Perioperative Noninvasive Blood Pressure Monitoring

被引:24
|
作者
Kuck, Kai [1 ]
Baker, Philip D. [2 ]
机构
[1] Univ Utah, Sch Med, Dept Anesthesiol, 30 N 1900 E Room 3c444, Salt Lake City, UT 84132 USA
[2] Diagnost Imaging Northwest, Portland, OR USA
来源
ANESTHESIA AND ANALGESIA | 2018年 / 127卷 / 02期
关键词
OSCILLOMETRIC MAXIMUM;
D O I
10.1213/ANE.0000000000002619
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The most commonly monitored variable for perioperative hemodynamic management is blood pressure. Several indirect noninvasive blood pressure monitoring techniques have been developed over the last century, including intermittent techniques such as auscultation (Riva-Rocci and Korotkoff) and oscillometry (Marey) and continuous techniques. With the introduction of automated noninvasive blood pressure devices in the 1970s, the oscillometric technique quickly became and remains the standard for automated, intermittent blood pressure measurement. It tends to estimate more extreme high and low blood pressures closer to normal than what invasive measurements indicate. The accuracy of the oscillometric maximum amplitude algorithm for estimating mean arterial pressure is affected by multiple factors, including the cuff size and shape, the shape of the arterial compliance curve and arterial pressure pulse, and pulse pressure itself. Additionally, the technique typically assumes a consistent arterial compliance and arterial pressure pulse, thus changes in arterial compliance and arrhythmias that lead to variation in the pressure pulse can affect accuracy. Volume clamping, based on the Penaz principle, and arterial tonometry provide continuous tracking of the arterial pressure pulse. The ubiquitous use of blood pressure monitoring is in contrast with the lack of evidence for optimal perioperative blood pressure targets.
引用
收藏
页码:408 / 411
页数:4
相关论文
共 50 条
  • [41] NONINVASIVE CONTINUOUS BLOOD-PRESSURE MONITORING BY THE UNLOADING OF VASCULAR WALL
    WANG, MH
    CHEUNG, PW
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1417 - 1418
  • [42] CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITORING IN PATIENTS WITH SLEEP DISORDERS
    PENZEL, T
    MAYER, J
    PETER, JH
    PODSZUS, T
    VOIGT, KH
    VONWICHERT, P
    PHYSIOLOGICAL RESEARCH, 1992, 41 (01) : 11 - 17
  • [43] Applications of 24-hour noninvasive ambulatory blood pressure monitoring
    Tseng, Yung-Zu
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2006, 105 (12) : 955 - 963
  • [44] Noninvasive Monitoring of Blood Pressure Using Optical Ballistocardiography and Photoplethysmograph Approaches
    Chen, Zhihao
    Yang, Xiufeng
    Teo, Ju Teng
    Ng, Soon Huat
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2425 - 2428
  • [45] NONINVASIVE AMBULATORY BLOOD-PRESSURE MONITORING - TECHNICAL POSSIBILITIES AND PROBLEMS
    MEYERSABELLEK, W
    SCHULTE, KL
    GOTZEN, R
    JOURNAL OF HYPERTENSION, 1990, 8 : S3 - S10
  • [46] Hydraulic Coupling A New Method for Noninvasive Intermittent Blood Pressure Monitoring
    Saugel, Bernd
    Kouz, Karim
    Sessler, Daniel I.
    ANESTHESIOLOGY, 2020, 133 (05) : 964 - 966
  • [47] Development of a simulator for the validation of noninvasive blood pressure-monitoring devices
    Doh, Il
    Lim, Hyun Kyoon
    Ahn, Bongyoung
    BLOOD PRESSURE MONITORING, 2016, 21 (03) : 189 - 191
  • [48] NONINVASIVE DOPPLER BLOOD-PRESSURE MONITORING IN THE MONOPLACE HYPERBARIC CHAMBER
    WEAVER, LK
    HOWE, S
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (04): : 304 - 308
  • [49] PHYSIOLOGICAL-ASPECTS OF NONINVASIVE AMBULATORY BLOOD-PRESSURE MONITORING
    PICKERING, TG
    NEWS IN PHYSIOLOGICAL SCIENCES, 1990, 5 : 176 - 179
  • [50] Noninvasive blood oxygen, heartbeat rate, and blood pressure parameter monitoring by photoplethysmography signals
    Ku, Chin-Jung
    Wang, Yuhling
    Chang, Chia-Yu
    Wu, Min-Tse
    Dai, Sheng-Tong
    Liao, Lun-De
    HELIYON, 2022, 8 (11)