Simultaneous electrochemical determination of dopamine and acetaminophen using multiwall carbon nanotubes modified glassy carbon electrode

被引:311
|
作者
Alothman, Zeid Abdullah [1 ]
Bukhari, Nausheen [1 ]
Wabaidur, Saikh Mohammad [1 ]
Haider, Sajjad [2 ]
机构
[1] King Saud Univ, Coll Sci, Dept Chem, Riyadh 11451, Saudi Arabia
[2] King Saud Univ, Coll Engn, Dept Chem Engn, Riyadh 11421, Saudi Arabia
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2010年 / 146卷 / 01期
关键词
Electrochemical method; MWCNTs; Glassy carbon electrode; Dopamine; Acetaminophen; STRIPPING VOLTAMMETRIC DETERMINATION; ASCORBIC-ACID; FABRICATION; DESIGN;
D O I
10.1016/j.snb.2010.02.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive method was investigated for the simultaneous determination of dopamine (DA) and acetaminophen (AP) using acid functionalized multi-wall carbon nanotubes (f-MWCNTs) modified glassy carbon electrodes (GCEs). Both DA and AP were accumulated at the surface of f-MWCNTs modified GCE (under open circuit condition for 30s). In differential pulse voltammetry (DPV) technique both DA and AP give sensitive oxidation peaks at 125 mV and 307 mV, respectively. Under the optimized experimental conditions (such as supporting electrolyte pH, accumulation time and scanning rate, etc.) DA and AP give linear response over the range of 3-200 mu mol L-1 (r=0.992) and 3-300 mu mol L-1 (r=0.989), respectively. The lower detection limits were found to be 0.8 for DA and 0.6 p.mol L-1 for AP. The interfering species such as ascorbic acid (AA), uric acid (UA) and reduced form of Nicotinamide adenine dinucleotide (NADH) showed no interference with the selective determination of DA and AP. The investigated method showed good stability, reproducibility (1.3% (DA) and 2.3% (AP)), repeatability (1.9%) and high recovery in pharmaceutical preparation (1.7% (DA) and 2.7% (AP)), and human serum (1.7% (DA) and 1.9% (AP)). (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:314 / 320
页数:7
相关论文
共 50 条
  • [41] Electrocatalytic Oxidation of Venlafaxine at a Multiwall Carbon Nanotubes-Ionic Liquid Gel Modified Glassy Carbon Electrode and Its Electrochemical Determination
    Ding, Ling
    Li, Lei
    You, Wei
    Gao, Zuo-Ning
    Yang, Tian-Lin
    CROATICA CHEMICA ACTA, 2015, 88 (01) : 81 - 87
  • [42] Electrocatalytic oxidation of quinine sulfate at a multiwall carbon nanotubes-ionic liquid modified glassy carbon electrode and its electrochemical determination
    Xue-Mei Zhan
    Li-Hong Liu
    Zuo-Ning Gao
    Journal of Solid State Electrochemistry, 2011, 15 : 1185 - 1192
  • [43] Modified glassy carbon electrode with Polydopamine-multiwalled carbon nanotubes for simultaneous electrochemical determination of biocompounds in biological fluids
    Shahbakhsh, M.
    Narouie, S.
    Noroozifar, M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 161 : 66 - 72
  • [44] Simultaneous determination of captopril, acetaminophen and tryptophan at a modified electrode based on carbon nanotubes
    Mazloum-Ardakani, Mohammad
    Sheikh-Mohseni, Mohammad Ali
    Mirjalili, Bibi-Fatemeh
    Zamani, Leila
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 686 : 12 - 18
  • [45] Simultaneous voltammetric determination of dopamine and adenosine using a single walled carbon nanotube - Modified glassy carbon electrode
    Goyal, Rajendra N.
    Singh, Sudhanshu P.
    CARBON, 2008, 46 (12) : 1556 - 1562
  • [46] Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes
    Salimi, A
    Hallaj, R
    Khayatian, GR
    ELECTROANALYSIS, 2005, 17 (10) : 873 - 879
  • [47] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of noscapine in biological and pharmaceutical samples
    Rezaei, Behzad
    Zare, S. Zohreh Mirahmadi
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01): : 292 - 299
  • [48] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of leucine in biological and pharmaceutical samples
    Rezaei, B.
    Zare, Z. Mirahmadi
    ANALYTICAL LETTERS, 2008, 41 (12) : 2267 - 2286
  • [49] Simultaneous and selective measurement of dopamine and uric acid using glassy carbon electrodes modified with a complex of gold nanoparticles and multiwall carbon nanotubes
    Wang, Zonghua
    Guo, Huijun
    Gui, Rijun
    Jin, Hui
    Xia, Jianfei
    Zhang, Feifei
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 2069 - 2077
  • [50] Simultaneous determination of ranitidine and metronidazole at glassy carbon electrode modified with single wall carbon nanotubes
    Salimi, Abdollah
    Izadi, Mohadeseh
    Hallaj, Rahman
    Rashidi, Manochehr
    ELECTROANALYSIS, 2007, 19 (16) : 1668 - 1676