High power factor operation of resonant converters on the utility line

被引:1
|
作者
Bhat, AKS [1 ]
Belaguli, V [1 ]
机构
[1] Univ Victoria, Dept Elect & Comp Engn, Victoria, BC V8W 3P6, Canada
来源
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES | 1997年 / 22卷 / 6期
关键词
resonant converters; power factor; zero-voltage-switching; zero-current-switching;
D O I
10.1007/BF02745843
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Operation and characteristics of resonant converters on the utility line are presented. Series-parallel (LCC-type) resonant converter operating with discontinuous current mode and continuous current mode (variable frequency control as well as fixed-frequency) are considered. Design examples are presented. SPICE simulation and experimental results obtained for the designed converters (rated at 150 W) are presented to verify the theory. It is shown that high line power factor (>0.95) and line current total harmonic distortion (THD) of <25% are obtained for the LCC-type converter for a wide load range (from full load to 10% rated load) without any active control, and the switch peak current decreases with the load current. With active line current control, low distortion and zero voltage switching for the entire cycle are realized.
引用
收藏
页码:733 / 752
页数:20
相关论文
共 50 条
  • [31] Calorimetric Loss Measurements and Optimization of High Power Resonant Converters for Pulsed Applications
    Carastro, F.
    Clare, J. C.
    Bland, M. J.
    Wheeler, P. W.
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 4799 - 4807
  • [32] Resonant converter for high-power-factor rectification
    Forsyth, AJ
    Mollov, SV
    ELECTRONICS LETTERS, 2000, 36 (18) : 1516 - 1518
  • [33] Resonant converter control for high power factor rectification
    Forsyth, AJ
    Mollov, SV
    ELECTRONICS LETTERS, 1997, 33 (24) : 1997 - 1998
  • [34] Power converters for the improved power factor
    不详
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1939, 83 : 371 - 371
  • [35] Adaptive Modulation of Resonant DAB Converters for Wide Range ZVS Operation With Minimum Reactive Circulating Power
    James, Linton David
    Teixeira, Carlos Alberto
    Wilkinson, Richardt H. H.
    McGrath, Brendan P. P.
    Holmes, Donald Grahame
    Riedel, Jan
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (06) : 7396 - 7407
  • [36] Resonant Converters for Electric Equipment Power Supply
    Outeiro, Maria Teresa
    Buja, Giuseppe
    Carvalho, Adriano
    IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 5065 - 5071
  • [37] A comparison of three-phase resonant and PWM converters for high current, high power applications
    Cretu, D
    Dunford, WG
    Edmunds, M
    APEC '97 - TWELFTH ANNUAL APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 1997, : 631 - 637
  • [38] Inductance Cancellation in RF Resonant Power Converters
    Praglin, Max
    Raymond, Luke
    Davila, Juan Rivas
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [39] PWM and PFM Hybrid Control Method for LLC Resonant Converters in High Switching Frequency Operation
    Park, Hwa-Pyeong
    Jung, Jee-Hoon
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (01) : 253 - 263
  • [40] Parallel power regulation techniques for resonant converters
    Carrasco, JA
    Garcia, R
    Ejea, JB
    Dede, EJ
    CIEP 96 - V IEEE INTERNATIONAL POWER ELECTRONICS CONGRESS, TECHNICAL PROCEEDINGS, 1996, : 277 - 281