Temperature effects in exchange-biased planar hall sensors for bioapplications

被引:15
|
作者
Damsgaard, C. D. [1 ]
Dalslet, B. T. [1 ]
Freitas, S. C. [2 ,3 ]
Freitas, P. P. [2 ,3 ]
Hansen, M. F. [1 ]
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, DTU Nanotech, DK-2800 Lyngby, Denmark
[2] INESC Microsyst & Nanotechnol, P-1000029 Lisbon, Portugal
[3] Inst Super Tecn, Dept Phys, P-1000 Lisbon, Portugal
关键词
Magnetic biosensors; Planar Hall effect; Anisotropic magnetoresistance; Exchange bias; MAGNETIC MICROBEAD;
D O I
10.1016/j.sna.2009.03.024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The temperature dependence of exchange biased planar Hall effect sensors is investigated between T = -10 and 70 degrees C. it is shown that a single domain model describes the system well and that the temperature coefficient of the low-field sensitivity at T = 25 degrees C is 0.32%/degrees C. A procedure for temperature correction by use of a reference sensor is demonstrated. Consequences for magnetic biosensing are exemplified with calculations on M-280 Dynabeads (R). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [21] Bimodal distribution of blocking temperature in exchange-biased ferromagnetic/antiferromagnetic bilayers
    Baltz, V.
    Rodmacq, B.
    Zarefy, A.
    Lechevallier, L.
    Dieny, B.
    PHYSICAL REVIEW B, 2010, 81 (05)
  • [22] Optimization of exchange-biased Heusler alloys
    Endo, H.
    Hirohata, A.
    Nakayama, T.
    Grady, K. O'
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2011, 44 (14)
  • [23] Relaxation times in exchange-biased nanostructures
    Mejía-López, J
    Altbir, D
    Schuller, IK
    APPLIED PHYSICS LETTERS, 2003, 83 (02) : 332 - 334
  • [24] Setting temperature effect in polycrystalline exchange-biased IrMn/CoFe bilayers
    Fernandez-Outon, L. E.
    Araujo Filho, M. S.
    Araujo, R. E.
    Ardisson, J. D.
    Macedo, W. A. A.
    JOURNAL OF APPLIED PHYSICS, 2013, 113 (17)
  • [25] Magnetisation processes in exchange-biased systems
    O'Grady, K
    Owen, NW
    Hughes, T
    Laidler, H
    Petford-Long, AK
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2001, 226 : 1798 - 1799
  • [26] Asymmetric magnetoimpedance in exchange-biased systems
    Gazola, J. P.
    Santos, M. S.
    de Andrade, A. M. H.
    Harres, A.
    da Silva, R. B.
    Rigue, J. N.
    Carara, M.
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2024, 36 (32)
  • [27] Exchange-biased nanocomposite ferromagnetic insulator
    Zhang, Ji
    Zhou, Jingtian
    Luo, Zhen-Lin
    Chen, Y. B.
    Zhou, Jian
    Lin, Weiwei
    Lu, Ming-Hui
    Zhang, Shan-Tao
    Gao, Chen
    Wu, Di
    Chen, Yan-Feng
    PHYSICAL REVIEW B, 2020, 101 (01)
  • [28] Temperature dependence of ferromagnetic resonance in permalloy/NiO exchange-biased films
    Dubowik, J
    Stobiecki, F
    Goscianska, I
    Lee, YP
    Paetzold, A
    Röll, K
    EUROPEAN PHYSICAL JOURNAL B, 2005, 45 (02): : 283 - 288
  • [29] Temperature effect in polycrystalline exchange-biased bilayers: A Monte Carlo study
    Maitre, A.
    Ledue, D.
    Barbe, F.
    Patte, R.
    JOURNAL OF APPLIED PHYSICS, 2012, 111 (07)
  • [30] Unusual phenomena in exchange-biased nanostructures
    Schuller, IK
    MRS BULLETIN, 2004, 29 (09) : 642 - 646