The assessment of choroidal thickness with spectral-domain optical coherence tomography during Valsalva maneuver

被引:6
|
作者
Cicek, AyseOzkose [1 ]
Duru, Necati [1 ]
Duru, Zeynep [1 ]
Altunel, Orhan [1 ]
Hashas, Arzu Seyhan Karatepe [1 ]
Arifoglu, Hasan Basri [1 ]
Alabay, Bedirhan [1 ]
Atas, Mustafa [1 ]
机构
[1] Kayseri Educ & Res Hosp, Dept Ophthalmol, Kayseri, Turkey
关键词
Valsalva maneuver; EDI-OCT; Choroidal thickness; Autoregulation; Normotensive glaucoma; INTRAOCULAR-PRESSURE CHANGES; BLOOD-FLOW; TENSION GLAUCOMA; OCULAR PRESSURE; AUTOREGULATION; CAT;
D O I
10.1007/s10792-016-0340-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of the study was to evaluate the effect of Valsalva maneuver (VM) on choroidal thickness. All the volunteers underwent a detailed opthalmic examination. Third-generation Spectralis OCT device (software version 5.6.3.0; Spectralis OCT, Heidelberg Engineering, Dossenheim, Germany) was used for assessment. Subfoveal and perifoveal CT of all volunteers were measured by using EDI-OCT technology. Perifoveal CT was measured 1500 A mu m nasally and 1500 A mu m temporally apart from the foveal center. The measurements were repeated while volunteers were performing VM. Sixty-four eyes of 32 healthy volunteers were assessed. The volunteers were aged 29-50. The mean age was 32.8 +/- 6.6 years. Choroidal thickness measurements differed with statistical significance between resting position and VMin all regions (p < 0.001). While mean subfoveal CT was 350.64 +/- 87.73 A mu m during resting position, it was 369.95 +/- 90.12 A mu m during VM (p < 0.001). While mean nasal CT was 292.14 +/- 81.67 A mu m during resting position, it was 305.46 +/- 85.80 A mu m during VM (p < 0.001). While mean temporal CT was 325.93 +/- 80.91 A mu m during resting position, it was 343.21 +/- 81.53 A mu m during VM (p < 0.001). We found statistically significant increase in choroidal thickness during the VM in healthy volunteers. This result might be important for future studies researching autoregulation of choroidal and retinal blood flow in physiologic and pathologic conditions. Also, our study is noteworthy to stand out the errors in EDI-OCT measurements caused by unintentional breath holding of patients.
引用
收藏
页码:843 / 848
页数:6
相关论文
共 50 条
  • [21] Analysis of Spectral-Domain Optical Coherence Tomography in Preterm Children: Retinal Layer Thickness and Choroidal Thickness Profiles
    Park, Kyung-Ah
    Oh, Sei Yeul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (11) : 7201 - 7207
  • [22] Assessment of central retinal thickness, choroidal thickness, and retinal nerve fiber layer in psoriasis: a spectral-domain optical coherence tomography study
    Asena Keles Sahin
    Fatma Etgü
    Aslihan Uzun
    BMC Ophthalmology, 21
  • [23] Assessment of central retinal thickness, choroidal thickness, and retinal nerve fiber layer in psoriasis: a spectral-domain optical coherence tomography study
    Sahin, Asena Keles
    Etgu, Fatma
    Uzun, Aslihan
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [24] Subfoveal Choroidal Thickness in Patients with Chronic Heart Failure Analyzed by Spectral-Domain Optical Coherence Tomography
    Altinkaynak, Hasan
    Kara, Necip
    Sayin, Nihat
    Gunes, Hasan
    Avsar, Sahin
    Yazici, Ahmet Taylan
    CURRENT EYE RESEARCH, 2014, 39 (11) : 1123 - 1128
  • [25] Choroidal Thickness and Volume Mapping by a Six Radial Scan Protocol on Spectral-Domain Optical Coherence Tomography
    Shin, Joong Won
    Shin, Yong Un
    Lee, Byung Ro
    OPHTHALMOLOGY, 2012, 119 (05) : 1017 - 1023
  • [26] Evaluation of choroidal thickness using spectral-domain optical coherence tomography in patients with migraine: a comparative study
    Karalezli, Aylin
    Celik, Guner
    Koktekir, Bengu Ekinci
    Kucukerdonmez, Cem
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2015, 25 (04) : 338 - 342
  • [27] Response to: Choroidal thickness changes ater dynamic exercise as measured by spectral-domain optical coherence tomography
    Sayin, Nihat
    Kara, Necip
    Pekel, Gokhan
    Altinkaynak, Hasan
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (06) : 474 - U98
  • [28] Reproducibility of Peripapillary Choroidal Thickness Measurements with Enhanced Depth Imaging Spectral-Domain Optical Coherence Tomography
    Borba, Paula
    Prado, Vitor
    Silva, Paula
    Matsubara, Igor
    Prata, Tiago
    Vessani, Roberto
    Paranhos, Augusto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [29] Reproducibility of Subfoveal Choroidal Thickness Measurements with Enhanced Depth Imaging by Spectral-Domain Optical Coherence Tomography
    Shao, Lei
    Xu, Liang
    Chen, Chang Xi
    Yang, Li Hong
    Du, Kui Fang
    Wang, Shuang
    Zhou, Jin Qiong
    Wang, Ya Xing
    You, Qi Sheng
    Jonas, Jost B.
    Wei, Wen Bin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) : 230 - 233
  • [30] Choroidal Thickness In and Outside of Vascular Arcade in Healthy Eyes Using Spectral-Domain Optical Coherence Tomography
    Park, Jae Yong
    Kim, Bum Gi
    Hwang, Je Hyung
    Kim, Jae Suk
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (13) : 5819 - 5829