Contralaterally evoked transient otoacoustic emissions

被引:2
|
作者
Pratt, H [1 ]
Shi, YB [1 ]
Polyakov, A [1 ]
机构
[1] Technion Israel Inst Technol, Evoked Potentials Lab, IL-32000 Haifa, Israel
关键词
transient evoked otoacoustic emission; efferent system; contralateral; human; click;
D O I
10.1016/S0378-5955(97)00178-0
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Contralaterally evoked transient otoacoustic emissions (CETOAEs) were recorded from 10 normal-hearing young adults (20 ears) in response to monaural, 11/s, 65 dB pe SPL clicks to the ear contralateral to the microphone probe. A burst of CETOAEs was observed 12-22 ms (average peak at 18.5 ms) after the contralateral cl ck, and its mean level was -7.3 dB pc SPL, 4 dB above the averaged noise level. The frequency content of CETOAEs included a prominence around 1 kHz. In 40%, of the ears examined CETOAEs were 3 dB or more above noise level in both replications of records from the same ear. To explain these results CETOAEs are suggested to reflect mechanical events induced by the crossed efferent system in the cochlea that was contralateral to the: stimulated ear. The latency of the contralateral responses suggests that they may be related to the contralateral suppression effect observed with binaural stimulation. The latency of the response, coupled with the anatomical origin of the crossed efferent system at the superior olivary complex, suggest its involvement in the contralateral CETOAEs reported here. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [31] Transient Evoked and Distortion Product Otoacoustic Emissions in a Group of Neonates
    Silva, Giovanna Cesar
    Delecrode, Camila Ribas
    Kemp, Adriana Tahara
    Martins, Fabiana
    Vieira Cardoso, Ana Claudia
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2015, 19 (03) : 255 - 258
  • [32] Transient evoked otoacoustic emissions in superior canal dehiscence syndrome
    Elsaeid M. Thabet
    European Archives of Oto-Rhino-Laryngology, 2011, 268 : 137 - 141
  • [33] Characteristics of transient-evoked otoacoustic emissions (TEOEs) in neonates
    Aidan, D
    Lestang, P
    Avan, P
    Bonfils, P
    ACTA OTO-LARYNGOLOGICA, 1997, 117 (01) : 25 - 30
  • [34] High-resolution Analysis of Transient Evoked Otoacoustic Emissions
    McNamara, D. M.
    Goli, A.
    Ziarani, A. K.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1898 - 1902
  • [35] Transient evoked otoacoustic emissions in superior canal dehiscence syndrome
    Thabet, Elsaeid M.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2011, 268 (01) : 137 - 141
  • [36] Detection of transient evoked otoacoustic emissions by adaptive signal enhancement
    YE Wanxing YE Datian CAO Yu(Biomedical Engineering Institute
    ChineseJournalofAcoustics, 2003, (04) : 302 - 313
  • [37] Twin study of neonatal transient-evoked otoacoustic emissions
    Johansson, Marlin
    Olofsson, Ake
    Berninger, Erik
    HEARING RESEARCH, 2020, 398
  • [38] Transient evoked otoacoustic emissions in patients with middle ear disorders
    Zhao, F
    Wada, H
    Koike, T
    Ohyama, K
    Kawase, T
    Stephens, D
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2003, 42 (03) : 117 - 131
  • [39] Repeatability of Transient-Evoked Otoacoustic Emissions in Young Adults
    Kochanek, Krzysztof M.
    Sliwa, Lech K.
    Puchacz, Klaudia
    Pilka, Adam
    MEDICAL SCIENCE MONITOR, 2015, 21 : 36 - 43
  • [40] Reliability of measures of transient evoked otoacoustic emissions with contralateral suppression
    Stuart, Andrew
    Cobb, Kensi M.
    JOURNAL OF COMMUNICATION DISORDERS, 2015, 58 : 35 - 42