Intra-operative spectroscopic assessment of surgical margins during breast conserving surgery

被引:64
|
作者
Shipp, Dustin W. [1 ]
Rakha, Emad A. [2 ]
Koloydenko, Alexey A. [3 ]
Macmillan, R. Douglas [4 ]
Ellis, Ian O. [2 ]
Notingher, Ioan [1 ]
机构
[1] Univ Nottingham, Sch Phys & Astron, Nottingham NG7 2RD, England
[2] Univ Nottingham, Sch Med, Div Oncol, Nottingham NG5 1PB, England
[3] Royal Holloway Univ London, Math Dept, Egham TW20 0EX, Surrey, England
[4] Nottingham Univ Hosp NHS Trust, Nottingham Breast Inst, Nottingham NG5 1PB, England
基金
英国工程与自然科学研究理事会;
关键词
Auto-fluorescence; Breast cancer; Raman spectroscopy; Intra-operative margin evaluation; RAMAN-SPECTROSCOPY; AMERICAN SOCIETY; DIAGNOSIS; CANCER; TISSUE; TUMOR; LUMPECTOMY; EXCISION;
D O I
10.1186/s13058-018-1002-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: In over 20% of breast conserving operations, postoperative pathological assessment of the excised tissue reveals positive margins, requiring additional surgery. Current techniques for intra-operative assessment of tumor margins are insufficient in accuracy or resolution to reliably detect small tumors. There is a distinct need for a fast technique to accurately identify tumors smaller than 1 mm(2) in large tissue surfaces within 30 min. Methods: Multi-modal spectral histopathology (MSH), a multimodal imaging technique combining tissue auto-fluorescence and Raman spectroscopy was used to detect microscopic residual tumor at the surface of the excised breast tissue. New algorithms were developed to optimally utilize auto-fluorescence images to guide Raman measurements and achieve the required detection accuracy over large tissue surfaces (up to 4x6.5 cm(2)). Algorithms were trained on 91 breast tissue samples from 65 patients. Results: Independent tests on 121 samples from 107 patients - including 51 fresh, whole excision specimens - detected breast carcinoma on the tissue surface with 95% sensitivity and 82% specificity. One surface of each uncut excision specimen was measured in 12-24 min. The combination of high spatial-resolution autofluorescence with specific diagnosis by Raman spectroscopy allows reliable detection even for invasive carcinoma or ductal carcinoma in situ smaller than 1 mm(2). Conclusions: This study provides evidence that this multimodal approach could provide an objective tool for intra-operative assessment of breast conserving surgery margins, reducing the risk for unnecessary second operations.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Intra-operative Ultrasound-guided Conserving Surgery for Breast Cancer: No More Time for Blind Surgery
    Ferrucci, Massimo
    Milardi, Francesco
    Mpungu, Fabrizio
    Cagol, Matteo
    Toffanin, Maria Cristina
    Saibene, Tania
    Michieletto, Silvia
    Del Bianco, Paola
    Grigoletto, Raffaello
    Marchet, Alberto
    ANNALS OF SURGICAL ONCOLOGY, 2023, 30 (SUPPL 2) : S445 - S446
  • [22] Intra-operative assessment of excised breast tumour margins using ClearEdge imaging device
    Dixon, J. M.
    Renshaw, L.
    Young, O.
    Kulkarni, D.
    Saleem, T.
    Sarfaty, M.
    Sreenivasan, R.
    Kusnick, C.
    Thomas, J.
    Williams, L. J.
    EJSO, 2016, 42 (12): : 1834 - 1840
  • [23] Breast conserving surgery with intra-operative radiotherapy: The right approach for the 21st century?
    Tobias, J. S.
    Keshtgar, M.
    Douek, M.
    Vaidya, J. S.
    Stacey, C.
    Metaxas, M.
    Sainsbury, R.
    Baum, M.
    Proceedings of the XIV World Congress on Breast Diseases, 2006, : 97 - 103
  • [24] Effectiveness of intraoperative histologic assessment of surgical margins for breast-conserving surgery
    Aomatsu, Naoki
    Tei, Seika
    Hiramatsu, Soichiro
    Wang, En
    Iwauchi, Takehiko
    Nishii, Takafumi
    Morimoto, Junya
    Kosaka, Kinshi
    Uchima, Yasutake
    Takeuchi, Kazuhiro
    ANNALS OF ONCOLOGY, 2015, 26 : 128 - 128
  • [25] Performance metrics of an optical spectral imaging system for intra-operative assessment of breast tumor margins
    Bydlon, Torre M.
    Kennedy, Stephanie A.
    Richards, Lisa M.
    Brown, J. Quincy
    Yu, Bing
    Junker, Marlee K.
    Gallagher, Jennifer
    Geradts, Joseph
    Wilke, Lee G.
    Ramanujam, Nimmi
    OPTICS EXPRESS, 2010, 18 (08): : 8058 - 8076
  • [26] Follow up after intra-operative assessment of resection margins in oral cavity carcinoma surgery
    Smits, R.
    Van Lanschot, F.
    Schut, T. Bakker
    Hardillo, J.
    Mast, H.
    Ten Hove, I.
    Wolvius, E.
    Puppels, G.
    de Jong, R. Baatenburg
    Koljenovic, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 49 - 49
  • [27] Intra-operative assessment of sentinel lymph nodes for breast cancer surgery: An update
    Barkur, Surekha
    Notingher, Ioan
    Rakha, Emad
    SURGICAL ONCOLOGY-OXFORD, 2022, 40
  • [28] An intra-operative THz probe for use during the surgical removal of breast tumors
    Ashworth, Philip C.
    O'Kelly, Padraig
    Purushotham, Anand D.
    Pinder, Sarah E.
    Kontos, Michalis
    Pepper, Michael
    Wallace, Vincent P.
    2008 33RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES, VOLS 1 AND 2, 2008, : 767 - +
  • [29] Breast-conserving surgery with intra-operative radiotherapy: The right approach for the 21st century?
    Tobias, JS
    Vaidya, JS
    Keshtgar, M
    Douek, M
    Metaxas, M
    Stacey, C
    Sainsbury, R
    D'Souza, D
    Baum, M
    CLINICAL ONCOLOGY, 2006, 18 (03) : 220 - 228
  • [30] Full-dose intra-operative radiotherapy with electrons (ELIOT) during breast-conserving surgery: experience with 1246 cases
    Veronesi, U.
    Orecchia, R.
    Luini, A.
    Galimberti, V.
    Gatti, G.
    Intra, M.
    Veronesi, P.
    Leonardi, M. C.
    Ciocca, M.
    Lazzari, R.
    Caldarella, P.
    Rotmensz, N.
    Sangalli, C.
    Silva, L. S.
    Sances, D.
    ECANCERMEDICALSCIENCE, 2008, 2