Monte Carlo modeling of angiographic optical coherence tomography

被引:18
|
作者
Hartinger, Alzbeta E. [1 ]
Nam, Ahhyun S.
Chico-Calero, Isabel
Vakoc, Benjamin J.
机构
[1] Harvard Univ, Sch Med, Wellman Ctr Photomed, Boston, MA 02114 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2014年 / 5卷 / 12期
基金
美国国家卫生研究院; 加拿大自然科学与工程研究理事会;
关键词
SIMULATION; IMAGES;
D O I
10.1364/BOE.5.004338
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) provides both structural and angiographic imaging modes. Because of its unique capabilities, OCT-based angiography has been increasingly adopted into small animal and human subject imaging. To support the development of the signal and image processing algorithms on which OCT-based angiography depends, we describe here a Monte Carlo-based model of the imaging approach. The model supports arbitrary three-dimensional vascular network geometries and incorporates methods to simulate OCT signal temporal decorrelation. With this model, it will be easier to compare the performance of existing and new angiographic signal processing algorithms, and to quantify the accuracy of vascular segmentation algorithms. The quantitative analysis of key algorithms within OCT-based angiography may, in turn, simplify the selection of algorithms in instrument design and accelerate the pace of new algorithm development. (C) 2014 Optical Society of America
引用
收藏
页码:4338 / 4349
页数:12
相关论文
共 50 条
  • [41] An application of perturbation Monte Carlo in optical tomography
    Heiskala, Juha
    Kotilahti, Kalle
    Nissila, Ilkka
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 274 - 277
  • [42] Congenital retinal macrovessel: angiographic and optical coherence tomography views
    Guyomarch, J.
    Jean-Charles, A.
    Donnio, A.
    Richer, R.
    Acis, D.
    Ventura, E.
    Merle, H.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2008, 31 (03): : 339 - 339
  • [43] VOLUME-RENDERED ANGIOGRAPHIC AND STRUCTURAL OPTICAL COHERENCE TOMOGRAPHY
    Spaide, Richard F.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (11): : 2181 - 2187
  • [44] Optical Coherence Tomography Angiographic Findings in Patients with Posterior Uveitis
    Chen, Ching Jygh
    Burnham, Jordan
    Olson, Matthew
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [45] Origin of improved depth penetration in dual-axis optical coherence tomography: a Monte Carlo study
    Zhao, Yang
    Chu, Kengyeh K.
    Jelly, Evan T.
    Wax, Adam
    JOURNAL OF BIOPHOTONICS, 2019, 12 (06)
  • [46] Monte Carlo simulation of an optical coherence tomography signal -: art. no. 59461P
    Myllylä, R
    Kirillin, M
    Hast, J
    Priezzhev, A
    Optical Materials and Applications, 2005, 5946 : P9461 - P9461
  • [47] Almost Instantaneous Monte Carlo calculation of Optical Coherence Tomography Signal Using Graphic Processing Unit
    Kalra, Anshul
    Lima, Ivan T., Jr.
    Sherif, Sherif S.
    2013 IEEE PHOTONICS CONFERENCE (IPC), 2013, : 12 - 13
  • [48] Identification of layers in optical coherence tomography of skin: comparative analysis of experimental and Monte Carlo simulated images
    Shlivko, I. L.
    Kirillin, M. Yu.
    Donchenko, E. V.
    Ellinsky, D. O.
    Garanina, O. E.
    Neznakhina, M. S.
    Agrba, P. D.
    Kamensky, V. A.
    SKIN RESEARCH AND TECHNOLOGY, 2015, 21 (04) : 419 - 425
  • [49] MCOCT: an experimentally and numerically validated, open-source Monte Carlo simulator for optical coherence tomography
    Erdenedalai, Khaliun
    Maltais-Tariant, Raphael
    Dehaes, Mathieu
    Boudoux, Caroline
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (02) : 624 - 640
  • [50] Contrasting properties of gold nanoparticles for optical coherence tomography:: phantom, in vivo studies and Monte Carlo simulation
    Zagaynova, E. V.
    Shirmanova, M. V.
    Kirillin, M. Yu
    Khlebtsov, B. N.
    Orlova, A. G.
    Balalaeva, I. V.
    Sirotkina, M. A.
    Bugrova, M. L.
    Agrba, P. D.
    Kamensky, V. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (18): : 4995 - 5009