Simplified server model to simulate data center cooling energy consumption

被引:68
|
作者
Ham, Sang-Woo [1 ]
Kim, Min-Hwi [1 ]
Choi, Byung-Nam [2 ]
Jeong, Jae-Weon [1 ]
机构
[1] Hanyang Univ, Div Architectural Engn, Seoul 133791, South Korea
[2] SAMHWA Air Conditioning Engn, Seoul 405818, South Korea
基金
新加坡国家研究基金会;
关键词
Data center; Energy consumption simulation; Server model; Air-side economizer; High ambient temperature; VIABILITY; FLOOR;
D O I
10.1016/j.enbuild.2014.10.058
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper proposes a server model that can be applied to simulating the annual cooling energy consumption of data centers and an analysis of its impact. Recently, aisle containment architecture and the variable air volume system have been widely adopted in the data center industry because of their superior indoor thermal management and cooling energy savings. However, the current simulation method, which fixes the server heat generation and the supply and return air temperature difference of the computer room air handler (CRAH), does not correctly reflect current cooling systems. In this study, a server model was developed that accounts for server thermal characteristics - including server power, fan airflow, and exhaust temperature - according to the given CPU utilization and temperature. After the proposed server model was validated, the annual cooling energy consumption was simulated for modular data centers with an air-side economizer and high ambient temperature. Unlike the conventional method, the proposed model showed that the cooling energy consumption increased when the CRAH supply air temperature was higher than 19 C because of the increase in fan energy consumption. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:328 / 339
页数:12
相关论文
共 50 条
  • [41] Energy Efficient Cooling in Data Center Using Optimization Approach
    Nakamura, Masayuki
    Nakamura, Ryota
    Nishida, Ryuichi
    Takeuchi, Akira
    Tominaga, Tetsuya
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 2103 - 2108
  • [42] Optimized data center site selection—mesoclimatic effects on data center energy consumption and costs
    Dirk Turek
    Peter Radgen
    Energy Efficiency, 2021, 14
  • [43] Cooling the Data Center
    Woods, Andy
    COMMUNICATIONS OF THE ACM, 2010, 53 (04) : 36 - 42
  • [44] Data Center Cooling
    Rutberg, Michael
    Cooperman, Alissa
    Bouza, Antonio
    ASHRAE JOURNAL, 2013, 55 (10) : 82 - 86
  • [45] ECDX: Energy consumption prediction model based on distance correlation and XGBoost for edge data center
    Li, Chuang
    Zhu, Dan
    Hu, Chunhua
    Li, Xiaolong
    Nan, Suqin
    Huang, Hua
    INFORMATION SCIENCES, 2023, 643
  • [46] Data center cooling
    Koplin, EC
    ASHRAE JOURNAL, 2003, 45 (03) : 46 - +
  • [47] Cooling the data center
    Woods A.
    Queue, 2010, 8 (03): : 1 - 10
  • [48] The Power Model of Data Center Server Based on Temporal Convolutional Network
    Zhou, Zhou
    Zhu, Dan
    Li, Chuang
    Nan, Suqin
    Wen, Yanhua
    Beijing Youdian Daxue Xuebao/Journal of Beijing University of Posts and Telecommunications, 2024, 47 (04): : 111 - 116
  • [49] Deep Recurrent Model for Server Load and Performance Prediction in Data Center
    Huang, Zheng
    Peng, Jiajun
    Lian, Huijuan
    Guo, Jie
    Qiu, Weidong
    COMPLEXITY, 2017,
  • [50] Development of an energy evaluation and design tool for dedicated cooling systems of data centers: Sensing data center cooling energy efficiency
    Cho, Jinkyun
    Yang, Joonyoung
    Lee, Changkeun
    Lee, Jinyoung
    ENERGY AND BUILDINGS, 2015, 96 : 357 - 372