Multireflection planar time-of-flight mass analyzer. II: The high-resolution mode

被引:39
|
作者
Verentchikov, AN [1 ]
Yavor, MI [1 ]
Hasin, YI [1 ]
Gavrik, MA [1 ]
机构
[1] Russian Acad Sci, Inst Analyt Instrument Making, St Petersburg 190103, Russia
关键词
Power Supply; Operating Mode; High Vacuum; Intensity Loss; Mass Analyzer;
D O I
10.1134/1.1854828
中图分类号
O59 [应用物理学];
学科分类号
摘要
The feasibility of the high-resolution operating mode in a planar multireflection time-of-flight analyzer that is suggested in Part I of this work is demonstrated. Time-of-flight aberrations, which limit the resolution, are estimated. A resolution as high as 200 000 at a time of flight of 70 ms is achieved in experiments. It is shown that the maximal resolution is limited by the duration of the ion packet generated by the source. The resolution can be improved by closing the ion beam trajectory with the formation of repeating cycles. The number of the cycles depends on the beam intensity losses due to scattering by the residual gas. It seem likely that the resolution can be improved further by using a higher vacuum, refining the ion source, and applying more stable power supplies. (C) 2005 Pleiades Publishing, Inc.
引用
收藏
页码:82 / 86
页数:5
相关论文
共 50 条
  • [11] A high-resolution time-of-flight mass spectrometer for the detection of ultracold molecules
    S.D. Kraft
    J. Mikosch
    P. Staanum
    J. Deiglmayr
    J. Lange
    A. Fioretti
    R. Wester
    M. Weidemüller
    Applied Physics B, 2007, 89 : 453 - 457
  • [12] A high-resolution time-of-flight mass spectrometer for the detection of ultracold molecules
    Kraft, S. D.
    Mikosch, J.
    Staanum, P.
    Deiglmayr, J.
    Lange, J.
    Fioretti, A.
    Wester, R.
    Weidemueller, M.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 89 (04): : 453 - 457
  • [13] Development and application of a high-resolution time-of-flight aerosol mass spectrometer
    Jimenez, Jose L.
    Decarlo, P.
    Kimmel, J. R.
    Huffman, J. A.
    Ulbrich, I.
    Dunlea, Edward
    Trimborn, A.
    Northway, M. J.
    Jayne, John T.
    Aiken, Allison C.
    Gonin, M.
    Fuhrer, K.
    Horvath, T.
    Docherty, Kenneth S.
    Worsnop, Douglas R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 590 - 590
  • [14] Reflection-type high-resolution time-of-flight momentum and energy mapping analyzer
    Wang, Chao
    Kang, Yifan
    Tang, Tiantong
    OPTIK, 2011, 122 (13): : 1207 - 1211
  • [15] A high-resolution time-of-flight energy analyzer for femtosecond electron pulses at 30 keV
    Gliserin, Alexander
    Walbran, Matthew
    Baum, Peter
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (03):
  • [16] NEW HIGH-RESOLUTION ELECTROSTATIC ION MASS ANALYZER USING TIME OF FLIGHT
    HAMILTON, DC
    GLOECKLER, G
    IPAVICH, FM
    LUNDGREN, RA
    SHELDON, RB
    HOVESTADT, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 3104 - 3106
  • [17] HIGH-RESOLUTION TIME-OF-FLIGHT ELECTRON SPECTROMETER
    UEHARA, Y
    USHIROKU, T
    USHIODA, S
    MURATA, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1990, 29 (12): : 2858 - 2863
  • [18] HIGH-RESOLUTION NEUTRON TIME-OF-FLIGHT SPECTROMETER
    MENACHERY, JD
    COUCHELL, GP
    EGAN, JJ
    KEGEL, GHR
    MITTLER, A
    PULLEN, DJ
    SCHIER, WA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (02): : 96 - 96
  • [19] The high-resolution time-of-flight spectrometer TOFTOF
    Unruh, Tobias
    Neuhaus, Juergen
    Petry, Winfried
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (03): : 1414 - 1422
  • [20] HIGH-RESOLUTION TIME-OF-FLIGHT ELECTRONICS SYSTEM
    GRUND, JE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 599 - 604