High resolution Varying Field Drift Tube Ion Mobility Spectrometer with diffusion autocorrection

被引:5
|
作者
Chen, Xi [1 ,2 ]
Gandhi, Viraj [1 ,2 ]
Coots, Joshua [1 ,2 ]
Fan, Yinghui [3 ]
Xu, Liang [4 ,5 ]
Fukushima, Nobuhiko [6 ]
Larriba-Andaluz, Carlos [1 ]
机构
[1] IUPUI, Dept Mech Engn, 723 W Michigan St, Indianapolis, IN 46202 USA
[2] Purdue Univ, W Lafayette, IN 47907 USA
[3] Shantou Univ, Coll Engn, Shantou 515063, Peoples R China
[4] Shanghai Jiao Tong Univ, Key Lab Laser Plasmas, Minist Educ, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Sch Phys & Astron, Shanghai 200240, Peoples R China
[6] Kanomax Japan Inc, Suita, Osaka 5650805, Japan
关键词
Drift tube; Ion mobility; Differential mobility analyzer; PM0.1; Mobility diameter; IMS-IMS; NM;
D O I
10.1016/j.jaerosci.2019.105485
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Drift tubes (DT) are prominent tools to classify small ions in the gas phase. This is in contrast with its limited use in the aerosol field at atmospheric pressures where the differential mobility analyzer (DMA) has been the tool of choice. While the DMA has been successful, it does not normally achieve the resolution of a common DT. On the other hand, the size range of the DT is limited as well as its sensitivity. Here we propose a variation of the DT where a varying linearly decreasing field is used instead of the constant field commonly used in DT. The Varying Field Drift Tube (VFDT) has the advantage that it allows for diffusion constriction in the axial direction and thus a larger package of ions can be allowed into the system increasing its sensitivity without hampering its resolution. The VFDT also generally outperforms the DT in resolution and this is demonstrated theoretically and empirically reaching resolutions of over 90 in our data although higher resolutions are expected. The diffusion constriction capabilities are also proven theoretically and experimentally by using a mixture of tetraalkylammonium salts while injecting broad packets of ions into the system. The transformation from the raw variable arrival time distribution to Collision Cross Section or mobility diameter is linear making the transformation as simple as with a DMA.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Compact and Sensitive Dual Drift Tube Ion Mobility Spectrometer with a New Dual Field Switching Ion Shutter for Simultaneous Detection of Both Ion Polarities
    Lippmann, Martin
    Kirk, Ansgar T.
    Hitzemann, Moritz
    Zimmermann, Stefan
    ANALYTICAL CHEMISTRY, 2020, 92 (17) : 11834 - 11841
  • [22] Mobility Analysis of 2 nm to 11 nm Aerosol Particles with an Aspirating Drift Tube Ion Mobility Spectrometer
    Oberreit, Derek R.
    McMurry, Peter H.
    Hogan, Christopher J., Jr.
    AEROSOL SCIENCE AND TECHNOLOGY, 2014, 48 (01) : 108 - 118
  • [23] Evaluation of drift gas selection in complex sample analyses using a high performance drift tube ion mobility-QTOF mass spectrometer
    Kurulugama, Ruwan. T.
    Darland, Ed
    Kuhlmann, Frank
    Stafford, George
    Fjeldsted, John
    ANALYST, 2015, 14 (20) : 6834 - 6844
  • [24] Ion Profiling in an Ambient Drift Tube-Ion Mobility Spectrometer Using a High Pixel Density Linear Array Detector IonCCD
    Davila, Stephen J.
    Hadjar, Omar
    Eiceman, Gary A.
    ANALYTICAL CHEMISTRY, 2013, 85 (14) : 6716 - 6722
  • [25] Conformational Ordering of Biomolecules in the Gas Phase: Nitrogen Collision Cross Sections Measured on a Prototype High Resolution Drift Tube Ion Mobility-Mass Spectrometer
    May, Jody C.
    Goodwin, Cody R.
    Lareau, Nichole M.
    Leaptrot, Katrina L.
    Morris, Caleb B.
    Kurulugama, Ruwan T.
    Mordehai, Alex
    Klein, Christian
    Barry, William
    Darland, Ed
    Overney, Gregor
    Imatani, Kenneth
    Stafford, George C.
    Fjeldsted, John C.
    McLean, John A.
    ANALYTICAL CHEMISTRY, 2014, 86 (04) : 2107 - 2116
  • [26] ION DISTRIBUTION PROFILES IN THE DRIFT REGION OF AN ION MOBILITY SPECTROMETER
    KARPAS, Z
    EICEMAN, GA
    EWING, RG
    ALGOM, A
    AVIDA, R
    FRIEDMAN, M
    MATMOR, A
    SHAHAL, O
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 127 : 95 - 104
  • [27] Determination of the transfer function of an atmospheric pressure drift tube ion mobility spectrometer for nanoparticle measurements
    Buckley, David T.
    Hogan, Christopher J., Jr.
    ANALYST, 2017, 142 (10) : 1800 - 1812
  • [28] DRIFT MOBILITY TUBE/MASS SPECTROMETER MEASUREMENTS OF ENERGY DEPENDENCE OF ION-MOLECULE REACTIONS
    HEIMERL, J
    JOHNSEN, R
    BIONDI, MA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (02): : 205 - &
  • [29] Planar drift tube for ion mobility spectrometry
    Eiceman, Gary A.
    Schmidt, Hartwig
    Rodriguez, Jaime E.
    White, Corey R.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2007, 35 (04) : 365 - 383
  • [30] Ion Mobility Spectrometer-Fragmenter-Ion Mobility Spectrometer Analogue of a Triple Quadrupole for High-Resolution Ion Analysis at Atmospheric Pressure
    Amo-Gonzalez, Mario
    Carnicero, Irene
    Perez, Sergio
    Delgado, Rafael
    Eiceman, Gary A.
    Fernandez de la Mora, Gonzalo
    de la Mora, Juan Fernandez
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6885 - 6892