Analysis of proteomics data: An improved peak alignment approach

被引:1
|
作者
Zhang, Ian [1 ]
Liu, Xueli [2 ]
机构
[1] Pomona Coll, Dept Math, Claremont, CA 91711 USA
[2] City Hope Natl Med Ctr, Div Biostat, Duarte, CA 91010 USA
来源
关键词
Curve alignment; functional data; landmark registration; pairwise; spectrometry data; time warping; SPECTRA; TIME;
D O I
10.1214/14-EJS900E
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Mass spectrometry (MS) data are becoming common recent years. Prior to other statistical inferential procedures, alignment of spectra may be needed to ensure that intensities of the same protein/peptide are accurately located/identified. However, the enormous number of peaks poses challenge in handling such data. Direct applications of available curve alignment methods often do not produce satisfactory results. In this work, we propose an Automated Pairwise Piecewise Landmark Registration (APPLR) method for aligning MS data. For a pair of spectra, the most prominent peaks are given the priority to be aligned first. A weighted Gaussian kernel based similarity score is used to test warp these top peaks and spectra are then aligned according to the best match. The algorithm is implemented in an iterative way until all spectra are aligned. We illustrated the new method and two other curve alignment methods to the unlabeled total ion count data.
引用
收藏
页码:1748 / 1755
页数:8
相关论文
共 50 条
  • [41] Post alignment clustering procedure for comparative quantitative proteomics LC-MS data
    de Groot, Joost C. W.
    Fiers, Mark W. E. J.
    van Ham, Roeland C. H. J.
    America, Antoine H. P.
    PROTEOMICS, 2008, 8 (01) : 32 - 36
  • [42] An Improved Hough Transform-Based Fingerprint Alignment Approach
    Mlambo, Cynthia S.
    Nelwamondo, Fulufhelo V.
    Mathekga, Mmamolatelo E.
    2014 FIRST INTERNATIONAL IMAGE PROCESSING, APPLICATIONS AND SYSTEMS CONFERENCE (IPAS), 2014,
  • [43] Proteomics: data analysis of mass spectrometry results
    Vandenbrouck, Y
    Garin, J
    Jaquinod, M
    Bruley, C
    BIOFUTUR, 2005, (252) : 27 - 31
  • [44] Platforms and Pipelines for Proteomics Data Analysis and Management
    Codrea, Marius Cosmin
    Nahnsen, Sven
    MODERN PROTEOMICS - SAMPLE PREPARATION, ANALYSIS AND PRACTICAL APPLICATIONS, 2016, 919 : 203 - 215
  • [45] Analysis and classification of proteomics data, a case study
    Guzzi, P. H.
    Cannataro, M.
    Gaspari, M.
    Mazza, T.
    Quaresima, B.
    Veltri, P.
    Costanzo, F. S.
    19TH IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2006, : 913 - +
  • [46] Augmenting loop tiling with data alignment for improved cache performance
    Synopsys, Inc, Mountain View, United States
    IEEE Trans Comput, 2 (142-148):
  • [47] A LEVEL SET APPROACH FOR PROTEOMICS IMAGE ANALYSIS
    Savelonas, Michalis
    Mylona, Eleftheria
    Maroulis, Dimitris
    18TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO-2010), 2010, : 1229 - 1233
  • [48] Augmenting loop tiling with data alignment for improved cache performance
    Panda, PR
    Nakamura, H
    Dutt, ND
    Nicolau, A
    IEEE TRANSACTIONS ON COMPUTERS, 1999, 48 (02) : 142 - 149
  • [49] An Improved Method of Data Alignment for Angle Measurement in Monopulse Radar
    Shi, Qingzhan
    Zhang, Deping
    Wei, Kelei
    Yuan, Naichang
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 2211 - 2215
  • [50] Mass spectrometry data analysis in the proteomics era
    Forner, Francesca
    Foster, Leonard J.
    Toppo, Stefano
    CURRENT BIOINFORMATICS, 2007, 2 (01) : 63 - 93