Characteristics of arterial catheter use and related complications in dogs and cats in an intensive care unit

被引:10
|
作者
Hagley, Matthew J. [1 ]
Hopper, Kate [2 ]
Epstein, Steven E. [2 ]
机构
[1] Univ Manchester, Fac Biol Med & Hlth, Manchester, Lancs, England
[2] Univ Calif Davis, Dept Vet Surg & Radiol Sci, Sch Vet Med, 2112 Tupper Hall,1 Shields Ave, Davis, CA 95616 USA
关键词
arterial clot; arterial line; blood gas analysis; direct blood pressure; BLOOD PRESSURE MEASUREMENTS; ANESTHETIZED DOGS; INFECTION;
D O I
10.1111/vec.13084
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To identify characteristics of arterial catheter use, including indwelling times and reasons for removal, and analyze potential risk factors for complications based on patient- and catheter-related variables. Design Prospective clinical study from July 2012 to September 2016. Setting University teaching hospital. Animals One hundred ninety-eight dogs and 29 cats with an arterial catheter monitored in the ICU. Interventions None. Measurements and Main Results A questionnaire was used to obtain patient and catheter information for arterial catheters monitored in the ICU during the study period. Two hundred twenty-seven catheters met the inclusion criteria. Most catheters were placed in the dorsal metatarsal artery in dogs (90.4%) and either the dorsal metatarsal artery (51.7%) or coccygeal artery (48.3%) in cats. Weights ranged from 1.5 to 64 kg in dogs and 0.77 to 8.7 kg in cats. The median indwelling time was 24 hours for dogs and 12 hours for cats. Minor complications occurred in 19.2% of catheters in dogs and 17.2% of those in cats with removal of catheter due to complications in 13 of 198 (6.6%) for dogs and 2 of 29 (6.9%) for cats. There was no association between the incidence of complications and patient weight, catheter indwelling time, species, insertion site, catheter size, or level of consciousness during placement. There was also no association between the method of catheter maintenance (intermittent flushing or continuous pressure transducer) and the failure of a catheter to aspirate or flush. Conclusions Arterial catheter-related complications were relatively frequent, but most complications were minor and did not justify removal of the catheter. This suggests that the use of arterial catheters in both species is relatively safe. However, further research is needed to assess complications related to longer catheter indwelling times, particularly in cats.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 50 条
  • [2] Complications of arterial lines in an intensive care unit
    Rodrigues, MG
    Chindamo, A
    Salgado, DR
    Campos, TTP
    Paiva, RN
    Verdeal, JR
    Martins, LC
    INTENSIVE CARE MEDICINE, 2003, 29 : S172 - S172
  • [3] Complications of arterial lines in an intensive care unit
    Guedes, M
    Salgado, D
    Rezende, V
    Paiva, R
    Verdeal, JC
    CRITICAL CARE MEDICINE, 2002, 30 (12) : A61 - A61
  • [4] Complications of arterial lines in an intensive care unit
    MG Rodrigues
    DR Salgado
    RAN Paiva
    VM Resende
    A Chindamo
    JCR Verdeal
    Critical Care, 7 (Suppl 2):
  • [5] Complications of arterial lines in an intensive care unit
    MG Rodrigues
    DR Salgado
    VM Resende
    MVP Negri
    RAN Paiva
    JCR Verdeal
    Critical Care, 7 (Suppl 3):
  • [6] Intravascular catheter complications in the neonatal intensive care unit
    Hermansen, MC
    Hermansen, MG
    CLINICS IN PERINATOLOGY, 2005, 32 (01) : 141 - +
  • [7] Prevention and Management of Dialysis Catheter Complications in the Intensive Care Unit
    Wilson, Patrick
    Lertdumrongluk, Paungpaga
    Leray-Moragues, Helene
    Chenine-Koualef, Leila
    Patrier, Laure
    Canaud, Bernard
    BLOOD PURIFICATION, 2012, 34 (02) : 194 - 199
  • [8] Peripheral arterial catheter securement and catheter survival in the pediatric intensive care unit
    Pilarz, Mary S.
    Walker, Sarah B.
    Rowland, Matthew J.
    JOURNAL OF VASCULAR ACCESS, 2025, 26 (02): : 641 - 645
  • [9] Midline Catheter Use in the Neonatal Intensive Care Unit
    Sykes, Stephanie
    Ulloa, Jodi
    Steward, Deborah
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2024, 36 (01) : 111 - 118
  • [10] DANGER USING PULMONARY ARTERIAL CATHETER IN INTENSIVE-CARE UNIT
    NOBIS, H
    PRACHAR, H
    SPIEL, R
    FEIST, H
    DITTEL, M
    JOBST, C
    KISS, E
    ENENKEL, W
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1977, 107 (45) : 1636 - 1636