A Physiological Signal Processing System for Optimal Engagement and Attention Detection

被引:0
|
作者
Belle, Ashwin [1 ]
Hobson, Rosalyn [2 ]
Najarian, Kayvan [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Comp Sci, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Dept Elect Engn, Richmond, VA 23284 USA
来源
2011 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE WORKSHOPS | 2011年
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper proposes a computer aided system that aims to measure and interpret physiological signals so as to assess the attention/engagement level of a person during cognitive based activities. In this study, ECG (Electrocardiogram), HF (Heat Flux) and EEG (Electroencephalogram) signals were collected from 8 subjects. The subjects were made to watch a series of videos which demanded contrasting engagement levels. On the collected ECG data, Discrete Wavelet Transform (DWT) is applied to the raw signal and multiple features are extracted. Features from HF were also obtained. In EEG signals, different band components were first extracted upon which DWT is applied to extract numerous features. Finally machine learning techniques were employed to classify the extracted features into two categories of 'attention' and 'non-attention'. The results show success in distinguishing 'attention' vs. 'non-attention' cases by processing acquired physiological signals.
引用
收藏
页码:555 / 561
页数:7
相关论文
共 50 条
  • [21] Optimal Combined Signal Processing
    J Commun Technol Electron, 2 (187-196):
  • [22] OPTIMAL ARCING FAULT-DETECTION USING SIGNAL-PROCESSING TECHNIQUES
    LI, SP
    RUSSELL, BD
    ELECTRIC POWER SYSTEMS RESEARCH, 1991, 21 (02) : 121 - 128
  • [23] A Broiler Stress Detection System Based on Audio Signal Processing
    Jakovljevic, Niksa
    Maljkovic, Nina
    Miskovic, Dragisa
    Knezevic, Petar
    Delic, Vlado
    2019 27TH TELECOMMUNICATIONS FORUM (TELFOR 2019), 2019, : 313 - 316
  • [24] Signal Processing and Detection for Array Reader Magnetic Recording System
    Xia, Haitao, Sr.
    Lu, Lu
    Jeong, Seongwook
    Pan, Lu
    Xiao, Jun
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (11)
  • [25] Stress detection in computer users based on digital signal processing of noninvasive physiological variables
    Zhai, Jing
    Barreto, Armando
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1999 - +
  • [26] Detection of Stress Level and Phases by Advanced Physiological Signal Processing Based on Fuzzy Logic
    Zalabarria, Unai
    Irigoyen, Eloy
    Martinez, Raquel
    Salazar-Ramirez, Asier
    INTERNATIONAL JOINT CONFERENCE SOCO'16- CISIS'16-ICEUTE'16, 2017, 527 : 301 - 312
  • [27] Machine Learning-based Signal Processing Using Physiological Signals for Stress Detection
    Ghaderi, Adnan
    Frounchi, Javad
    Farnam, Alireza
    2015 22ND IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2015, : 93 - 98
  • [28] Evaluation of the Backup Signal-processing System of the KSTAR Quench Detection System
    Yonekawa, Hirofumi
    Kim, Jinsub
    Kim, Young-ok
    Kim, Kwang-pyo
    Chu, Yong
    FUSION ENGINEERING AND DESIGN, 2020, 159
  • [29] Optimal methods of regular signal processing
    Vishnyakov, A.N.
    Avtomatika i Telemekhanika, 1993, 11 (11): : 81 - 88
  • [30] Adaptive signal processing of physiological hand tremor
    Zhang, J
    Chu, F
    Mohammed, N
    2005 IEEE NETWORKING, SENSING AND CONTROL PROCEEDINGS, 2005, : 147 - 152