Application of microdialysis for on-line coupling of capillary isoelectric focusing with electrospray mass spectrometry on a magnetic sector instrument

被引:0
|
作者
Lamoree, MH [1 ]
van der Hoeven, RAM [1 ]
Tjaden, UR [1 ]
van der Greef, J [1 ]
机构
[1] Leiden Univ, Leiden Amsterdam Ctr Drug Res, Div Analyt Chem, NL-2300 RA Leiden, Netherlands
来源
JOURNAL OF MASS SPECTROMETRY | 1998年 / 33卷 / 05期
关键词
capillary isoelectric focusing; mass spectrometry; microdialysis; protein analysis; carbonic anhydrase;
D O I
10.1002/(SICI)1096-9888(199805)33:5<453::AID-JMS654>3.0.CO;2-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The on-line coupling of capillary isoelectric focusing (CIEF) with electrospray mass spectrometry (MS) by means of microdialysis (MD) for application to three carbonic anhydrase isozymes is described. The dialysis device consisted of a donor and an acceptor compartment that were separated by a flat membrane, and served to clear the CIEF effluent that was directed to the mass spectrometer from ampholytes that were necessary for the establishment of a pH gradient in the IEF capillary. In addition to single-ion monitoring and full-scan experiments, a position-and time-resolved ion counting (PATRIC) detector was used in the static array mode. For CIEF/MD/MS of unknown proteins the minimum amount of analyte required for the analysis was estimated to be in the mid-femtomole range using full-scan MS data acquisition. (C) 1998 John Wiley & Sons, Ltd.
引用
收藏
页码:453 / 460
页数:8
相关论文
共 50 条
  • [21] On-line microdialysis desalting for electrospray ionization-mass spectrometry of proteins and peptides
    Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352, United States
    Rapid Commun. Mass Spectrom., 7 (835-838):
  • [22] Capillary isoelectric focusing electrospray ionization time-of-flight mass spectrometry for protein analysis
    Wei, J
    Lee, CS
    Lazar, IM
    Lee, ML
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (03) : 193 - 197
  • [23] On-line capillary electrophoresis-electrospray mass spectrometry for the analysis of pharmaceuticals
    Cherkaoui, S
    Rudaz, S
    Varesio, E
    Veuthey, JL
    CHIMIA, 1999, 53 (10) : 501 - 505
  • [24] A sheathless nanoflow electrospray interface for on-line capillary electrophoresis mass spectrometry
    Janini, GM
    Conrads, TP
    Wilkens, KL
    Issaq, HJ
    Veenstra, TD
    ANALYTICAL CHEMISTRY, 2003, 75 (07) : 1615 - 1619
  • [25] Open Port Interface for Coupling Capillary Electrophoresis and Mass Spectrometry: Performance Evaluation for Capillary Isoelectric Focusing
    Beloborodov, Stanislav S.
    Schneider, Bradley B.
    Oleschuk, Richard D.
    Le Blanc, J. C. Yves
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2023, 34 (10) : 2107 - 2116
  • [26] Separation and detection of intact noncovalent protein complexes from mixtures by on-line capillary isoelectric focusing-mass spectrometry
    Martinovic, S
    Berger, SJ
    Pasa-Tolic, L
    Smith, RD
    ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5356 - 5360
  • [27] On-line microdialysis of proteins with high-salt buffers for direct coupling of electrospray ionization mass spectrometry and liquid chromatography
    Canarelli, S
    Fisch, I
    Freitag, R
    JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) : 139 - 149
  • [28] Flow-Through Microvial Facilitating Interface of Capillary Isoelectric Focusing and Electrospray Ionization Mass Spectrometry
    Zhong, Xuefei
    Maxwell, E. Jane
    Ratnayake, Chitra
    Mack, Scott
    Chen, David D. Y.
    ANALYTICAL CHEMISTRY, 2011, 83 (22) : 8748 - 8755
  • [29] Capillary isoelectric focusing-electrospray ionization time-of-flight mass spectrometry for protein analysis
    Wei, Jing
    Lee, Cheng S.
    Lazar, Iulia M.
    Lee, Milton L.
    Journal of Microcolumn Separations, 11 (03): : 193 - 197
  • [30] Protein isoforms observed by ultrahigh resolution capillary isoelectric focusing-electrospray ionization mass spectrometry
    Liu, T
    Shao, XX
    Zeng, R
    Xia, QC
    ACTA BIOCHIMICA ET BIOPHYSICA SINICA, 2002, 34 (04): : 423 - 432