3D breath-hold contrast-enhanced MRA: A preliminary experience in aorta and iliac vascular disease

被引:10
|
作者
Shetty, AN
Shirkhoda, A
Bis, KG
Ellwood, R
Li, DB
机构
[1] William Beaumont Hosp, Dept Radiol, Royal Oak, MI 48073 USA
[2] Mallinckrodt Inst Radiol, St Louis, MO USA
关键词
magnetic resonance imaging; angiography; (MRA); aorta; abdominal; blood vessels; diseases; breath-holding;
D O I
10.1097/00004728-199803000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our goal was to describe a 3D breath-hold (3D BH) contrast-enhanced MRA technique and apply the technique to patients with known or suspected aortic and iliac artery disease. Method: A fat-suppressed 3D GRE pulse sequence was designed with a total of 16 partition encodings. This took <24 s for data acquisition in the abdomen and pelvis and was easily achieved during a single breath-hold. The technique was applied to 26 patients who presented with either known or suspected abdominal aortic or iliac vascular diseases. For comparison, in 19 patients a 2D TOF MRA pulse sequence with a traveling saturation band was used. Angiographic correlation was made in 18 studies. Results: The 3D BH MRA was easily applicable in the evaluation of vascular anatomy and pathology. In three cases, it was superior to 2D TOF and conventional angiography for visualizing clot within the wall of an aneurysm in the abdominal aorta. In 20 cases, both MRA techniques overestimated the degree of stenosis in the lower peripheral vessels; however, this was more pronounced on 2D TOF. In five cases, the aneurysm wall was clearly defined by 3D BH MRA, whereas there was considerable signal loss in 2D TOF due to complex flow. With 3D BH MRA, the entire vessel territory both in abdominal aorta and in iliac vessels was visualized in all cases without signal falloff in the FOV. Breath-holding provided static images of the vessels that were free of blurring due to respiratory motion. Conclusion: Preliminary experience suggests that 3D BH with its distinct advantage of speed may serve as a useful screening tool for patients who cannot have conventional angiography or tolerate a lengthy MR examination of the abdominal aorta and iliac arteries.
引用
收藏
页码:179 / 185
页数:7
相关论文
共 50 条
  • [41] Motion matched K-space sampling for breath-hold contrast enhanced 3D coronary MR angiography
    Wang, Y
    Lee, HM
    Winchester, PA
    Yang, Z
    Bergman, G
    Shaknovich, A
    RADIOLOGY, 1998, 209P : 355 - 355
  • [42] Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging - Initial experience
    Kessler, W
    Laub, G
    Achenbach, S
    Ropers, D
    Moshage, W
    Daniel, WG
    RADIOLOGY, 1999, 210 (02) : 566 - 572
  • [43] Motion of the distal renal artery during three-dimensional contrast-enhanced breath-hold MRA (vol 16, pg 685, 2002)
    Boudewijn, G
    Vasbinder, C
    Maki, JH
    Nijenhuis, RJ
    Leiner, T
    Wilson, GJ
    Kessels, AGH
    Lemaire, EELE
    Kaandorp, DW
    Ho, KYJAM
    van Engelshoven, JMA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 388 - 388
  • [44] Optimization of contrast material administration for breath-hold 3D MR angiography of the abdominal vessels
    Kopka, L
    Vosshenrich, R
    Rodenwaldt, J
    Grabbe, EH
    RADIOLOGY, 1997, 205 : 673 - 673
  • [45] Dynamic contrast-enhanced breath-hold MR imaging of thoracic malignancy using cardiac compensation
    Low, RN
    Sigeti, JS
    Song, SYT
    Shimakawa, A
    Pelc, NJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 625 - 631
  • [46] Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts
    Vrachliotis, TG
    Bis, KG
    Aliabadi, D
    Shetty, AN
    Safian, R
    Simonetti, O
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) : 1073 - 1080
  • [47] High-resolution breath-hold contrast-enhanced MR angiography of the entire carotid circulation
    Carr, JC
    Ma, J
    Desphande, V
    Pereles, S
    Laub, G
    Finn, JP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) : 543 - 549
  • [48] Diagnostic performance of contrast-enhanced breath-hold MR imaging in the detection and differentiation of renal lesions
    Krestin, GP
    Hauser, M
    Goehde, SC
    Knecht, M
    HuchBoeni, RA
    Debatin, JF
    RADIOLOGY, 1996, 201 : 104 - 104
  • [49] Takayasu arteritis: Evaluation with breath-hold contrast-enhanced three-dimensional MR angiography
    Yamada, I
    Nakagawa, T
    Himeno, Y
    Shibuya, H
    Numano, F
    RADIOLOGY, 1998, 209P : 495 - 495
  • [50] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Marcus R Makowski
    Andrea J Wiethoff
    Christian HP Jansen
    Sergio Uribe
    Victoria Parish
    Andreas Schuster
    Rene M Botnar
    Aaron Bell
    Christoph Kiesewetter
    Reza Razavi
    Tobias Schaeffter
    Gerald F Greil
    Journal of Cardiovascular Magnetic Resonance, 14