolaryngoscope can achieve a better laryngeal view, a higher intubation success rate and a shorter intubation time than direct laryngoscopy. Furthermore, the option to perform direct and video laryngoscopy with the same device makes C-MAC videolaryngoscope exceptionally useful for emergency intubation. In addition, the C-MAC videolaryngoscope is a very good tool for tracheal intubation teaching. However, tracheal intubation with C-MAC videolaryngoscope may occasionally fail and introduction of C-MAC videolaryngoscope in clinical practice must be accompanied by formal training programs in normal and difficult airway managements.
引用
收藏
页码:831 / 841
页数:11
相关论文
共 50 条
  • [31] Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization
    Gupta, Nidhi
    Rath, Girija Prasad
    Prabhakar, Hemanshu
    JOURNAL OF ANESTHESIA, 2013, 27 (05) : 663 - 670
  • [32] C-MAC videolaryngoscope improves the laryngoscopic view in Mallampati class 2 and 3 patients
    Ninan, Jestin Elias
    Ranjan, R., V
    Ramachandran, T. R.
    George, Sagiev Koshy
    ANAESTHESIA PAIN & INTENSIVE CARE, 2016, 20 (03) : 261 - 265
  • [33] Is the C-MAC videolaryngoscope plus Frova introducer suitable for intubating the trachea of every patient?
    Onal, O.
    Sari, M.
    Aslanlar, E.
    ANAESTHESIA, 2018, 73 (08) : 1033 - 1034
  • [34] Comparison of ease of intubation in right and left lateral position using C-MAC videolaryngoscope
    Bhat, Ravi
    Sanickop, C. S.
    Dhorigoll, M. G.
    Umrani, Vijay
    Suresh, S. N.
    ANAESTHESIA PAIN & INTENSIVE CARE, 2013, 17 (02) : 162 - 165
  • [35] Hemodynamic responses to tracheal intubation with Bonfils compared to C-MAC videolaryngoscope: a randomized trial
    Youssef Ezhar
    Frederick D’Aragon
    Pablo Echave
    BMC Anesthesiology, 18
  • [36] Use of the C-MAC® adult D blade in paediatric patients with Nager syndrome
    Lean, L. L.
    King, C.
    ANAESTHESIA AND INTENSIVE CARE, 2016, 44 (05) : 647 - 648
  • [37] Hemodynamic responses to tracheal intubation with Bonfils compared to C-MAC videolaryngoscope: a randomized trial
    Ezhar, Youssef
    D'Aragon, Frederick
    Echave, Pablo
    BMC ANESTHESIOLOGY, 2018, 18
  • [38] Präklinische Atemwegssicherung bei TraumapatientenErfahrungen mit dem C-MAC®-VideolaryngoskopOut-of-hospital airway management in trauma patientsExperiences with the C-MAC® video laryngoscope
    B. Hossfeld
    A. Jongebloed
    L. Lampl
    M. Helm
    Der Unfallchirurg, 2016, 119 (6): : 501 - 507
  • [39] The C-MAC Videolaryngoscope: First Experiences with a New Device for Videolaryngoscopy-Guided Intubation
    Cavus, Erol
    Kieckhaefer, Joerg
    Doerges, Volker
    Moeller, Thora
    Thee, Carsten
    Wagner, Klaus
    ANESTHESIA AND ANALGESIA, 2010, 110 (02): : 473 - 477
  • [40] Comparison of C-MAC Videolaryngoscope, GlideScope Ranger and conventional laryngoscopy for tracheal intubation in patients with a predicted difficult airway - A randomized controlled trial
    Reifferscheid, F.
    Michelson, I.
    Doerges, V.
    Steinfath, M.
    Bein, B.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 263 - 264