Generally applicable window settings of low-keV virtual monoenergetic reconstructions in dual-layer CT-angiography of the head and neck

被引:7
|
作者
Zopfs, David [1 ,2 ]
Lennartz, Simon [1 ,2 ,3 ]
Abdullayev, Nuran [1 ,2 ]
Lichtenstein, Thorsten [1 ,2 ]
Laukamp, Kai Roman [1 ,2 ]
Reimer, Robert Peter [1 ,2 ]
Kabbasch, Christoph [1 ,2 ]
Borggrefe, Jan [4 ]
Schlamann, Marc [1 ,2 ]
Neuhaus, Victor [1 ,2 ]
Hokamp, Nils Grosse [1 ,2 ]
机构
[1] Univ Cologne, Fac Med, Dept Diagnost & Intervent Radiol, Kerpener Str 65, Cologne, Germany
[2] Univ Cologne, Univ Hosp Cologne, Kerpener Str 65, Cologne, Germany
[3] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[4] Ruhr Univ Bochum, Johannes Wesling Univ Hosp, Dept Radiol Neuroradiol & Nucl Med, Bochum, Germany
关键词
Computed tomography (CT) angiography; angiography; tomography; X-ray computed; head; neck; ENERGY CT; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; OPTIMIZATION; PRINCIPLES; STANDARD; STROKE; ARTERY;
D O I
10.21037/qims-20-1140
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Increased vessel contrast in low-keV virtual monoenergetic images (VMI) in spectral detector CT angiography of the head and neck requires adaption of window settings. Aim of this study was to define generally applicable window settings of low-keV VMI. Methods: Two radiologists determined ideal subjective window settings for VMI40-70 keV in 54 patients. To obtain generally applicable window settings, center and width values were modeled against the attenuation of the internal carotid artery (HUICA). This modeling was performed with and without respect to keV. Subsequently, image quality of VMI40-70 keV was assessed using the model-based determined window settings. Results: With decreasing keV values, HUICA increased significantly in comparison to conventional images (CI) (P<0.05 for 40-60 keV). No significant differences between modelled and individually recorded window settings were found confirming validity of the obtained models (P values: 0.2-1.0). However, modelling with respect to keV was marginally less precise. Conclusions: Window settings of low-keV VMI can be semi-automatically determined in dependency of the ICA attenuation in spectral detector CTA of the head and neck. The reported models are a promising tool to leverage the improved image quality of these images in clinical routine.
引用
收藏
页码:3408 / 3417
页数:10
相关论文
共 29 条
  • [21] Dual-layer detector CT of the head: Initial experience in visualization of intracranial hemorrhage and hypodense brain lesions using virtual monoenergetic images
    Lennartz, Simon
    Laukamp, Kai Roman
    Neuhaus, Victor
    Hokamp, Nils Grosse
    Le Blanc, Markus
    Maus, Volker
    Kabbasch, Christoph
    Mpotsaris, Anastasios
    Maintz, David
    Borggrefe, Jan
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 177 - 183
  • [22] Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging
    Beeres, Martin
    Trommer, Jesko
    Frellesen, Claudia
    Nour-Eldin, Nour-Eldin A.
    Scholtz, Jan E.
    Herrmann, Eva
    Vogl, Thomas J.
    Wichmann, Julian L.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01): : 137 - 144
  • [23] Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging
    Martin Beeres
    Jesko Trommer
    Claudia Frellesen
    Nour-Eldin A. Nour-Eldin
    Jan E. Scholtz
    Eva Herrmann
    Thomas J. Vogl
    Julian L. Wichmann
    The International Journal of Cardiovascular Imaging, 2016, 32 : 137 - 144
  • [24] Transcatheter Aortic Valve Implantation (TAVI) Planning with Dual-Layer Spectral CT Using Virtual Monoenergetic Image (VMI) Reconstructions and 20 mL of Contrast Media
    Fontana, Federico
    Piacentino, Filippo
    Gnesutta, Aroa
    Macchi, Edoardo
    Coppola, Andrea
    Saccomanno, Angiola
    Gatta, Tonia
    Recaldini, Chiara
    Minenna, Manuela
    Tamborini, Claudio
    Dossi, Filippo
    Ascenti, Velio
    Barbera, Simone
    Cicero, Giuseppe
    Carcano, Giulio
    Ascenti, Giorgio
    Castiglioni, Battistina
    Venturini, Massimo
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [25] Initial Clinical Experience of Virtual Monoenergetic Imaging Improves Stent Visualization in Lower Extremity Run-Off CT Angiography by Dual-Layer Spectral Detector CT
    Zhang, Daming
    Xie, Yanting
    Wang, Yining
    Guo, Ning
    Wang, Yun
    Jin, Zhengyu
    Xue, Huadan
    ACADEMIC RADIOLOGY, 2020, 27 (06) : 825 - 832
  • [26] VIRTUAL MONOENERGETIC SETTINGS IN LATEST SPECTRAL CT WITH DUAL-LAYER DETECTOR DIFFERENTIATE CONTRAST DEFECT IN LEFT ATRIAL APPENDAGE FROM PECTINATE MUSCLES AND THROMBI IN ATRIAL FIBRILLATION PATIENTS
    Funabashi, Nobusada
    Akaza, Shin
    Shukuya, Atsushi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 203 - 203
  • [27] Virtual Monoenergetic Images From a Novel Dual-Layer Spectral Detector Computed Tomography Scanner in Portal Venous Phase: Adjusted Window Settings Depending on Assessment Focus Are Essential for Image Interpretation
    Hickethier, Tilman
    Iuga, Andra-Iza
    Lennartz, Simon
    Hauger, Myriam
    Byrtus, Jonathan
    Luetkens, Julian A.
    Haneder, Stefan
    Maintz, David
    Doerner, Jonas
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (03) : 350 - 356
  • [28] Poly-energetic and virtual mono-energetic images from a novel dual-layer spectral detector CT: optimization of window settings is crucial to improve subjective image quality in abdominal CT angiographies
    Jonas Doerner
    Julian A. Luetkens
    Andra-Iza Iuga
    Jonathan Byrtus
    Stefan Haneder
    David Maintz
    Tilman Hickethier
    Abdominal Radiology, 2018, 43 : 742 - 750
  • [29] Poly-energetic and virtual mono-energetic images from a novel dual-layer spectral detector CT: optimization of window settings is crucial to improve subjective image quality in abdominal CT angiographies
    Doerner, Jonas
    Luetkens, Julian A.
    Iuga, Andra-Iza
    Byrtus, Jonathan
    Haneder, Stefan
    Maintz, David
    Hickethier, Tilman
    ABDOMINAL RADIOLOGY, 2018, 43 (03) : 742 - 750