Effects of prone positioning with neck extension on intracranial pressure according to optic nerve sheath diameter measured using ultrasound in children

被引:4
|
作者
Yoon, Soo-Bin [1 ]
Ji, Sang-Hwan [1 ]
Jang, Young-Eun [1 ]
Lee, Ji-Hyun [1 ]
Kim, Eun-Hee [1 ]
Kim, Jin-Tae [2 ]
Kim, Hee-Soo [2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Anesthesiol & Pain Med, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Anesthesiol & Pain Med, 101 Daehak Ro, Seoul 03080, South Korea
关键词
Children; Optic nerve sheath diameter; Prone position; COMPLEX CRANIOSYNOSTOSIS; SINGLE-SUTURE; ULTRASONOGRAPHY; ICP;
D O I
10.1007/s00381-019-04442-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Optic nerve sheath diameter has been used for measure of intracranial pressure. The aim of this study was to evaluate the effect of prone positioning with neck extension on intracranial pressure in infants undergoing craniosynostosis surgery and to determine precautions using optic nerve sheath diameter measurement. Methods We enrolled 30 infants who were scheduled for correction of craniosynostosis in which planning included the prone position with neck extension. Optic nerve sheath diameter (anterior/lateral transbulbar approach) was measured 5 times in each eyeball at the following time points: 15 min after intubation in supine position as the baseline value (supine 1); 10 min after final surgical position before skin incision (prone); and 10 min after returning to supine position at the conclusion of surgery (supine 2). Hemodynamic parameters, airway peak pressure, oxygen saturation, and ETCO2 were monitored. Data were analyzed using repeated-measures multivariate analysis of variance to evaluate the effect of different positions under anesthesia on changes in using optic nerve sheath diameter and P < 0.05 was considered to be statistically significant. Results There was no difference in optic nerve sheath diameter after prone position with neck extension in all the measure. After surgery, optic nerve sheath diameter was decreased compared with the preoperative baseline values (Rt anterior/lateral 5.6/5.5: 5.4/5.2; Lt anterior/lateral 5.6/5.5: 5.4/5.3, P < 0.05, respectively). Conclusions In conclusion, prone positioning with head extension did not further increase intracranial pressure, although the surgical procedure could reduce intracranial pressure in the immediate postoperative period in infants undergoing craniosynostosis surgery.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [31] Effect of neck extension on ultrasonographic optic nerve sheath diameter as a surrogate for intracranial pressure in patients undergoing palatoplasty: A prospective observational study
    Yu, Jihion
    Park, Jun-Young
    Kim, Doo-Hwan
    Koh, Gi-Ho
    Kim, Sungwon
    Hwang, Jai-Hyun
    Oh, Tae Suk
    Kim, Young-Kug
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2020, 73 (02): : 369 - 375
  • [32] Measuring Optic Nerve Sheath Diameter as a Proxy for Intracranial Pressure Reply
    Wang, Li-juan
    Chen, Hong-xiu
    Xing, Ying-qi
    JAMA OPHTHALMOLOGY, 2018, 136 (11) : 1311 - 1312
  • [33] Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure
    Kimberly, Heidi Harbison
    Shah, Sachita
    Marill, Keith
    Noble, Vicki
    ACADEMIC EMERGENCY MEDICINE, 2008, 15 (02) : 201 - 204
  • [34] ULTRASONOGRAPHY OF OPTIC NERVE SHEATH DIAMETER (ONSD) FOR RAISED INTRACRANIAL PRESSURE
    Siddiqui, Naveed Ur Rehman
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 397 - 397
  • [35] Optic Nerve Sheath Diameter Assessment in Patients with Intracranial Pressure Monitoring
    Kavi, Tapan
    Gupta, Anuj
    Hunter, Krystal
    Schreiber, Craig
    Shaikh, Hamza
    Turtz, Alan R.
    CUREUS, 2018, 10 (11):
  • [36] Keep an Eye on the Intracranial Pressure, Thanks to the Optic Nerve Sheath Diameter
    Weinmann, Alexandre Vagh
    Beaucreux, Charlotte
    Kearns, Kevin
    Dubost, Clement
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 22 (06) : 460 - 462
  • [37] Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure
    Amini, Afshin
    Kariman, Hamid
    Dolatabadi, Ali Arhami
    Hatamabadi, Hamid Reza
    Derakhshanfar, Hojjat
    Mansouri, Behnam
    Safari, Saeed
    Eqtesadi, Razie
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (01): : 236 - 239
  • [38] Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection
    Wang Li-Juan
    Chen Hong-Xiu
    Chen Ying
    Yu Ze-Yang
    Xing Ying-Qi
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2020, 7 (05): : 865 - 868
  • [39] Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and its Application to Detect Intracranial Hypertension in Children REPLY
    Fontanel, Liviana
    Pensiero, Stefano
    Ronfani, Luca
    Rosolen, Valentina
    Barbi, Egidio
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 439 - 439
  • [40] Letter: Noninvasive Transorbital Assessment of the Optic Nerve Sheath in Children: Relationship Between Optic Nerve Sheath Diameter, Deformability Index, and Intracranial Pressure
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    OPERATIVE NEUROSURGERY, 2020, 18 (01) : E27 - E28