Roentgenographic features of digitized clinical orthopaedic radiographs of follow-up after total hip arthroplasty

被引:0
|
作者
Audenino, AL [1 ]
Zanetti, EM [1 ]
Calderale, PM [1 ]
机构
[1] Politecn Torino, Dipartimento Meccan, I-10129 Turin, Italy
关键词
D O I
10.1006/rtim.1997.0074
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
When a patient undergoes an arthroprosthesis implant, the stresses acting on the bone are redistributed, and correspondingly, the bone density adjacent to the entire prosthesis changes its pattern. In order to study these phenomena an automatic methodology has been developed: this methodology is based on the bone density measured on X-ray. The method is compared to other bone densitometry methods and to more recent hone remodeling pattern recognition methods; it turns out to be cost-effective and it has the advantage of allowing back-dated investigation exploiting the numerous existing radiograph records relative to arthroplastic followup. The results of the set-up videodensitometric analysis show the method not only has diagnostic capability, but also can effectively support prostheses designers; moreover, the results obtained offer a capable support to real-time observation of remodeling processes and to the biomechanical assessment of the behavior of bone implant systems. For the clinical practice a risk index has been set up in order to systematize the numerous data collected from the measuring mesh grids and to monitor dangerous situations, which can end in implant failure. (C) 1997 Academic Press Limited.
引用
收藏
页码:399 / 413
页数:15
相关论文
共 50 条
  • [41] RECOVERY IN HORIZONTAL GAIT AFTER HIP RESURFACING VS. TOTAL HIP ARTHROPLASTY AT 6-MONTH FOLLOW-UP - A RANDOMIZED CLINICAL TRIAL
    Jensen, C.
    Aagaard, P.
    Overgaard, S.
    OSTEOARTHRITIS AND CARTILAGE, 2012, 20 : S99 - S99
  • [42] Clinical and radiographic outcomes after total hip arthroplasty with the NANOS neck preserving hip stem: a 10 to 16-year follow-up study
    Vincenzo De Santis
    Nadia Bonfiglio
    Mattia Basilico
    Greta Tanzi Germani
    Maria Rosaria Matrangolo
    Angelo Carosini
    Giuseppe Malerba
    Giulio Maccauro
    BMC Musculoskeletal Disorders, 22
  • [43] Telephone Follow-Up by Nurse After Total Knee Arthroplasty Results of a Randomized Clinical Trial
    Szots, Kirsten
    Konradsen, Hanne
    Solgaard, Soren
    Ostergaard, Birte
    ORTHOPAEDIC NURSING, 2016, 35 (06) : 411 - 420
  • [44] ROENTGENOGRAPHIC EVALUATION OF GEOMETRIC TOTAL KNEE ARTHROPLASTY WITH A 6-YEAR AVERAGE FOLLOW-UP PERIOD
    TORISU, T
    MORITA, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (202) : 125 - 134
  • [45] 8-year follow-up after cementless hip arthroplasty with a second generation spongy metal total hip replacement
    Gollwitzer, Hans
    Gerdesmeyer, Ludger
    Horn, Carsten
    Diehl, Peter
    Toepfer, Andreas
    Gradinger, Reiner
    HIP INTERNATIONAL, 2009, 19 (04) : 359 - 366
  • [46] Hydrotherapy after total knee arthroplasty. A follow-up study
    Giaquinto, S.
    Ciotola, E.
    Dall'Armi, V.
    Margutti, F.
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2010, 51 (01) : 59 - 63
  • [47] Rehabilitation following total hip arthroplasty evaluation over short follow-up time: Randomized clinical trial
    Umpierres, Carolina Sant'anna
    Ribeiro, Tiango Aguiar
    Marchisio, Angela Elisabete
    Galvao, Livia
    Kras Borges, Ingrid Nemitz
    de Souza Macedo, Carlos Alberto
    Galia, Carlos Roberto
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2014, 51 (10): : 1567 - 1578
  • [48] Fourteen Year Follow-Up of Randomized Clinical Trials of Active Robotic-Assisted Total Hip Arthroplasty
    Bargar, William L.
    Parise, Carol A.
    Hankins, Andrea
    Marlen, Natalie A.
    Campanelli, Valentina
    Netravali, Nathan A.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03): : 810 - 814
  • [49] CLINICAL-RESULTS WITH A HYBRID TOTAL HIP-ARTHROPLASTY - A 3-6 YEAR FOLLOW-UP
    HELFEN, M
    MALZER, U
    PETERS, P
    GRISS, P
    HIMMELMANN, G
    WEBER, E
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1993, 131 (06): : 578 - 584
  • [50] Assessment of variation in position of the leg during follow-up total hip replacement (THR) radiographs
    Murphy M.
    Fitzpatrick D.
    Rice J.
    European Journal of Orthopaedic Surgery & Traumatology, 2004, 14 (4) : 221 - 224