Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion

被引:11
|
作者
Chang, Jun-Dong [1 ]
Kim, In-Sung [1 ]
Prabhakar, Sharad [1 ]
Mansukhani, Sameer A. [1 ]
Lee, Sang-Soo [2 ]
Yoo, Je-Hyun [3 ]
机构
[1] Hallym Univ, Dept Orthopaed Surg, Dongtan Sacred Heart Hosp, 7 Keunjaebong Gil, Hwaseong Si 445907, Gyeonggi Do, South Korea
[2] Hallym Univ, Chuncheon Sacred Heart Hosp, Dept Orthopaed Surg, Coll Med, Chunchon, South Korea
[3] Hallym Univ, Coll Med, Sacred Heart Hosp, Dept Orthopaed Surg, Anyang, South Korea
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 05期
关键词
imageless navigation; combined anteversion; revision total hip arthroplasty; component position; computer-assisted orthopaedic surgery; ACETABULAR COMPONENT; DISLOCATION; PLACEMENT;
D O I
10.1016/j.arth.2016.12.030
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion. Methods: A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 x stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40 degrees +/- 10 degrees and combined anteversion of the cup and femoral stem of 37 degrees +/- 10 degrees based on Widmer's equation were regarded as the "safe zone." Results: The average anteversion of the revised femoral stems was 15.3 degrees +/- 2.9 degrees (range, 9.5 degrees-21.5 degrees), whereas that of the remained femoral stems was 17.4 degrees +/- 9.7 degrees (range, 4.2 degrees-29.8 degrees). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3 degrees +/- 3.1 degrees (range, 32.1 degrees- 48.2 degrees), 25.0 degrees +/- 2.9 degrees (range, 16.9 degrees-29.5 degrees), and 36.1 degrees +/- 3.4 degrees (range, 27.2 degrees-42.9 degrees), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery. Conclusion: Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1576 / 1580
页数:5
相关论文
共 50 条
  • [21] Combined anteversion technique reduced the dislocation in cementless total hip arthroplasty
    Yasuharu Nakashima
    Masanobu Hirata
    Mio Akiyama
    Takashi Itokawa
    Takuaki Yamamoto
    Goro Motomura
    Masanobu Ohishi
    Satoshi Hamai
    Yukihide Iwamoto
    International Orthopaedics, 2014, 38 : 27 - 32
  • [22] Imageless navigation versus traditional method in total hip arthroplasty: A meta-analysis
    Liu, Zhengye
    Gao, Yan
    Cai, Lin
    INTERNATIONAL JOURNAL OF SURGERY, 2015, 21 : 122 - 127
  • [23] Fluoroscopy Versus Imageless Optical Navigation in Direct Anterior Approach Total Hip Arthroplasty
    Manzo, Marc A.
    Lex, Johnathan R.
    Rodriguez-Elizalde, Sebastian Rahul
    Perlus, Ryan
    Cayen, Barry
    Chang, Justin S.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2024, 32 (06) : e284 - e292
  • [24] Combined anteversion technique in total hip arthroplasty for Crowe IV developmental dysplasia of the hip
    Zhu, Biao
    Su, Changzheng
    He, Yeteng
    Chai, Xingyu
    Li, Zhen
    Hou, Zhenyang
    Lou, Tengteng
    Yan, Xinfeng
    HIP INTERNATIONAL, 2017, 27 (06) : 589 - 594
  • [25] Clinical experience with computer navigation in revision total hip arthroplasty
    Franke, Jochen
    Zheng, Guoyan
    Wendl, Klaus
    Gruetzner, Paul A.
    von Recum, Jan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H12) : 919 - 926
  • [26] Evaluation of Component Positioning in Primary Total Hip Arthroplasty Using an Imageless Navigation Device Compared With Traditional Methods
    Najarian, Brian C.
    Kilgore, John E.
    Markel, David C.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 15 - 21
  • [27] Development of an imageless navigation system for total knee arthroplasty
    Su Yingying
    Wang Chengtao
    Qi Yuanshuai
    Yan Shiju
    Gu Lixu
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6060 - 6063
  • [28] Differences in range of motion with the same combined anteversion after total hip arthroplasty
    Takaaki Ohmori
    Tamon Kabata
    Yoshitomo Kajino
    Tadashi Taga
    Kazuhiro Hasegawa
    Daisuke Inoue
    Takashi Yamamoto
    Tomoharu Takagi
    Junya Yoshitani
    Takuro Ueno
    Hiroyuki Tsuchiya
    International Orthopaedics, 2018, 42 : 1021 - 1028
  • [29] Preoperative planning and postoperative evaluation of total hip arthroplasty that takes combined anteversion
    Imai H.
    Miyawaki J.
    Kamada T.
    Takeba J.
    Mashima N.
    Miura H.
    European Journal of Orthopaedic Surgery & Traumatology, 2016, 26 (5) : 493 - 500
  • [30] Combined Anteversion Technique for the Modified Hardinge Approach in Cementless Total Hip Arthroplasty
    Suksathien, Yingyong
    Tippimanchai, Thanut
    TECHNIQUES IN ORTHOPAEDICS, 2021, 36 (04) : 416 - 420