Direct measurement of Vth fluctuation caused by impurity positioning

被引:18
|
作者
Tanaka, T [1 ]
Usuki, T [1 ]
Momiyama, Y [1 ]
Sugii, T [1 ]
机构
[1] Fujitsu Labs Ltd, Quantum Electron Devices Lab, Atsugi, Kanagawa 2430197, Japan
来源
2000 SYMPOSIUM ON VLSI TECHNOLOGY, DIGEST OF TECHNICAL PAPERS | 2000年
关键词
D O I
10.1109/VLSIT.2000.852800
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This paper studies a local fluctuation or channel impurity on the source edge. Our direct measurement successfully separates the local (intra-FET) and global (inter-FET) factors. The quite local region (much less than L-eff X W-eff) significantly affects V-th distribution in a high Sid, which exceeds the global factor in the smallest MOSFETs. The local fluctuation inevitably affects MOSFETs in SRAM is cells even though global fluctuation is reduced by process optimization.
引用
收藏
页码:136 / 137
页数:2
相关论文
共 50 条
  • [21] Analyses of 5σ Vth fluctuation in 65nm-MOSFETs using Takeuchi plot
    Tsunomura, T.
    Nishida, A.
    Yano, F.
    Putra, A. T.
    Takeuchi, K.
    Inaba, S.
    Kamohara, S.
    Terada, K.
    Hiramoto, T.
    Mogami, T.
    2008 SYMPOSIUM ON VLSI TECHNOLOGY, 2008, : 121 - +
  • [22] THE MEASUREMENT OF FUNCTION FLUCTUATION
    GARSIDE, RF
    PSYCHOMETRIKA, 1958, 23 (01) : 75 - 83
  • [23] DIRECT MEASUREMENT OF THE LATTICE AND IMPURITY COMPONENTS OF THE SPIN-LATTICE RELAXATION OF QUADRUPOLE NUCLEI
    EFITSENKO, PY
    MIKUSHEV, VM
    CHARNAYA, EV
    JETP LETTERS, 1991, 54 (10) : 587 - 589
  • [24] A Fast Vth Measurement (FVM) Technique for NBTI Behavior Characterization
    Yu, Xiao
    Cheng, Ran
    Liu, Wei
    Qu, Yiming
    Han, Jinghui
    Chen, Bing
    Lu, Jiwu
    Zhao, Yi
    IEEE ELECTRON DEVICE LETTERS, 2018, 39 (02) : 172 - 175
  • [25] Acute rib fracture caused by preoperative positioning for direct lateral interbody fusion A case report
    Hong, Chang Hwa
    Jung, Ki Jin
    Soh, Jae Wan
    Won, Sung Hun
    Hong, Si John
    Kim, Chang Hyun
    Lee, Hong Seop
    Wang, Soon Do
    Lee, Won Seok
    Kim, Woo Jong
    MEDICINE, 2019, 98 (08)
  • [26] DIRECT COMPUTER POSITIONING
    GERTLER, J
    INSTRUMENT PRACTICE, 1970, 24 (04): : 246 - &
  • [27] PROPERTIES OF AN ANDERSON IMPURITY IN THE LOCAL SPIN FLUCTUATION LIMIT
    SALOMAA, M
    PHYSICA B & C, 1981, 107 (1-3): : 383 - 384
  • [28] Modulated fluctuation of atomic displacement in a crystal with a single impurity
    Peng, F
    PHYSICA B-CONDENSED MATTER, 2006, 373 (02) : 194 - 197
  • [29] FLUCTUATION CONDUCTIVITY OF A SINGLE-IMPURITY KONDO SYSTEM
    AHMED, M
    JOURNAL OF PHYSICS F-METAL PHYSICS, 1978, 8 (07): : L175 - L178