Design of a low-cost instrument for pulse oximetry

被引:2
|
作者
Ferrera, F. Magadan [1 ]
Ferrero, F. J. [1 ]
Blanco, C. [1 ]
Viera, J. C. [1 ]
Vega, M. G. [1 ]
Blanco, J. R. [1 ]
机构
[1] Univ Oviedo, Dept Elect Engn, Campus Viesques,Sede 3, Gijon, Spain
关键词
Pulse Oximetry; hemoglobin; oxygen saturation; DSP;
D O I
10.1109/IMTC.2006.328626
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monitoring the arterial oxygen saturation is very important to defect hypoxemia, as it is the mayor final cause of anaesthetic deaths, and even when the episode is not fatal it can result in irreversible brain damage. This Work presents the design of a low-cost instrument for continuously monitoring the arterial oxygen saturation level in the patient's blood Two sources of light originate from the probe at two wavelengths (650nm and 940nm). The light is partly absorbed by hemoglobin, by amounts which differ depending on its saturation of oxygen. By calculating the light absorption at the two wavelengths the processor can compute the proportion of oxygenated hemoglobin.
引用
收藏
页码:573 / +
页数:2
相关论文
共 50 条
  • [1] Design of a Low-cost Pulse Oximeter
    Gao, Xiaoming
    You, Xia
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, ELECTRONIC, INDUSTRIAL AND CONTROL ENGINEERING, 2014, 5 : 909 - 913
  • [2] Design and Evaluation of a Low-Cost Smartphone Pulse Oximeter
    Petersen, Christian L.
    Chen, Tso P.
    Ansermino, J. Mark
    Dumont, Guy A.
    SENSORS, 2013, 13 (12): : 16882 - 16893
  • [3] Design of a low-cost optical instrument for pH fluorescence measurements
    Ferrero Martin, Francisco Javier
    Campo Rodriguez, Juan Carlos
    Alvarez Anton, Juan Carlos
    Viera Perez, Juan Carlos
    Sanchez-Barragan, Israel
    Costa-Fernandez, Jose Manuel
    Sanz-Medel, Alfredo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (04) : 1215 - 1221
  • [4] Design of a low-cost ultrasonic testing instrument for battery metrology
    Amsterdam, Sam
    Chang, Wesley
    ELECTROCHIMICA ACTA, 2025, 524
  • [5] Low-cost frequency-domain photon migration instrument for tissue spectroscopy, oximetry, and imaging
    Yang, YS
    Liu, HL
    Li, XD
    Chance, B
    OPTICAL ENGINEERING, 1997, 36 (05) : 1562 - 1569
  • [6] Ultra-low-cost clinical pulse oximetry
    2013, Institute of Electrical and Electronics Engineers Inc., United States
  • [7] Ultra-Low-Cost Clinical Pulse Oximetry
    Petersen, Christian L.
    Gan, Heng
    MacInnis, Martin J.
    Dumont, Guy A.
    Ansermino, J. Mark
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2874 - 2877
  • [8] Design and validation of pulse oximetry for low saturation
    Mannheimer, PD
    ANESTHESIA AND ANALGESIA, 2002, 94 (01): : S21 - S25
  • [9] Design of low-cost digital pulse processing unit for gamma spectrometry
    Shaker, Hesham H.
    Salama, S.
    Kasban, H.
    Saleh, A. A.
    Dessouky, M.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (04)
  • [10] Design of a low-cost water quality assessment device based on a reference instrument
    Taamte, Jacob Mbarndouka
    Danwe, Yvette Frida
    Signing, Vitrice Ruben Folifack
    Gondji, Dieu Souffit
    Koyang, Francois
    Saidou
    URBAN WATER JOURNAL, 2025, 22 (04) : 397 - 418