Full-depth epidermis tomography using a Mirau-based full-field optical coherence tomography

被引:45
|
作者
Tsai, Chien-Chung [1 ]
Chang, Chia-Kai [1 ]
Hsu, Kuang-Yu [1 ]
Ho, Tuan-Shu [1 ]
Lin, Ming-Yi [2 ,3 ]
Tjiu, Jeng-Wei [2 ,3 ]
Huang, Sheng-Lung [1 ,4 ]
机构
[1] Natl Taiwan Univ, Grad Inst Photon & Optoelect, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Natl Taiwan Univ Hosp, Dept Dermatol, Taipei 10764, Taiwan
[3] Natl Taiwan Univ, Coll Med, Taipei 10764, Taiwan
[4] Natl Taiwan Univ, Dept Elect Engn, Taipei 10617, Taiwan
来源
BIOMEDICAL OPTICS EXPRESS | 2014年 / 5卷 / 09期
关键词
STRATUM-CORNEUM THICKNESS; IN-VIVO; CRYSTAL-FIBER; LIGHT; WATER; PIGMENTATION; GENERATION; MICROSCOPY;
D O I
10.1364/BOE.5.003001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With a Gaussian-like broadband light source from high brightness Ce3+:YAG single-clad crystal fiber, a full-field optical coherence tomography using a home-designed Mirau objective realized high quality images of in vivo and excised skin tissues. With a 40 x silicone-oil-immersion Mirau objective, the achieved spatial resolutions in axial and lateral directions were 0.9 and 0.51 mu m, respectively. Such a high spatial resolution enables the separation of lamellar structure of the full epidermis in both the cross-sectional and en face planes. The number of layers of stratum corneum and its thickness were quantitatively measured. This label free and non-invasive optical probe could be useful for evaluating the water barrier of skin tissue in clinics. As a preliminary in vivo experiment, the blood vessel in dermis was also observed, and the flowing of the red blood cells and location of the melanocyte were traced. (C)2014 Optical Society of America
引用
收藏
页码:3001 / 3010
页数:10
相关论文
共 50 条
  • [31] Thermal-light full-field optical coherence tomography
    Vabre, L
    Dubois, A
    Boccara, AC
    OPTICS LETTERS, 2002, 27 (07) : 530 - 532
  • [32] Multiple Delay Lines Full-field Optical Coherence Tomography
    Wang, Jingyu
    Dainty, Christopher
    Podoleanu, Adrian
    1ST CANTERBURY WORKSHOP ON OPTICAL COHERENCE TOMOGRAPHY AND ADAPTIVE OPTICS, 2008, 7139
  • [33] Full-field Fourier-domain optical coherence tomography
    Zvyagin, AV
    Blazkiewicz, P
    Vintrou, J
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 44 - 53
  • [34] Full-field optical coherence tomography with achromatic phase shifter
    Watanabe, Y
    Hayasaka, Y
    Sato, M
    APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 131 - 132
  • [35] Polarization-sensitive full-field optical coherence tomography
    Moneron, Gael
    Boccara, Albert-Laude
    Dubois, Arnaud
    OPTICS LETTERS, 2007, 32 (14) : 2058 - 2060
  • [36] An efficient algorithm used for full-field optical coherence tomography
    Chang, Shoude
    Cai, Xianylang
    Flueraru, Costel
    OPTICS AND LASERS IN ENGINEERING, 2007, 45 (12) : 1170 - 1176
  • [37] A model for full-field optical coherence tomography in scattering media
    Tricoli, Ugo
    Carminati, Remi
    BIOMEDICAL SPECTROSCOPY, MICROSCOPY, AND IMAGING, 2020, 11359
  • [38] Experimental demonstration of full-field quantum optical coherence tomography
    Ibarra-Borja, Zeferino
    Sevilla-Gutierrez, Carlos
    Ramirez-Alarcon, Roberto
    Cruz-Ramirez, Hector
    U'Ren, Alfred B.
    PHOTONICS RESEARCH, 2020, 8 (01) : 51 - 56
  • [39] Human trabeculum imaging with full-field optical coherence tomography
    Stephane, Bertin
    Zwillinger, Stephanie
    Paques, Michel
    Baudouin, Christophe
    Labbe, Antoine
    Borderie, Vincent M.
    Grieve, Kate
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [40] Ultrahigh-resolution full-field optical coherence tomography
    Dubois, A
    Grieve, K
    Moneron, G
    Lecaque, R
    Vabre, L
    Boccara, C
    APPLIED OPTICS, 2004, 43 (14) : 2874 - 2883