Objective To identify characteristics of arterial catheter use, including indwelling times and reasons for removal, and analyze potential risk factors for complications based on patient- and catheter-related variables. Design Prospective clinical study from July 2012 to September 2016. Setting University teaching hospital. Animals One hundred ninety-eight dogs and 29 cats with an arterial catheter monitored in the ICU. Interventions None. Measurements and Main Results A questionnaire was used to obtain patient and catheter information for arterial catheters monitored in the ICU during the study period. Two hundred twenty-seven catheters met the inclusion criteria. Most catheters were placed in the dorsal metatarsal artery in dogs (90.4%) and either the dorsal metatarsal artery (51.7%) or coccygeal artery (48.3%) in cats. Weights ranged from 1.5 to 64 kg in dogs and 0.77 to 8.7 kg in cats. The median indwelling time was 24 hours for dogs and 12 hours for cats. Minor complications occurred in 19.2% of catheters in dogs and 17.2% of those in cats with removal of catheter due to complications in 13 of 198 (6.6%) for dogs and 2 of 29 (6.9%) for cats. There was no association between the incidence of complications and patient weight, catheter indwelling time, species, insertion site, catheter size, or level of consciousness during placement. There was also no association between the method of catheter maintenance (intermittent flushing or continuous pressure transducer) and the failure of a catheter to aspirate or flush. Conclusions Arterial catheter-related complications were relatively frequent, but most complications were minor and did not justify removal of the catheter. This suggests that the use of arterial catheters in both species is relatively safe. However, further research is needed to assess complications related to longer catheter indwelling times, particularly in cats.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 50 条
  • [31] How to improve central venous catheter use in intensive care unit?
    Merrer, J
    Lefrant, JY
    Timsit, JF
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2006, 25 (02): : 180 - 188
  • [32] USE OF CENTRAL VENOUS CATHETER IN PATIENTS HOSPITALIZED IN AN INTENSIVE CARE UNIT
    Gomes de Oliveira, Francisca Jane
    Siqueira, Julianna de Freitas
    Ramos, Islane Costa
    Campos, Francimary de Alencar
    Batista Oria, Monica Oliveira
    Caetano, Joselany Afio
    REVISTA DA REDE DE ENFERMAGEM DO NORDESTE, 2013, 14 (05): : 904 - 910
  • [33] Pulmonary Artery Catheter Use and Mortality in the Cardiac Intensive Care Unit
    Kadosh, Bernard S.
    Berg, David D.
    Bohula, Erin A.
    Park, Jeong-Gun
    Baird-Zars, Vivian M.
    Alviar, Carlos
    Alzate, James
    Barnett, Christopher F.
    Barsness, Gregory W.
    Burke, James
    Chaudhry, Sunit-Preet
    Daniels, Lori B.
    Defilippis, Andrew
    Delicce, Anthony
    Fordyce, Christopher B.
    Ghafghazi, Shahab
    Gidwani, Umesh
    Goldfarb, Michael
    Katz, Jason N.
    Keeley, Ellen C.
    Kenigsberg, Benjamin
    Kontos, Michael C.
    Lawler, Patrick R.
    Leibner, Evan
    Menon, Venu
    Metkus, Thomas S.
    Miller, Elliott
    O'Brien, Connor G.
    Papolos, Alexander I.
    Prasad, Rajnish
    Shah, Kevin S.
    Sinha, Shashank S.
    Snell, R. Jeffrey
    So, Derek
    Solomon, Michael A.
    Ternus, Bradley W.
    Teuteberg, Jeffrey J.
    Toole, Joseph
    van Diepen, Sean
    Morrow, David A.
    Roswell, Robert O.
    JACC-HEART FAILURE, 2023, 11 (08) : 903 - 914
  • [34] Evaluating the Evidence for Midline Catheter Use in the Newborn Intensive Care Unit
    Romesberg, Tricia L.
    JOURNAL OF INFUSION NURSING, 2015, 38 (06) : 420 - 429
  • [35] EFFECT OF CARE BUNDLE IMPLEMENTATION ON CATHETER RELATED BLOODSTREAM INFECTION ON THE INTENSIVE CARE UNIT
    Beckett, P.
    Jerrett, H.
    Pain, T.
    Hermon, A.
    Szakmany, T.
    INTENSIVE CARE MEDICINE, 2010, 36 : S126 - S126
  • [36] Prospective clinical study on the incidence of catheter-related complications in a neurological intensive care unit: 4 years of experience
    Bolis, Denise
    D'Arrigo, Sonia
    Bartesaghi, Alessandro
    Panzeri, Cristina
    Pelegalli, Paola
    Steffanoni, Alberto
    Scoppettuolo, Giancarlo
    Pittiruti, Mauro
    JOURNAL OF VASCULAR ACCESS, 2024, 25 (01): : 100 - 106
  • [37] Arterial catheter-related bloodstream infections: Results of an 8-year survey in a surgical intensive care unit
    Pirracchio, Romain
    Legrand, Matthieu
    Rigon, Mathieu Resche
    Mateo, Joaquim
    Lukaszewicz, Anne Claire
    Mebazaa, Alexandre
    Raskine, Laurent
    Le Pors, Marie Jose Sanson
    Payen, Didier
    CRITICAL CARE MEDICINE, 2011, 39 (06) : 1372 - 1376
  • [38] Tracheostomy Care and Complications in the Intensive Care Unit
    Morris, Linda L.
    Whitmer, Andrea
    McIntosh, Erik
    CRITICAL CARE NURSE, 2013, 33 (05) : 18 - 31
  • [39] Umbilical catheter-associated complications in a level IV neonatal intensive care unit
    Orly L. Levit
    Veronika Shabanova
    Matthew J. Bizzarro
    Journal of Perinatology, 2020, 40 : 573 - 580