Compressed sensing real-time cine imaging for assessment of ventricular function, volumes and mass in clinical practice

被引:52
|
作者
Vermersch, Mathilde [1 ]
Longere, Benjamin [1 ]
Coisne, Augustin [2 ,3 ]
Schmidt, Michaela [4 ]
Forman, Christoph [4 ]
Monnet, Aurelien [4 ]
Pagniez, Julien [1 ]
Silvestri, Valentina [1 ]
Simeone, Arianna [1 ]
Cheasty, Emma [5 ]
Montaigne, David [2 ,3 ]
Pontana, Francois [1 ,3 ]
机构
[1] CHU Lille, Inst Coeur Poumon, Dept Cardiovasc Radiol, Blvd Pr Jules Leclercq, F-59037 Lille, France
[2] CHU Lille, Dept Clin Physiol & Echocardiog, Lille, France
[3] EGID, Inst Pasteur Lille, INSERM UMR 1011, FR3508, F-59000 Lille, France
[4] Siemens Healthcare GmbH, Erlangen, Germany
[5] St Bartholomews Hosp, Dept Cardiovasc Imaging, London, England
关键词
Heart ventricles; Magnetic resonance imaging; Breath holding; ITERATIVE RECONSTRUCTION; DIASTOLIC FUNCTION; MRI; RESOLUTION; HEART; CMR;
D O I
10.1007/s00330-019-06341-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted in order to evaluate the accuracy of a compressed sensing (CS) real-time single-breath-hold cine sequence for the assessment of left and right ventricular functional parameters in daily practice. Methods Cardiac magnetic resonance (CMR) cine images were acquired from 100 consecutive patients using both the reference segmented multi-breath-hold steady-state free precession (SSFP) acquisition and a prototype single-breath-hold real-time CS sequence, providing the same slice number, position, and thickness. For both sequences, the left (LV) and right ventricular (RV) ejection fractions (EF) and end-diastolic volumes (EDV) were assessed as well as LV mass (LVM). The visualization of wall-motion disorders (WMD) and signal void related to mitral or tricuspid regurgitation was also analyzed. Results The CS sequence mean scan time was 23 +/- 6 versus 510 +/- 109 s for the multi-breath-hold SSFP sequence (p < 0.001). There was an excellent correlation between the two sequences regarding mean LVEF (r = 0.995), LVEDV (r = 0.997), LVM (r = 0.981), RVEF (r = 0.979), and RVEDV (r = 0.983). Moreover, inter- and intraobserver agreements were very strong with intraclass correlations of 0.96 and 0.99, respectively. On CS images, mitral or tricuspid regurgitation visualization was good (AUC = 0.85 and 0.81, respectively; ROC curve analysis) and wall-motion disorder visualization was excellent (AUC >= 0.97). Conclusion CS real-time single-breath-hold cine imaging reduces CMR scan duration by almost 20 times in daily practice while providing reliable measurements of both left and right ventricles. There was no clinically relevant information loss regarding valve regurgitation and wall-motion disorder depiction. Key Points Compressed sensing single-breath-hold real-time cine imaging is a reliable sequence in daily practice. Fast CS real-time imaging reduces CMR scan time and improves patient workflow. There is no clinically relevant information loss with CS regarding heart valve regurgitation or wall-motion disorders.
引用
收藏
页码:609 / 619
页数:11
相关论文
共 50 条
  • [21] Accuracy of compressed sensing for left ventricular mass and volumes
    Suzanne Lydiard
    Andreas Greiser
    Michaela Schmidt
    Michael O Zenge
    Mariappan S Nadar
    Alistair Young
    Brett R Cowan
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [22] Compressed Sensing Real-Time Cine Reduces CMR Arrhythmia-Related Artifacts
    Longere, Benjamin
    Allard, Paul-Edouard
    Gkizas, Christos, V
    Coisne, Augustin
    Hennicaux, Justin
    Simeone, Arianna
    Schmidt, Michaela
    Forman, Christoph
    Toupin, Solenn
    Montaigne, David
    Pontana, Francois
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [23] Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR Imaging
    Barkhausen, J
    Goyen, M
    Rühm, SG
    Eggebrecht, H
    Debatin, JF
    Ladd, ME
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) : 731 - 735
  • [24] Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function
    Goebel, Juliane
    Nensa, Felix
    Schemuth, Haemi P.
    Maderwald, Stefan
    Gratz, Marcel
    Quick, Harald H.
    Schlosser, Thomas
    Nassenstein, Kai
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (02) : 366 - 374
  • [25] Assessment of right ventricular volumes and function by 3D real-time transthoracic echocardiography in children
    Hascouet, S.
    Brierre, G.
    Caudron, G.
    Abadir, S.
    Dulac, Y.
    Paranon, S.
    Ohanessian, G.
    Acar, P.
    EUROPEAN HEART JOURNAL, 2009, 30 : 55 - 56
  • [26] Assessment of left ventricular volumes and function by cine-MR imaging depending on the investigator's experience
    Bailly, A.
    Lipiecki, J.
    Chabrot, P.
    Alfidja, A.
    Garcier, J. M.
    Ughetto, S.
    Ponsonnaille, J.
    Boyer, L.
    SURGICAL AND RADIOLOGIC ANATOMY, 2009, 31 (02) : 113 - 120
  • [27] Multiblock compressed sensing imaging in real time
    Li Hu
    Liu Xue-Feng
    Yao Xu-Ri
    Liu Fan
    Dou Shen-Cheng
    Hu Tai
    Zhai Guang-Jie
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2023, 42 (01) : 61 - 71
  • [28] Assessment of left ventricular volumes and function by cine-MR imaging depending on the investigator’s experience
    A. Bailly
    J. Lipiecki
    P. Chabrot
    A. Alfidja
    J. M. Garcier
    S. Ughetto
    J. Ponsonnaille
    L. Boyer
    Surgical and Radiologic Anatomy, 2009, 31 : 113 - 120
  • [30] Quantitative assessment of left ventricular function with interactive real-time spiral and radial MR imaging
    Spuentrup, E
    Schroeder, J
    Mahnken, AH
    Schaeffter, T
    Botnar, RM
    Kühl, HP
    Hanrath, P
    Günther, RW
    Buecker, A
    RADIOLOGY, 2003, 227 (03) : 870 - 876