Design of a low-cost instrument for pulse oximetry

被引:2
|
作者
Ferrera, F. Magadan [1 ]
Ferrero, F. J. [1 ]
Blanco, C. [1 ]
Viera, J. C. [1 ]
Vega, M. G. [1 ]
Blanco, J. R. [1 ]
机构
[1] Univ Oviedo, Dept Elect Engn, Campus Viesques,Sede 3, Gijon, Spain
关键词
Pulse Oximetry; hemoglobin; oxygen saturation; DSP;
D O I
10.1109/IMTC.2006.328626
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monitoring the arterial oxygen saturation is very important to defect hypoxemia, as it is the mayor final cause of anaesthetic deaths, and even when the episode is not fatal it can result in irreversible brain damage. This Work presents the design of a low-cost instrument for continuously monitoring the arterial oxygen saturation level in the patient's blood Two sources of light originate from the probe at two wavelengths (650nm and 940nm). The light is partly absorbed by hemoglobin, by amounts which differ depending on its saturation of oxygen. By calculating the light absorption at the two wavelengths the processor can compute the proportion of oxygenated hemoglobin.
引用
收藏
页码:573 / +
页数:2
相关论文
共 50 条
  • [21] LOW-COST PSUEDO RANDOM PULSE GENERATOR
    FUNKE, ER
    SHEWCHUK, A
    JAMES, E
    MEDICAL RESEARCH ENGINEERING, 1969, 8 (03) : 43 - &
  • [22] Experimental Low-Cost Short Pulse Generators
    De Angelis, A.
    Dionigi, M.
    Giglietti, R.
    Carbone, P.
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 259 - 264
  • [23] A LOW-COST PULSE SOURCE FOR CONTINUOUS DUTY
    MULIERI, LA
    WEISSMAN, A
    JOURNAL OF THE EXPERIMENTAL ANALYSIS OF BEHAVIOR, 1961, 4 (02) : 118 - 118
  • [24] NONCONTACTING LOW-COST INSTRUMENT FOR FILM THICKNESS MEASUREMENT
    ROOT, LF
    KAUFMAN, I
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (06) : 1014 - 1019
  • [25] Low-cost airports for low-cost airlines: Flexible design to manage the risks
    De Neufville, Richard
    TRANSPORTATION PLANNING AND TECHNOLOGY, 2008, 31 (01) : 35 - 68
  • [26] Low-cost instrument for oscillometric blood pressure measurement
    Wongjan, Anan
    Julsereewong, Prasit
    Julsereewong, Amphawan
    ICIC Express Letters, Part B: Applications, 2015, 6 (05): : 1259 - 1265
  • [27] Low-cost radon monitoring with validation by a reference instrument
    Jacob, Mbarndouka Taamte
    Francois, Koyang
    Dieu Souffit, Gondji
    Modibo, Oumar Bobbo
    Yerima Abba, Hamadou
    Michaux, Kountchou Noube
    Saidou
    Tokonami, Shinji
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2023, 51 (01) : 68 - 83
  • [28] NEW LOW-COST INSTRUMENT FOR SOLIDS FLOW MEASUREMENT
    GREEN, RG
    KWAM, HK
    BECK, MS
    JOHN, R
    KAUTSCHUK GUMMI KUNSTSTOFFE, 1978, 31 (04): : 257 - 258
  • [29] The low-cost instrument with LabVIEW and DB25
    Prommee, Witoon
    Somchaiwong, Nitipong
    Jeenawong, Suchitra
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 4908 - +
  • [30] Fabricating a Low-Cost Raman Spectrometer to Introduce Students to Spectroscopy Basics and Applied Instrument Design
    Emmanuel, Neethu
    Nair, Raji B.
    Abraham, Bini
    Yoosaf, Karuvath
    JOURNAL OF CHEMICAL EDUCATION, 2021, 98 (06) : 2109 - 2116