Reusable potentiometric screen-printed sensor and label-free aptasensor with pseudo-reference electrode for determination of tryptophan in the presence of tyrosine

被引:48
|
作者
Majidi, Mir Reza [1 ]
Omidi, Yadollah [2 ]
Karami, Pari [1 ]
Johari-Ahar, Mohammad [2 ]
机构
[1] Univ Tabriz, Dept Analyt Chem, Fac Chem, Tabriz, Iran
[2] Tabriz Univ Med Sci, RCPN, Tabriz, Iran
关键词
Potentiometric stripping analysis; RNA aptamer; Multiwall carbon nanotube; Screen-printed electrode; PERFORMANCE LIQUID-CHROMATOGRAPHY; CARBON-PASTE ELECTRODE; SELECTIVE DETERMINATION; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; STRIPPING ANALYSIS; MODIFIED GCE; ACID; NANOPARTICLES; NANOTUBES;
D O I
10.1016/j.talanta.2015.12.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analysis of t-tryptophan (Trp) in biological samples has great importance for biomedical studies. Amino acid tyrosine (Tyr) that usually coexist with Trp in biological fluids can significantly interfere with reliable determination of Trp. In the current study, we demonstrate the development of two ultra-sensitive electrochemical sensor and label-free aptasensor for selective analysis of Trp in biological samples (i.e., cow's milk and human plasma, saliva and urine samples). In addition, without using AgCl/KCl, an Ag pseudo-reference screen printed electrode (Ag-PR-SPE) was exploited as a reference electrode. To prepare the engineered Trp sensor/aptasensor, a gold SPE was first modified with multiwall carbon nano tube (MWCNT-AuSPE) and then armed with Trp aptamer molecules (Apt-MWCNT-AuSPE). The prepared sensors were characterized using constant current-potentiometric stripping analysis (CC-PSA) and electrochemical impedance spectroscopy (EIS). The MWCNT-AuSPE and Apt-MWCNT-AuSPE were compared with respect to the linear detection range, limit of detection (LOD), accuracy, precision, repeatability. MWCNT-AuSPE and Apt-MWCNT-AuSPE demonstrate fast near-Nernstian response for PSA of Trp over the concentration ranging from 1.0 x 10(-9) to 2.0 x 10(-4) mol L-1 and 1.0 x 10(-11) to 1.0 x 10(-4) mol L-1 with detection limits of 3.6 x 10(-10) mol L-1 and 4.9 x 10(-12) mol L-1, respectively. Common interfering species present in the biological fluids (i.e., tyrosine, uric acid, ascorbic acid) showed no effects on the determination of Trp using CC-PSA. MWCNT-AuSPE and Apt-MWCNT-AuSPE represented well reproducibility and great precision with relative standard deviation (RSD) of 2.9% and 5.3% respectively. In comparison with the MWCNT-AuSPE, Apt-MWCNT-AuSPE provided higher sensitivity, selectivity and accuracy of Trp detection in real samples. Based on these findings, we propose the developed Apt-MWCNT-AuSPE as a simple detection method for analysis of Trp in biological samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 433
页数:9
相关论文
共 38 条
  • [31] Gold nano-flowers (Au NFs) modified screen-printed carbon electrode electrochemical biosensor for label-free and quantitative detection of glycated hemoglobin
    Wang, Xiao
    Su, Jing
    Zeng, Dongdong
    Liu, Gang
    Liu, Lizhuang
    Xu, Yi
    Wang, Chenguang
    Liu, Xinxin
    Wang, Lu
    Mi, Xianqiang
    TALANTA, 2019, 201 : 119 - 125
  • [32] A sensitive electrochemical immunosensor based on poly(2-aminobenzylamine) film modified screen-printed carbon electrode for label-free detection of human immunoglobulin G
    Putnin, Thitirat
    Jumpathong, Watthanachai
    Laocharoensuk, Rawiwan
    Jakmunee, Jaroon
    Ounnunkad, Kontad
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2018, 46 (05) : 1042 - 1051
  • [33] Electroanalytical Application of Screen-printed Carbon Electrode Modified with Conductive Graphene Oxide-Poly(acrylic acid) Film for Label-free Detection of Human Immunoglobulin G
    Norfun, Poachanee
    Jumpathong, Watthanachai
    Kungwan, Nawee
    Jakmunee, Jaroon
    Ounnunkad, Kontad
    CHEMISTRY LETTERS, 2016, 45 (12) : 1444 - 1446
  • [34] A nucleic acid dye-enhanced electrochemical biosensor for the label-free detection of Hg2+ based on a gold nanoparticle-modified disposable screen-printed electrode
    Liu, Wei
    Wang, Yunqi
    Sheng, Fangfang
    Wan, Bing
    Tang, Gangxu
    Xu, Shuxia
    ANALYTICAL METHODS, 2022, 14 (35) : 3451 - 3457
  • [35] A disposable aptasensing device for label-free detection of fumonisin B1 by integrating PDMS film-based micro-cell and screen-printed carbon electrode
    Ren, Chanchan
    Li, Huaming
    Lu, Xiaoting
    Qian, Jing
    Zhu, Mingyue
    Chen, Wei
    Liu, Qian
    Hao, Nan
    Li, Henan
    Wang, Kun
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 : 192 - 199
  • [36] Point-of-Care Detection of Carcinoembryonic Antigen (CEA) Using a Smartphone-Based, Label-Free Electrochemical Immunosensor with Multilayer CuONPs/CNTs/GO on a Disposable Screen-Printed Electrode
    Khonyoung, Supada
    Mangkronkaew, Praphatsorn
    Klayprasert, Puttaporn
    Puangpila, Chanida
    Palanisami, Muthukumaran
    Arivazhagan, Mani
    Jakmunee, Jaroon
    Biosensors, 2024, 14 (12):
  • [37] A highly sensitive and selective electrochemical sensor for determination of Cr(VI) in the presence of Cr(III) using modified multi-walled carbon nanotubes/quercetin screen-printed electrode
    Sadeghi, Susan
    Garmroodi, Aziz
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (08): : 4972 - 4977
  • [38] A Redox Cu(II)-Graphene Oxide Modified Screen Printed Carbon Electrode as a Cost-Effective and Versatile Sensing Platform for Electrochemical Label-Free Immunosensor and Non-enzymatic Glucose Sensor
    Phetsang, Sopit
    Khwannimit, Duangruedee
    Rattanakit, Parawee
    Chanlek, Narong
    Kidkhunthod, Pinit
    Mungkornasawakul, Pitchaya
    Jakmunee, Jaroon
    Ounnunkad, Kontad
    FRONTIERS IN CHEMISTRY, 2021, 9