Exergoeconomic and environmental analyses of CO2/NH3 cascade refrigeration systems equipped with different types of flash tank intercoolers

被引:196
|
作者
Mosaffa, A. H. [1 ]
Farshi, L. Garousi [2 ]
Ferreira, C. A. Infante [3 ]
Rosen, M. A. [4 ]
机构
[1] Azarbaijan Shahid Madani Univ, Dept Mech Engn, Tabriz, Iran
[2] Univ Tabriz, Fac Mech Engn, Tabriz, Iran
[3] Delft Univ Technol, Dept Proc & Energy, NL-2628 CB Delft, Netherlands
[4] Univ Ontario Inst Technol, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
关键词
Cascade refrigeration system; CO2/NH3; Exergoeconomic analysis; Environmental analysis; Optimization; Flash tank; HEAT-PUMP SYSTEM; THERMODYNAMIC ANALYSIS; MULTIOBJECTIVE OPTIMIZATION; ENERGY; CO2; TEMPERATURE; CONDENSER; DESIGN; COSTS;
D O I
10.1016/j.enconman.2016.03.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
Exergoeconomic and environmental analyses are presented for two CO2/NH3 cascade refrigeration systems equipped with (1) two flash tanks and (2) a flash tank along with a flash intercooler with indirect subcooler. A comparative study is performed for the proposed systems, and optimal values of operating parameters of the system are determined that maximize the coefficient of performance (COP) and exergy efficiency and minimize the total annual cost. The operating parameters considered include condensing temperatures of NH3 in the condenser and CO3 in the cascade heat exchanger, the evaporating temperature of CO2 in the evaporator, the temperature difference in the cascade heat exchanger, the intermediate pressure of the flash tank in the CO2 low-temperature circuit, the mass flow rate ratio in the flash intercooler and the degree of superheating of the CO2 at the evaporator outlet. The total annual cost includes the capital, operating and maintenance costs and the penalty cost of GHG emission. The results show that, the total annual cost rate for system 1 is 11.2% and 11.9% lower than that for system 2 referring to thermodynamic and economic optimizations, respectively. For thermodynamic and cost optimal design condition the COP and exergy efficiency of both systems are almost the same. Finally, in order to obtain the best balance between exergy destruction cost and capital cost, the exergoeconomic factor is defined for each component of proposed systems, for cases in which the system operates at the best performance conditions. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:442 / 453
页数:12
相关论文
共 50 条
  • [41] Gas-permeable hydrophobic membranes enable transport of CO2 and NH3 to improve performance of bioelectrochemical systems
    Sleutels, Tom H. J. A.
    Hoogland, Biense J.
    Kuntke, Philipp
    ter Heijne, Annemiek
    Buisman, Cees J. N.
    Hamelers, Hubertus V. M.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2016, 2 (04) : 743 - 748
  • [42] HEATS OF ADSORPTION OF CO2 AND NH3 ON SYNTHETIC ZEOLITES OF VARIOUS STRUCTURAL TYPES .1. AMMONIA ON SODIUM AND LITHIUM ZEOLITES
    KHVOSHCHEV, SS
    VASILEVA, EA
    BULLETIN OF THE ACADEMY OF SCIENCES OF THE USSR DIVISION OF CHEMICAL SCIENCE, 1982, 31 (05): : 860 - 864
  • [43] N2O, CO2 and NH3 emission from dung of bovine with different percentage of crude protein in diet
    Hernandez-Tapia, Nadia
    Salinas-Ruiz, Josafhat
    Saynes-Santillan, Vinisa
    Ayala-Rodriguez, Julio M.
    Hernandez-Rosas, Francisco
    Velasco-Velasco, Joel
    REVISTA INTERNACIONAL DE CONTAMINACION AMBIENTAL, 2019, 35 (03): : 597 - 608
  • [44] Thermodynamic, Economic, and Environmental Comparison Between the Direct and Indirect CO2 Refrigeration Cycle With Conventional Indirect NH3 Cycle With Considering a Heat Recovery System in an Ice Rink: A Case Study
    Momeni, Hossien
    Keshtkar, Mohammad Mehdi
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2020, 142 (01):
  • [45] ENERGY, ENVIRONMENTAL, AND EXERGOECONOMIC (3E) ANALYSIS OF TRANSCRITICAL CO2 BOOSTER AND PARALLEL COMPRESSION SUPERMARKET REFRIGERATION CYCLES IN CLIMATE ZONES OF TÜRKİYE
    Caliskan, Oguz
    Ersoy, H. Kursad
    KONYA JOURNAL OF ENGINEERING SCIENCES, 2024, 12 (01):
  • [46] Effects of O2/CO/CO2 on NH3 reducing NO at 1073-1773 K in different flow reactors-Part II: The effects of CO, CO2 and the complex atmosphere
    Chen, Jun
    Fan, Weidong
    Wu, Xiaofeng
    Liu, Songlin
    Guo, Hao
    Liu, Zhuang
    Wang, Xin
    FUEL, 2021, 288
  • [47] HEATS OF ADSORPTION OF CO2 AND NH3 ON SYNTHETIC ZEOLITES OF DIFFERENT STRUCTURAL TYPES .7. AMMONIA AND CARBON-DIOXIDE ON MAGNESIUM-CALCIUM FAUJASITES AND CHABASITES
    ZVEREV, AV
    KHVOSHCHEV, SS
    BULLETIN OF THE ACADEMY OF SCIENCES OF THE USSR DIVISION OF CHEMICAL SCIENCE, 1986, 35 (10): : 1998 - 2001
  • [48] Effects of O2/CO/CO2 on NH3 reducing NO at 10731773 K in different flow reactors-Part Ⅰ: The effect of O2
    Chen, Jun
    Fan, Weidong
    Wu, Xiaofeng
    Liu, Songlin
    Guo, Hao
    Liu, Zhuang
    Wang, Xin
    Fuel, 2021, 283
  • [49] CO2 and NH3 emissions and water consumption at mechanically ventilated finishing pig house in Beijing equipped with pull-plug manure removal system
    Wang M.
    Liu J.
    Zhao W.
    Chen Z.
    Ren K.
    Cui X.
    Wang G.
    Wu Z.
    Wu, Zhonghong (wuzhh@cau.edu.cn), 1600, Chinese Society of Agricultural Engineering (33): : 152 - 160
  • [50] HEATS OF ADSORPTION OF CO2 AND NH3 ON SYNTHETIC ZEOLITES OF DIFFERENT STRUCTURAL TYPES .3. CO2 ADSORPTION ON LI-FORMS, NA-FORMS, AND K-FORMS OF X-ZEOLITES AND Y-ZEOLITES
    VASILEVA, EA
    KHVOSHCHEV, SS
    KARETINA, IV
    BULLETIN OF THE ACADEMY OF SCIENCES OF THE USSR DIVISION OF CHEMICAL SCIENCE, 1984, 33 (09): : 1768 - 1772