The button inhalable aerosol sampler with a curved porous inlet recently was developed and evaluated as a stationary sampler in the laboratory and in the field. The present study focused on investigating its suitability far personal inhalable aerosol sampling. The button sampler was tested at two wind velocities (0.5 and 2.0 m/sec), three particle sizes (7, 29, and 70 mu m) and three orientations to the wind (0, 90, and 180 degrees). The performance characteristics of the button sampler were compared with those of three other personal samplers-the IOM (Institute of Occupational Medicine), GSP, and 37-mm closed-face filter cassette. The experiments were conducted in a wind tunnel with the samplers mounted on a full-size manikin. The direction-specific sampling efficiency of the button sampler was found to be essentially independent of the wind direction and dependent on the wind velocity to a much smaller degree than that of the three other samplers. When direction-averaged, the fit of its sampling efficiency curve to the inhalability curve was found to be better than that of the 37-mm closed-face cassette, comparable with that of the GSP sampler, and less than that of the IOM sampler. The precision of the button sampler was found to be generally equal to or better than the precision of the comparison samplers. it was concluded that the button sampler can be successfully used as a personal inhalable aerosol sampler.
引用
收藏
页码:398 / 404
页数:7
相关论文
共 50 条
  • [1] Performance of the Button Personal Inhalable Sampler for the measurement of outdoor aeroallergens
    Adhikari, A
    Martuzevicius, D
    Reponen, T
    Grinshpun, SA
    Cho, SH
    Sivasubramani, SK
    Zhong, W
    Levin, L
    Kelley, AL
    St Clair, HG
    Lemastersa, G
    ATMOSPHERIC ENVIRONMENT, 2003, 37 (34) : 4723 - 4733
  • [2] A collaborative European study of personal inhalable aerosol sampler performance
    Kenny, LC
    Aitken, R
    Chalmers, C
    Fabries, JF
    GonzalezFernandez, E
    Kromhout, H
    Liden, G
    Mark, D
    Riediger, G
    Prodi, V
    ANNALS OF OCCUPATIONAL HYGIENE, 1997, 41 (02): : 135 - 153
  • [3] Inhalable aerosol selector for the CIP 10 personal aerosol sampler
    Gorner, P.
    Wrobel, R.
    Roger, F.
    Fabries, J.-F.
    Journal of Aerosol Science, 1999, 30 (Suppl. 1)
  • [4] Improvements to the design and performance of an ambient inhalable aerosol sampler
    Upton, S.L.
    Mark, D.
    Hall, D.J.
    Journal of Aerosol Science, 1992, 23 (SUPPL 1)
  • [5] Sampling characteristics of modified personal inhalable sampler inlets
    Stancliffe, J.D.
    Kenny, L.C.
    Journal of Aerosol Science, 1997, 28 (SUPPL. 1)
  • [6] Evaluation of the use of an SKC button inhalable aerosol sampler with a Grimm aerosol monitor to determine air concentrations of subtilisin
    Cross, Jason B.
    Larson, Rodney R.
    Pahler, Leon F.
    Sleeth, Darrah K.
    JOURNAL OF CHEMICAL HEALTH & SAFETY, 2014, 21 (06): : 4 - 13
  • [7] Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery
    Lee, Eun Gyung
    Grimson, Peter J.
    Chisholm, William P.
    Kashon, Michael L.
    He, Xinjian
    L'Orange, Christian
    Volckens, John
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2019, 16 (03) : 250 - 257
  • [8] Relationship between indoor and outdoor bioaerosols collected with a button inhalable aerosol sampler in urban homes
    Lee, T
    Grinshpun, SA
    Martuzevicius, D
    Adhikari, A
    Crawford, CM
    Luo, J
    Reponen, T
    INDOOR AIR, 2006, 16 (01) : 37 - 47
  • [9] High efficiency CIP 10-I personal inhalable aerosol sampler
    Gorner, P.
    Wrobel, R.
    Simon, X.
    INHALED PARTICLES X, 2009, 151
  • [10] High efficiency CIP 10-I personal inhalable aerosol sampler
    Gorner, P.
    Wrobel, R.
    Simon, X.
    INHALED PARTICLES X, 2009, 151